Skip to main content
Log in

Thermal aging of cellulosic pressboard material and its surface discharge and chemical characterization

  • Original Paper
  • Published:
Cellulose Aims and scope Submit manuscript

Abstract

Cellulosic pressboard is a key insulation material in oil filled transformers. Surface discharge or partial discharge degrades the insulation material and reduces the life time of the transformer. This study is aimed at understanding the effect of thermal aging of pressboard on the variation of its surface discharge and chemical characteristics. Thermal degradation of pressboard was carried out at 180 °C for 500 h in presence of ester oil under simulated aging conditions. The variation of salient electrical characteristics like surface discharge inception voltage (SDIV), charge measurement and optical emission spectra of the discharges were assessed at different aging periods. A significant reduction in SDIV was observed due to thermal aging. The charge measurement indicated that total charge deposition on pressboard increased with aging duration. Optical emission spectroscopy yielded valuable information regarding the elements evolved during discharge activity. Chemical characterization of the virgin and aged pressboard samples was carried out using analytical pyrolysis coupled with gas chromatograph-mass spectrometric technique (Py-GC/MS). The production of anhydrosugars, furan derivatives and oxygenates from the pressboard increased with aging time, while the esters in the oil were degraded to carboxylic acids with aging. Owing to the weakening of the hydrogen bonding network in oil impregnated pressboard with thermal ageing, high yield of end-chain depropagation products like anhydrosugars was observed during pyrolysis. The weak sites in cellulosic pressboard are expected to act as charge deposition sites.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12

Similar content being viewed by others

References

  • Bertrand Y, Lauzevis P (2013) Development of a low viscosity insulating liquid based on natural esters for distribution transformers. In: 22nd International conference and exhibition on electricity distribution CIRED, pp 1–4

  • Bessant C, Ritchie L, Saini S, Pahlavanpour B, Wilson G (2001) Chemometric evaluation of synchronous scan fluorescence spectroscopy for the determination of regulatory conformance and usage history of insulation oils. Appl Spectrosc 55:840–846

    Article  CAS  Google Scholar 

  • Bhumiwat S, Lowe S, Nething P, Perera J, Wickramasuriya P, Kuansatit P (2010) Performance of oil and paper in transformers based on IEC 61620 and dielectric response techniques. IEEE Electr Insul Mag 26:16–23

    Article  Google Scholar 

  • C57.147-2008—IEEE guide for acceptance and maintenance of natural ester fluids in transformers, pp 24–25

  • Centurioni L, Guastavino F, Torello E (2002) An investigation about the PD degradation of thin polymer films and its correlation with surface charge decay measurements. In: IEEE conf electr insul, pp 371–375

  • CIGRE No 436 (2010) Working group A2.35. Experiences in service with new insulating liquids, p 94. ISBN: 978-2-85873-124-4

  • Cleary GP, Judd MD (2006) UHF and current pulse measurement of partial discharge activity in mineral oil. IEE Proc: Sci Meas Technol 153:47–54

    Google Scholar 

  • Coulibaly ML, Perrier C, Beroual A, Marugan M (2012) Thermal aging of paper and pressboard in mineral and ester oils under air and nitrogen atmospheres. In: IEEE int conf condition monitoring and diagnosis, 23–27 September 2012, Bali, Indonesia, pp 343–346

  • Coulibaly ML, Perrier C, Marugan M, Beroual A (2013) Ageing behaviour of cellulosic materials in presence of mineral oil and ester liquids under various conditions. IEEE Trans Dielectr Electr Insul 20:1971–1976

    Article  Google Scholar 

  • Descoeudres A, Hollenstein Ch, Demellayer R, Walder G (2004) Optical emission spectroscopy of electrical discharge machining plasma. J Phys D Appl Phys 37:875–882

    Article  CAS  Google Scholar 

  • Duran PP, Alvarez-Marino C, Lopez-Fernandez XM (2012) Transformer tertiary stabilizing windings: Part II: overheating hazard on tank walls. In: XXths int conf electr machines, Marseille, France, pp 2369–2374

  • Ganguli TK, Prabhakar MV, Gupta SK, Singh RK, Gopalkrishnan K (2003) Transformers, 2nd edn. Bharat Heavy Electricals Limited. Tata McGraw-Hill Education, pp 34–36

  • Gautam R, Vinu R, Sarathi R, Acharya S, Kumar M, Sharma A (2016) Understanding electrical treeing activity in electron beam irradiated XLPE cable insulation. IEEE Trans Dielectr Electr Insul 23:1652–1662

    Article  CAS  Google Scholar 

  • Han S, Li Q, Li C, Yan J (2014) Electrical and mechanical properties of the oil-paper insulation under stress of the hot spot temperature. IEEE Trans Dielectr Electr Insul 21:179–185

    Article  CAS  Google Scholar 

  • Hill DJT, Le TT, Darveniza M, Saha T (1996) A study of the degradation of cellulosic insulation materials in a power transformer. Part III: degradation products of cellulose insulation paper. Polym Degrad Stab 51:211–218

    Article  CAS  Google Scholar 

  • Hohlein A (2009) Gassing and oxidation behavior of insulating fluids under thermal stress. CIGRE SC D1 colloquium: performance of conventional and new materials for high voltage apparatus, Budapest, Hungary

  • Huang B, Hao M, Hao J, Fu J, Wang Q, Chen G (2016) Space charge characteristics in oil and oil impregnated pressboard and electric field distortion after polarity reversal. IEEE Trans Dielectr Electr Insul 23:881–891

    Article  Google Scholar 

  • IEC publication 60 112 (1972) Recommended method for determining the comparative tracking index of solid insulating material under moist condition, 2nd edn

  • Jadav RB, Ekanayake C, Saha TK (2014) Understanding the impact of moisture and aging of transformer insulation on frequency domain spectroscopy. IEEE Trans Dielectric Electr Insul 21:369–379

    Article  Google Scholar 

  • Judd MD, Farish O (1998) A pulsed GTEM system for UHF sensor calibration. IEEE Trans Instrum Meas 47:875–880

    Article  Google Scholar 

  • Judd MD, Cleary GP, Bennoch CJ (2002) Applying UHF partial discharge detection to power transformers. IEEE Power Eng Rev 22:57–59

    Google Scholar 

  • Khan U, Wang Z, Cotton I (2007) Dissolved gas analysis of alternative fluids for power transformers. IEEE Elect Insul Mag 23:5–14

    Article  Google Scholar 

  • Khawaja RH, Blackburn TR (2009) Impact of high temperature on partial discharges in oil-impregnated insulation. In: Australian universities power eng conf (AUPEC), pp 1–6

  • Li S, Zhao X, Liao R, Yang L, Guo P (2016) Study on aging characteristics of insulating pressboard impregnated by mineral-vegetable oil. Electr Insul Dielectr Phenomena (CEIDP). In: IEEE conference on CEIDP, pp 70–73

  • Liu C, Zhang W, Xu M, Shi L, Zhao Y (2016) A study of aging property of pressboard in gas insulator transformer. In: IEEE int conf dielectr, pp 772–775. doi:10.1109/ICD.2016.7547730

  • McShane CP, Rapp KJ, Corkran JL, Gauger GA, Luksich J (2001) Ageing of paper insulation in natural ester dielectric fluid. In: IEEE PES transmission and distribution conference and exposition, vol 2, pp 675–679

  • Mcshane CP, Rapp KJ, Corkran JL, Gauger GA, Luksich J (2002) Aging of kraft paper in natural ester dielectric fluid. In: Proc of 14th int conf dielectr liq (ICDL), Austria, pp 173–176

  • McShane CP, Luksich. J, Rapp KJ (2003) Retrofilling aging transformers with natural ester based dielectric coolant for safety and life extension. In: IEEE-IAS/PCA cement industry technical conference, Dallas, USA, pp 141–147

  • McShane CP, Corkran J, Rapp KJ, Luksich J (2006) Natural ester dielectric fluid development. In: IEEE PES transmission and distribution conference, pp 18–22

  • Mitchinson PM, Lewin PL, Strawbridge BD, Jarman P (2010) Tracking and surface discharge at the oil-pressboard interface. IEEE Elect Insul Mag 26:35–41

    Article  Google Scholar 

  • Palmer JA, Wang X, Mander A, Torgerson D, Rich C (2000) Effect of aging on the spectral response of transformer oil. In: Conference record of the 2000 IEEE int symp electr insul, Anaheim, CA, USA, pp 460–464

  • Prevost TA (2006) Dielectric properties of natural esters and their influence on transformer insulation system design and performance. In: IEEE PES transmission and distribution conference and exhibition, pp 30–34, doi:10.1109/TDC.2006.1668448

  • Rouse TO (1998) Mineral insulating oil in transformers. IEEE Elect Insul Mag 14:6–16

    Article  Google Scholar 

  • Saha TK, Darveniza M, Yao ZT, Hill DJT, Yeung G (1999) Investigating the effects of oxidation and thermal degradation on electrical and chemical properties of power transformers insulation. IEEE Trans Power Deliv 14:1359–1367

    Article  CAS  Google Scholar 

  • Sahoo A, Gautam R, Vinu R, Jayaganathan R, Sarathi R (2017) Understanding the physico-chemical and surface discharge properties of epoxy silicon carbide nanocomposites. Polym Compos. doi:10.1002/pc.24341

    Google Scholar 

  • Sansonetti JE, Martin WC (2005) Handbook of basic atomic spectroscopic data. J Phys Chem Ref Data 3:1559–2259

    Article  Google Scholar 

  • Sarathi R, Merin Sheema IP (2013) Understanding surface discharge activity in copper sulphide diffused transformer insulation under harmonic AC voltages. In: 2nd Int conf electr power equipment—switching technology (ICEPE-ST), pp 1-4

  • Sarathi R, Merin Sheema IP, Sundararajan J, Danikas DMG (2015) Influence of harmonic AC voltage on surface discharge formation in transformer insulation. IEEE Trans Dielectr Electr Insul 22:2383–2393

    Google Scholar 

  • Singha S, Asano R, Frimpong G, Claiborne CC, Cherry D (2014) Comparative aging characteristics between a high oleic natural ester dielectric liquid and mineral oil. IEEE Trans Dielectr Electr Insul 21:149–158

    Article  CAS  Google Scholar 

  • Taghikhani MA, Gholami A (2009) Heat transfer in power transformer windings with oil-forced cooling. IET Electr Power Appl 3(1):59–66

    Article  Google Scholar 

  • Tsuge S, Ohrani H, Watanabe C (2011) Pyrolysis-GC/MS handbook of synthetic polymers. Elsevier, Oxford

    Google Scholar 

  • Vinu R, Broadbelt LJ (2012) A mechanistic model of fast pyrolysis of glucose-based carbohydrates to predict bio-oil composition. Energy Environ Sci 5:9808–9826

    Article  CAS  Google Scholar 

  • Wooton D (2007) The lubricant’s nemesis—Oxidation. Practicing oil analysis 2007. http://www.machinerylubrication.com/Articles/Print/999. Accessed 1 June 2017

  • Yi Jing, Timoshkin IV, Wilson MP, Given MJ, MacGregor SJ, Tao Wang (2014) Dielectric properties of natural ester, synthetic ester midel 7131 and mineral oil Diala D. IEEE Trans Dielectr Electr Insul 21:644–652

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Sarathi.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Thakur, S., Sarathi, R., Gautam, R. et al. Thermal aging of cellulosic pressboard material and its surface discharge and chemical characterization. Cellulose 24, 5197–5210 (2017). https://doi.org/10.1007/s10570-017-1490-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10570-017-1490-8

Keywords

Navigation