Abstract
The posterior side of the cornea is covered by the endothelial monolayer, which governs corneal transparency but cannot proliferate. Determination of endothelial cell density (ECD) is therefore the minimal and mandatory quality control in all eye banks. It avoids primary graft failures caused by endothelial insufficiency, and allows allocation of corneas to surgical techniques requiring different numbers of endothelial cells (ECs). Corneas stored in organ culture (17% of grafts worldwide), are characterized by heavy stromal swelling and numerous deep endothelial folds, up to 200 µm high. During microscopic en face observation, flat surfaces are thus exceptional and EC counting is biased by parallax errors, resulting in overestimated eye bank ECD (ebECD). We used a motorized transmitted light microscope to acquire Z-stacks of images every 10 µm, and processed them to reconstruct the 3D surface of the folded endothelium. This method (3D-ECD) takes into account the local point-by-point slope in order to correct ECD. On a set of 30 corneas, we compared 3D-ECD and ebECD determined on five identical zones at the center of the cornea. 3D reconstruction allowed us to visualize twice as many cells, and ebECD was 8.1 ± 4.5% (95%CI 6.4–9.7) higher than 3D-ECD, with 1744 ± 488 versus 1606 ± 473 cells/mm2. 3D counting makes it possible to increase cell sampling and to correct overestimation by the conventional en face counting still routinely performed in eye banks.
Similar content being viewed by others
References
Acquart S et al (2010) Endothelial morphometry by image analysis of corneas organ cultured at 31 degrees C. Investig Ophthalmol Vis Sci 51:1356–1364. doi:10.1167/iovs.08-3103
Aguet F, Van De Ville D, Unser M (2008) Model-based 2.5-d deconvolution for extended depth of field in brightfield microscopy. IEEE Trans Image Process Publ IEEE Sign Process Soc 17:1144–1153. doi:10.1109/TIP.2008.924393
Armitage WJ, Dick AD, Bourne WM (2003) Predicting endothelial cell loss and long-term corneal graft survival. Investig Ophthalmol Vis Sci 44:3326–3331
Bernard A, Gavet Y, Hor G, Klossa J, Gauthier AS, Gain P, Thuret G (2016) 3D images of the endothelial surface to increase accuracy of cell count in eye banks. IRBM. doi:10.1016/j.irbm.2016.02.011
Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310
Campolmi N et al (2014) Comparison of endothelial cell density of organ cultured corneas with cornea donor study. Cornea 33:597–603. doi:10.1097/ICO.0000000000000124
Deb-Joardar N, Thuret G, Gavet Y, Acquart S, Garraud O, Egelhoffer H, Gain P (2007a) Reproducibility of endothelial assessment during corneal organ culture: comparison of a computer-assisted analyzer with manual methods. Investig Ophthalmol Vis Sci 48:2062–2067. doi:10.1167/iovs.06-1043
Deb-Joardar N, Thuret G, Zhao M, Acquart S, Peoc’h M, Garraud O, Gain P (2007b) Comparison of two semiautomated methods for evaluating endothelial cells of eye bank corneas. Investig Ophthalmol Vis Sci 48:3077–3082. doi:10.1167/iovs.06-1162
EEBA (2016) European eye bank association directory. Twenty-fourth edition. 2016
Gain P et al (2002a) Automated analyser of organ cultured corneal endothelial mosaic. J Fr Ophtalmol 25:462–472
Gain P et al (2002b) Automated tri-image analysis of stored corneal endothelium. Br J Ophthalmol 86:801–808
Gain P, Jullienne R, He Z, Aldossary M, Acquart S, Cognasse F, Thuret G (2016) Global survey of corneal transplantation and eye banking. JAMA Ophthalmol 134:167–173. doi:10.1001/jamaophthalmol.2015.4776
Gauthier AS et al (2016) Very early endothelial cell loss after penetrating keratoplasty with organ-cultured corneas. Br J Ophthalmol. doi:10.1136/bjophthalmol-2016-309615
Jullienne R, Manoli P, Tiffet T, He Z, Rannou K, Thuret G, Gain P (2015) Corneal endothelium self-healing mathematical model after inadvertent descemetorhexis. J Cataract Refract Surg 41:2313–2318. doi:10.1016/j.jcrs.2015.10.043
Lagali N et al (2010) Donor and recipient endothelial cell population of the transplanted human cornea: a two-dimensional imaging study. Investig Ophthalmol Vis Sci 51:1898–1904. doi:10.1167/iovs.09-4066
Lass JH et al (2010) Endothelial cell density to predict endothelial graft failure after penetrating keratoplasty. Arch Ophthalmol 128:63–69
Nejepinska J, Juklova K, Jirsova K (2010) Organ culture, but not hypothermic storage, facilitates the repair of the corneal endothelium following mechanical damage. Acta Ophthalmol 88:413–419. doi:10.1111/j.1755-3768.2008.01490.x
Price MO, Calhoun P, Kollman C, Price FW, Lass JH (2016) Descemet stripping endothelial keratoplasty. ten-year endothelial cell loss compared with penetrating keratoplasty. Ophthalmology 123:1421–1427
Takahashi Y, Kasahara T (1996) Method for computing morphology of cornea endothelium cells. Google Patents
Terry MA, Shamie N, Chen ES, Hoar KL, Phillips PM, Friend DJ (2008) Endothelial keratoplasty: the influence of preoperative donor endothelial cell densities on dislocation, primary graft failure, and 1-year cell counts. Cornea 27:1131–1137
Acknowledgements
The authors thank Cassandra Dubesset and Chantal Perrache for their technical assistance.
Funding
French National Research Agency for financial support (ANR-12-TECS-004, CorImMo 3D) in partnership with the company Tribvn, Châtillon, France.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jumelle, C., Garcin, T., Gauthier, A.S. et al. Considering 3D topography of endothelial folds to improve cell count of organ cultured corneas. Cell Tissue Bank 18, 185–191 (2017). https://doi.org/10.1007/s10561-017-9624-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10561-017-9624-7