Limitations of Oximetry to Measure Heart Rate Variability Measures

  • Original Paper
  • Published:
Cardiovascular Engineering

Abstract

Measuring heart rate variability (HRV) is widely used to assess autonomic nervous system function. It requires accurate measurement of the interval between successive heartbeats. This can be achieved from recording the electrocardiogram (ECG), which is non-invasive and widely available. However, methodological problems inherent in recording and analyzing ECG traces have motivated a search for alternative means of measuring the interval between successive heartbeats. Recording blood oxygenation pulsations (photoplethysmography—PPG) is also convenient, non-invasive and widely available, and has been suggested as an effective alternative to ECG to derive HRV. Moreover, it has been claimed that the pulse waveforms produced by oximetry may be more practicable than R-R intervals measured from the by ECG, especially for ambulatory recordings. We have therefore compared PPG with ECG recordings to measure HRV applying the same signal analysis techniques to PPG and ECG recordings made simultaneously. Comparison of 5 min recording epochs demonstrated a very high degree of correlation, in temporal, frequency domains and non-linear analysis, between HRV measures derived from the PPG and ECG. However, we found that the PPG signal is especially vulnerable to motion artifacts when compared to the ECG, preventing any HRV analysis at all in a significant minority of PPG recordings. Our results demonstrate that even though PPG provides accurate interpulse intervals to measure heart rate variability under ideal conditions, it is less reliable due to its vulnerability to motion artifacts. Therefore it is unlikely to prove a practical alternative to the ECG in ambulatory recordings or recordings made during other activities.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  • Allen J, Murray A. Age-related changes in the peripheral pulse timing characteristics at the ears, fingers and toes. J Hypertens. 2002;16:711–7.

    CAS  Google Scholar 

  • Bolanos M, Nazeran H, Haltiwanger E. Comparison of heart rate variability signal features derived from electrocardiography and photoplethysmography in healthy individuals. Proc IEEE EMBS, New York, USA; 2006. p. 4289–94.

  • Brennan M, Palaniswami M, Kamen P. Do existing measures of Poincaré plot geometry reflect nonlinear features of heart rate variability. IEEE Trans Biomed Eng. 2001;48:1342–7.

    Article  PubMed  CAS  Google Scholar 

  • Challoner AVJ, Ramsay CA. A photoelectronic plethysmography for the measurement of cutaneous blood flow. Phys Med Biol. 1974;19:317–28.

    Article  PubMed  CAS  Google Scholar 

  • Chang FC, Chang CK, Chiu CC, Hsu SF, Lin YD. Variations of HRV analysis in different approaches. Comput Cardiol. 2007;34:17–20.

    Article  Google Scholar 

  • Chattipakorn N, Incharoen T, Kanlop N, Chattipakorn S. Heart rate variability in myocardial infarction and heart failure. Int J Cardiol. 2007;120:289–96.

    Article  PubMed  Google Scholar 

  • Eithoven W. Die galvanometrische registering des menschlichen electrocardiograms, zugleich eine beurtheilung der anwedung des kapillar-electrometers in physiologie. Pflügers Arch. 1903;99:472–80.

    Article  Google Scholar 

  • Eliakim M, Sapoznikov D, Weinman J. Pulse wave velocity in healthy subjects and in patients with various disease states. Am Heart J. 1971;82:448–57.

    Article  PubMed  CAS  Google Scholar 

  • Enseleit F, Duru F. Long-term continuous external electrocardiographic recording: a review. Europspace. 2006;8:255–66.

    Article  Google Scholar 

  • Ewing DJ, Martyn CN, Young RJ, Clarke BF. The value of cardiovascular autonomic function tests: 10 years experience in diabetes. Diabetes Care. 1985;8:491–8.

    Article  PubMed  CAS  Google Scholar 

  • Foo JYA, Wilson SJ. Detection method to minimize variability in photoplethysmographyic signals for time-related measurement. J Med Eng Technol. 2006;30:93–6.

    Article  PubMed  CAS  Google Scholar 

  • Foo JYA, Wilson SJ, Dakin C, Williams G, Harris MA, Cooper D. Variability in time delay between two models of pulse oximeter for deriving the photoplethysmographic signals. Physiol Meas. 2005a;26:31–44.

    Google Scholar 

  • Foo JYA, Wilson SJ, Bradley AP, Williams G, Harris M, Cooper D. Use of pulse transit time to distinguish respiratory events from tidal breathing in sleeping children. Chest. 2005b;128:3013–9.

    Article  PubMed  Google Scholar 

  • Gil E, Monasterio V, Vergara JM, Laguna P. Pulse photopletismography amplitude decrease detector for sleep apnea evaluation in children. Proc IEEE EMBS, Shanghai, China; 2005. p. 2743–6.

  • Gil E, Mendez MO, Villantieri O, Mateo J, Vergara JM, Bianchi AM, et al. Heart rate variability during pulse photoplethysmography decreased amplitude fluctuations and its correlation with apneic episodes. Comput Cardiol. 2006;33:165–8.

    Google Scholar 

  • Guzzetti S, Rovere MTL, Pinna GD, Maestri R, Borroni E, Porta A, et al. Different spectral components of 24 h heart rate variability are relate to different modes of death in chronic heart failure. Eur Heart J. 2005;26:357–62.

    Article  PubMed  Google Scholar 

  • Han H, Kim MJ, Kim J. Development of a real-time motion artifact reduction algorithm for a wearable photoplethysmography. Proc IEEE EMBS, Lyon, France; 2007. pp. 1538–41.

  • Hertzman AB. Photoeletronic plethysmography of the fingers and toes in man. Proc Soc Exp Biol Med. 1937;37:529–34.

    Google Scholar 

  • Hohnloser SH, Klingenheben T, Zabel M, Li YG. Heart rate variability as an arrhythmia risk stratifier after myocardial infarction. Pacing Clin Electrophysiol. 1997;20:2594–601.

    Article  PubMed  CAS  Google Scholar 

  • Jago JR, Murray A. Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography. Clin Phys Physiol Meas. 1988;9:319–29.

    Article  PubMed  CAS  Google Scholar 

  • Kamal AAR, Harness JB, Irving G, Mearns AJ. Skin photoelectric plethysmography: a review. Comput Meth Prog Bio. 1989;2:257–69.

    Article  Google Scholar 

  • Kudaiberdieva G, Gorenek B, Timuralp B. Heart rate variability as a predictor of sudden cardiac death. Anadolu Kardiyol Derg. 2007;7:68–70.

    PubMed  Google Scholar 

  • Kvernebo K, Megerman J, Hamilton G, Abbott WM. Response of skin photoplethysmography, laser Doppler flowmetry and transcutaneous oxygen tensiometry to stenosis-induced reductions in limb blood flow. Eur J Vasu Surg. 1989;3:113–20.

    Article  CAS  Google Scholar 

  • Lu S, Zhao H, Ju K, Shin K, Shelley MLK, Chon KH. Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information. J Clin Monit Comput. 2008;22:23–9.

    Article  PubMed  Google Scholar 

  • Nitzan M, Babchenko A, Khanokh B, Landau D. The variability of the photoplethysmographic signal-a potential method for the evaluation of the autonomic nervous system. Physiol Meas. 1998;19:93–102.

    Article  PubMed  CAS  Google Scholar 

  • Sandercock GR, Brodie DA. The role of heart rate variability in prognosis for different modes of death in chronic heart failure. Pacing Clin Electrophysiol. 2006;29:892–904.

    Article  PubMed  Google Scholar 

  • Selvaraj N, Jaryal A, Santhosh J, Deepak KK, Anand S. Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography. J Med End Technol. 2008;32:479–84.

    Article  CAS  Google Scholar 

  • So HH, Chan KL. Development of QRS detection method for real-time ambulatory cardiac monitor. Proc IEEE EMBS, Chicago, USA; 1997. p. 289–92.

  • Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Heart rate variability: standards of measurement, physiological interpretation and clinical use. Circulation. 1996;93:1043–65.

    Google Scholar 

  • Tulen JHM, Man in’t Veld AJ, van Steenis HG, Mechelse K. Sleep patterns and blood pressure variability in patients with pure autonomic failure. Clin Auton Res. 1991;1:309–15.

    Article  PubMed  CAS  Google Scholar 

  • Wecht JM, Ronald EDM, Weir JP, Spungen AM, Bauman WA. Cardiac autonomic responses to progressive head-up tilt in individuals with paraplegia. Clin Auton Res. 2003;13:433–8.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Guohua Lu.

Additional information

G. Lu and F. Yang are equally contributed to the work.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lu, G., Yang, F. Limitations of Oximetry to Measure Heart Rate Variability Measures. Cardiovasc Eng 9, 119–125 (2009). https://doi.org/10.1007/s10558-009-9082-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10558-009-9082-3

Keywords

Navigation