Multimodal imaging of a self-expanding transcatheter aortic valve replacement (TAVR) procedure in a reanimated human heart and post-implant analyses

  • Images in CV Applications
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

References

  1. Chinchoy E, Soule CL, Houlton AJ et al (2000) Isolated four-chamber working swine heart model. Ann Thorac Surg 70:1607–1614. https://doi.org/10.1016/S0003-4975(00)01977-9

    Article  CAS  PubMed  Google Scholar 

  2. Hill AJ, Laske TG, Coles JA et al (2005) In vitro studies of human hearts. Ann Thorac Surg 79:168–177. https://doi.org/10.1016/j.athoracsur.2004.06.080

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We acknowledge the gift of this human heart for research from the organ donor/donor family as well as LifeSource for their assistance in organ recovery. We further acknowledge Dr. Brian Bagley and the X-ray Computed Tomography Laboratory in the Department of Earth Sciences, University of Minnesota, for technical assistance in micro-CT imaging. This work was funded by the Institute for Engineering in Medicine at the University of Minnesota and a research contract with Medtronic. CoreValve Evolut™ R is an FDA-approved and market released product in the United States.

Author information

Authors and Affiliations

Authors

Contributions

All authors contributed to the conception, design, and setup of this study. JDZS: Drafted manuscript, created TAVR video, prepared TAVR device and delivery system, imaged heart specimen, reconstruction and modeling, 3D printing. MGB: Edited manuscript and video, selected/implanted TAVR, imaged heart specimen, post-implant imaging analyses. PAI: Final revision and approval of manuscript and video, reanimated heart specimen, implanted TAVR, multimodal imaging of TAVR procedure.

Corresponding author

Correspondence to Paul A. Iaizzo.

Ethics declarations

Conflict of interest

PA Iaizzo has a research contract and education consultant arrangement with Medtronic. MG Bateman has ownership interest in Medtronic. JD Zhingre Sanchez has no conflicts of interest to declare.

Ethical approval

This article does not contain any studies with human participants or animals performed by any of the authors.

Informed consent

LifeSource secured consent from the organ donor’s family to use this heart for research.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary file1 (MP4 195213 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhingre Sanchez, J.D., Bateman, M.G. & Iaizzo, P.A. Multimodal imaging of a self-expanding transcatheter aortic valve replacement (TAVR) procedure in a reanimated human heart and post-implant analyses. Int J Cardiovasc Imaging 35, 2135–2137 (2019). https://doi.org/10.1007/s10554-019-01645-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-019-01645-2

Navigation