Skip to main content
Log in

Radiation exposure and coronary artery calcium scans in the society for heart attack prevention and eradication cohort

  • Original Paper
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

Coronary artery calcium (CAC) scoring is used in asymptomatic patients to improve their clinically predicted risk for future cardiovascular events. Current CT protocols seek to reduce radiation exposure without diminishing image quality. Reported radiation exposure remains widely variable (0.8–5 mSv) depending on the type of protocol. In this study, we report the radiation exposure of CAC scoring from the Society for Heart Attack Prevention and Eradication (SHAPE) early detection program cohort sites, which spanned multiple centers using 64-MDCT (multi-detector computed tomography) scanners. We reviewed radiation exposure in milliSieverts (mSv) for 82,214 participants from the SHAPE early detection program cohort who underwent CAC scoring. This occurred over a 2.5-year period (2012–2014) divided among 33 sites in 7 countries with four different types 64-MDCT scanners. The effective radiation dose was reported as mSv. Mean radiation dosing amongst all 82,214 participants was 1.03 mSv, a median dose of 0.94 mSv. The mean radiation dose ranged from 0.76 to 1.31 mSv across the 33 sites involved with the SHAPE program cohort. Subgroup analysis by age, gender or body mass index (BMI) less than 30 kg/m2 showed no variability. Radiation dose in patients with BMI > 30 kg/m2 were significantly greater than other subgroups (µ = 1.96 mSv, p < 0.001). The use of 64-MDCT scanners and protocols provide the effective radiation dose for CAC scoring, which is approximately 1 mSv. This is consistently lower than previously reported for CAC scanning, regardless of scanner type, age or gender. In contrast, a greater BMI influenced mean radiation doses.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Detrano R, Guerci AD, Carr JJ, Bild DE, Burke G, Folsom AR, Liu K, Shea S, Szklo M, Bluemke DA, O’Leary DH, Tracy R, Watson K, Wong ND, Kronmal RA (2008) Coronary calcium as a predictor of coronary events in four racial or ethnic groups. N Engl J Med 358(13):1336–1345

    Article  CAS  PubMed  Google Scholar 

  2. Greenland P, Alpert JS, Beller GA, Benjamin EJ, Budoff MJ, Fayad ZA, Foster E, Hlatky MA, Hodgson JM, Kushner FG, Lauer MS, Shaw LJ, Smith SC Jr, Taylor AJ, Weintraub WS, Wenger NK (2010) 2010 ACCF/AHA guideline for assessment of cardiovascular risk in asymptomatic adults: a report of the american college of cardiology foundation/american heart association task force on practice guidelines. J Am Coll Cardiol 56:50–103

    Article  Google Scholar 

  3. Stone NJ, Robinson J, Lichtenstein AH, Bairey Merz CN, Blum CB, Eckel RH, Goldberg AC, Gordon D, Levy D, Lloyd-Jones DM, McBride P, Schwartz JS, Shero ST, Smith SC Jr, Watson K, Wilson PWF (2014) ACC/AHA guideline on the treatment of blood cholesterol to reduce atherosclerotic cardiovascular risk in adults: a report of the American College of Cardiology/American Heart Association task force on practice guidelines. J Am Coll Cardiol 63(25 Pt B):2889–2934

    Article  PubMed  Google Scholar 

  4. Kim KP, Einstein AJ, Berrington de González A (2009) Coronary artery calcification screening: estimated radiation dose and cancer risk. Arch Intern Med 169:1188–1194

    Article  PubMed  PubMed Central  Google Scholar 

  5. Messenger B, Li D, Nasir K, Carr JJ, Blankstein R, Budoff MJ (2016) Coronary calcium scans and radiation exposure in the multi-ethnic study of atherosclerosis. Int J Cardiovasc Imaging 32(3): 525–529

    Article  PubMed  Google Scholar 

  6. Shope TB, Gagne RM, Johnson GC (1981) A method for describing the doses delivered by transmission X-ray computed tomography. Med Phys 8(4):488–495

    Article  CAS  PubMed  Google Scholar 

  7. Hunold P, Vogt FM, Schmermund A, Debatin JF, Kerkhoff G, Budde T et al (2003) Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology 226(1):145–152

    Article  PubMed  Google Scholar 

  8. Budoff MJ, Achenbach S, Blumenthal RS, Carr JJ, Goldin JG, Greenland P, Guerci AD, Lima JA, Rader DJ, Rubin GD, Shaw LJ, Wiegers SE, American Heart Association Committee on Cardiovascular Imaging and Intervention; American Heart Association Council on Cardiovascular Radiology and Intervention; American Heart Association Committee on Cardiac Imaging, Council on Clinical Cardiology (2006) Assessment of coronary artery disease by cardiac computed tomography: a scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology. Circulation 114(16):1761–1791

    Article  PubMed  Google Scholar 

  9. Voros S, Rivera JJ, Berman DS, Blankstein R, Budoff MJ, Cury RC, Desai MY, Dey D, Halliburton SS, Hecht HS, Nasir K, Santos RD, Shapiro MD, Taylor AJ, Valeti US, Young PM, Weissman G (2011) Guideline for minimizing radiation exposure during acquisition of coronary artery calcium scans with the use of multidetector computed tomography: a report by the Society for Atherosclerosis Imaging and Prevention Tomographic Imaging and Prevention Councils in collaboration with the Society of Cardiovascular Computed Tomography. Society for Atherosclerosis Imaging and Prevention Tomographic Imaging and Prevention Councils; Society of Cardiovascular Computed Tomography. J Cardiovasc Comput Tomogr 5(2):75–83

    Article  PubMed  Google Scholar 

  10. Baron KB, Choi AD, Chen MY (2016) Low radiation dose calcium scoring: evidence and techniques. Curr Cardiovasc Imaging Rep 9:12

    Article  PubMed  PubMed Central  Google Scholar 

  11. Gerber TC, Gibbons RJ (2010) Weighing the risks and benefits of cardiac imaging with ionizing radiation. JACC Cardiovasc Imaging 3:528–535

    Article  PubMed  Google Scholar 

  12. Gerber T, Carr J, Arai A, Dixon R, Ferrari V, Gomes A, Heller G, McCollough C, McNitt-Gray M, Mettler F, Mieres J, Morin R, Yester M (2009) Ionizing radiation in cardiac imaging: a science advisory from the AHA committee on cardiac imaging of the council on clinical cardiology and committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention. Circulation 119(7):1056–1065

    Article  PubMed  Google Scholar 

  13. Budoff M (2009) Maximizing dose reductions with CT. Int J Cardiovasc Imaging 25:279–287

    Article  Google Scholar 

  14. Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH et al (2009) Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 361(9):849–857

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  15. Budoff MJ, Hokanson JE, Nasir K, Shaw LJ, Kinney GL, Chow D, Demoss D, Nuguri V, Nabavi V, Ratakonda R, Berman DS, Raggi P (2010) Progression of coronary artery calcium predicts all-cause mortality. JACC Cardiovasc Imaging 3(12):1229–1236

    Article  PubMed  Google Scholar 

  16. Ceponiene I, Nakanishi R, Osawa K, Kanisawa M, Nezarat N, Rahmani S, Kissel K, Kim M, Jayawardena E, Broersen A, Kitslaar P, Budoff MJ (2017) Coronary artery calcium progression is associated with coronary plaque volume progression: results from a quantitative semiautomated coronary artery plaque analysis. JACC Cardiovasc Imaging. https://doi.org/10.1016/j.jcmg.2017.07.023

    Article  PubMed  Google Scholar 

  17. Budoff MJ, Young R, Lopez VA, Kronmal RA, Nasir K, Blumenthal RS, Detrano RC, Bild DE, Guerci AD, Liu K, Shea S, Szklo M, Post W, Lima J, Bertoni A, Wong ND (2013) Progression of coronary calcium and incident coronary heart disease events: the multi-ethnic study of atherosclerosis. J Am Coll Cardiol 61(12):1231–1239

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  18. McCollough CH, Primak AN, Braun N, Kofler J, Yu L, Christner J (2009) Strategies for reducing radiation dose in CT. Radiol Clin North Am 47(1):27–40

    Article  PubMed  PubMed Central  Google Scholar 

  19. Earls JP, Berman EL, Urban BA, Curry CA, Lane JL, Jennings RS et al (2008) Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246:742–753

    Article  PubMed  Google Scholar 

  20. Choi TY, Malpeso J, Li D, Sourayanezhad S, Budoff MJ (2011) Radiation dose reduction with increasing utilization of prospective gating in 64-multidetector cardiac computed tomography angiography. J Cardiovasc Comput Tomogr 5(4):264–270

    Article  PubMed  Google Scholar 

  21. Nakazato R, Dey D, Gutstein A, Le ML, Cheng VY, Pimentel R, Paz W, Hayes SW, Thomson LE, Friedman JD, Berman DS (2009) Coronary artery calcium scoring using a reduced tube voltage and radiation dose protocol with dual-source computed tomography. J Cardiovasc Comput Tomogr 3:394–400

    Article  PubMed  Google Scholar 

  22. Marwan M, Mettin C, Pflederer T, Seltmann M, Schuhback A, Muschiol G et al (2013) Very low-dose coronary artery calcium scanning with high-pitch spiral acquisition mode: comparison between 120-kV and 100-kV tube voltage protocols. J Cardiovasc Comput Tomogr 7:32–38

    Article  PubMed  Google Scholar 

  23. Halliburton SS, Abbara S, Chen MY, Gentry R, Mahesh M, Raff GL, Shaw LJ, Hausleiter J (2011) Society of cardiovascular computed tomography. SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT. J Cardiovasc Comput Tomogr 5(4):198–224

    Article  PubMed  PubMed Central  Google Scholar 

  24. Bittencourt MS, Schmidt B, Seltmann M, Muschiol G, Ropers D, Daniel WG, Achenbach S (2011) Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience. Int J Cardiovasc Imaging 27(7):1081–7

    Article  PubMed  Google Scholar 

  25. Gosling O, Loader R, Venables P, Rowles N, Morgan-Hughes G, Roobottom C (2010) Cardiac CT: are we underestimating the dose? A radiation dose study utilizing the 2007 ICRP tissue weighting factors and a cardiac specific scan volume. Clin Radiol 65:1013–1017

    Article  CAS  PubMed  Google Scholar 

  26. Trattner S, Halliburton S, Thompson CM et al (2018) Cardiac-specific conversion factors to estimate radiation effective dose from dose-length product in computed tomography. J Am Coll Cardiol Imaging 11(1):64–74

    Article  Google Scholar 

  27. ICRP Publication 103 (2007) The 2007 recommendations of the international commission on radiological protection. Ann ICRP 37:1–332

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Matthew J. Budoff.

Ethics declarations

Conflict of interest

Matthew Budoff has received research grants from General Electric. No other author has conflicts of interest.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Research involving human and animal rights

This article does not contain any studies with animals performed by any of the authors.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Patel, A.A., Fine, J., Naghavi, M. et al. Radiation exposure and coronary artery calcium scans in the society for heart attack prevention and eradication cohort. Int J Cardiovasc Imaging 35, 179–183 (2019). https://doi.org/10.1007/s10554-018-1431-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-018-1431-0

Keywords

Navigation