The life of a high-pressure convection superheater with damaged coils and a low-pressure superheater of the second stage of a TGMP-314 boiler is analyzed numerically. The dependence of the temperatures of steam, metal, and flue gas at the outlet of the coil banks on the number of plugged coils is established. It is shown that plugging gives rise to sparse banks with overheated coils, high-temperature gas plume that initiates overheating of the downstream tube banks, nonuniform softening of the metal, and reduction of the operational reliability of the superheaters.
Similar content being viewed by others
References
V. A. Bogachev and O. E. Taran, “Influence of thermal nonuniformity on the temperature and reliability of metal of convection superheaters,” Élektr. Stantsii, No. 2, 21 – 24 (2002).
V. A. Bogachev, T. P. Pshechenkova, and M. A. Shumovskaya, “Results of examination of the TGMP-314 boiler superheaters of the power-generating units at Kashira state district power plant using a magnetic ferrite meter,” Therm. Eng., 63(7), 481 – 487 (2016).
SO 34.17.452–98 Standard Instructions. Standard Procedure for Assessing the Remaining Life of Superheaters of Boilers at Power Plants [in Russian], Izd. VTI, Moscow (1998).
A. A. Zhukauskas, Convective Heat Transfer in Heat Exchangers [in Russian], Nauka, Moscow (1982).
B. S. Petukhov, L. G. Genin, and S. A. Kovalev, Heat Exchange in Nuclear Power Units [in Russian], Énergoatomizdat, Moscow (1986).
N. V. Kuznetsov, V. V. Mitor, I. E. Dubovskii, et al., Thermal Design of Boilers (Standard Method ) [in Russian], Énergiya, Moscow (1973).
V. A. Dem’yanov, I. M. Pylev, S. Ya. Il’in, and V. A. Aleksandrov, “Development, at the LMZ, of modified feed pumps for large units of TPPs,” Vestn. YuUrGU, No. 1, 47 – 57 (2005).
N. V. Bugai, T. G. Berezina, and I. I. Trunin, Performance and Durability of Metal of Power Plant Equipment [in Russian], Énergoatomizdat, Moscow (1994).
V. A. Bogachev, V. N. Skorobogatykh, I. A. Shchenkova, T. P. Pshechenkova, and B. E. Shkol’nikova, “Operating characteristics of heat-resistant steels for heating surfaces of a new generation of boilers with supercritical steam parameters,” Power Techn. Eng., 48(6), 297 – 303 (2014).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Élektricheskie Stantsii, No. 12, December 2016, pp. 12 – 17.
Rights and permissions
About this article
Cite this article
Bogachev, V.A., Pshechenkova, T.P. Studying the Dependence of the Life of Convection Superheaters of the Number of Damaged Coils. Power Technol Eng 51, 89–93 (2017). https://doi.org/10.1007/s10749-017-0789-9
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10749-017-0789-9