Abstract
In fires in large compartments like enclosed car parks, airport terminals and industrial halls, the uniform distribution of gas temperature of post-flashover stages are unlikely to occur; in these cases, the thermal actions of a localised fire must be taken into account. In order to design steel structures for a localised fire, very detailed data concerning the development of temperatures in steel is required. EN 1991-1-2 presents a simplified model for calculating the temperatures in ceiling slabs and in the beams that may support such slabs; however, no simplified calculation model for the heat transfer in vertical elements, such as columns, is yet available. There is a need for more experimental data on real scale structures exposed to localised fires. A research project on the evaluation of temperatures in steel columns exposed to localised fires was carried out at the University of Coimbra. Full-scale natural fire tests were used to test columns, instead of conducting the usual furnace tests. This paper presents and discusses the results of the experimental tests on unprotected hollow steel columns exposed to localised fires, each of them simulating a distinct fire scenario according to different fire loads, positions and ventilation conditions. During the fire tests, real measurements showed flame heights and burning times different to those preliminarily estimated: flame heights had been conservatively predicted; while, the duration of the burning had been significantly underestimated.
Similar content being viewed by others
References
ISO 834-1 (1999) Fire-resistance tests—elements of a building construction—part 1: general requirements. BSI: British Standards, London
Lange D, Sjöström J (2014) Mechanical response of a partially restrained column exposed to localised fires. Fire Saf J 67:6782–6795.
EN 1991-1-2 (2002) Eurocode 1—basis of design and actions on structures—part 1–2: actions on structures exposed to fire. CEN, European Committee for Standardization, Brussels
Gales J (2013) Travelling fires and the St. Lawrence Burns project. Fire Technol 50:1535–1543. doi:10.1007/s10694-013-0372-3.
Stern-Gottfried J, Rein G (2012) Travelling fires for structural design—part I: literature review. Fire Saf J 54:74–85.
Hasemi Y (1986) Thermal modelling of upward wall flame spread. Fire Saf Sci 1:87–96.
Haremza C, Santiago A, Simões da Silva L (2013) Design of steel and composite open car parks. Adv Steel Constr 9(4):350–368.
Zhang C, Li GQ, Usmani A (2011) Simulating the behaviour of restrained steel beams to flame impingement from localized-fires. J Constr Steel Res 83:156–165.
Byström A, Sjöström J, Wickström U, Veljkovic M (2012) Large scale test to explore thermal exposure of column exposed to localized fire. In: Structures in fire 12, Zurich, pp 185–194.
Wald F, Chlouba J, Uhlir A, Kallerova P, Stujberova M (2009) Temperatures during fire tests on structure and its prediction according to Eurocodes. Fire Saf J 49:135–146.
Li G, Zhang C (2010) Thermal response of steel columns exposed to localized fires—numerical simulation and comparison with experimental results. In: Proceedings of the sixth international conference on structures in fire 10
Kamikawa D, Hasemi Y, Wakamatsu T, Kagiya K (2003) Experimental flame heat transfer correlations for a steel column adjacent to and surrounded by a pool fire. Fire Saf Sci 7:989–999.
Karlsson B, Quintiere J (2000) Chapter 4—fire plumes and flame heights. In: Enclosure fire dynamics. CRC Press, Boca Raton
Heskestad G (2002) Fire plumes, flame height, and air entrainment. In: DiNenno PJ (ed) Handbook of fire protection engineering, 3rd edn. National Fire Protection Association-NFPA, Society of Fire Protection Engineering-SFPE, Section 2, pp 1–17
EN 1993-1-2 (2005) Eurocode 3—design of steel structures—part 1.2: general rules—structural fire design. CEN, European Committee for Standardization, Brussels
PD 6688-1-2 (2007) Background paper to the UK National Annex to BS EN 1991-1-2. BSI: British Standards, London
Babrauskas V (2002) Heat release rate In: In: DiNenno PJ (ed) Handbook of fire protection engineering, 3rd ed. National Fire Protection Association-NFPA, Society of Fire Protection Engineering-SFPE
Vehicular Access Standards, Parking Standards (1999) Development Control Advice Note 15, 2nd edn, Department of the Environment for Northern Ireland
Acknowledgment
The authors acknowledge the financial support of the Portuguese Foundation for Science and Technology under the research project PTDC/ECM/110807/2009.