Feasibility of measurements of valve dimensions in en-face-3D transesophageal echocardiography

  • Original Paper
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

Newest 3D software allows measurements directly in the en-face-3D TEE mode. Aim of the study was to ascertain whether measurements performed in the en-face-3D TEE mode are comparable with conventional measurement methods based on 2D TEE and 3D using the multiple plane reconstruction mode with the Qlab® software. En-face-3D TEE is used more frequently in daily clinical routine during cardiac operations. So far measurements could only be done based on 2D images or with the use of multi planar reconstruction mode with additional software. Measurement directly in the 3D image (en-face-3D TEE) would make measurements faster and easier to use in clinical practice. After approval by the local ethic committee and written informed consent from the patients additionally to a comprehensive perioperative 2D TEE examination a real time (RT) 3D zoom- dataset was recorded. Routine measurements of the length of anterior and posterior mitral valve leaflets as well as mitral valve and aortic valve areas were performed in en-face-3D TEE, multiplanar reconstruction mode using Qlab®-software (Philips, Netherlands) and 2D TEE standard views. Twenty nine patients with a mean age of 67 years undergoing elective cardiac surgery/interventions were enrolled in this study. Direct measurements in en-face-3D TEE mode lead to non significant underestimation of all parameters as compared to Qlab® and 2D TEE measurements. Measurements in en-face-3D TEE are feasible but lead to non significant underestimation compared to measurements performed with Qlab® or in 2D TEE views.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

Abbreviations

CV:

Chamber view

TEE:

Transesophageal echocardiography

2D:

Two dimensional

3D:

Three dimensional

RT:

Real time

AV:

Aortic valve

MV:

Mitral valve

AML:

Anterior mitral leaflet

PML:

Posterior mitral leaflet

AVA:

Aortic valve area

MVA:

Mitral valve area

pts:

Patients

References

  1. Lang RM, Tsang W, Weinert L, Mor-Avi V, Chandra S (2011) Valvular heart disease. The value of 3-dimensional echocardiography. J Am Coll Cardiol 58(19):1933–1944. doi:10.1016/j.jacc.2011.07.035

    Article  PubMed  Google Scholar 

  2. Lang RM, Badano LP, Tsang W, Adams DH, Agricola E, Buck T, Faletra FF, Franke A, Hung J, de Isla LP, Kamp O, Kasprzak JD, Lancellotti P, Marwick TH, McCulloch ML, Monaghan MJ, Nihoyannopoulos P, Pandian NG, Pellikka PA, Pepi M, Roberson DA, Shernan SK, Shirali GS, Sugeng L, Ten Cate FJ, Vannan MA, Zamorano JL, Zoghbi WA, American Society of E, European Association of E (2012) EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography. Eur Heart J Cardiovasc Imaging 13(1):1–46. doi:10.1093/ehjci/jer316

    Article  PubMed  Google Scholar 

  3. Zamorano J, Cordeiro P, Sugeng L, Perez de Isla L, Weinert L, Macaya C, Rodriguez E, Lang RM (2004) Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation: an accurate and novel approach. J Am Coll Cardiol 43(11):2091–2096. doi:10.1016/j.jacc.2004.01.046

    Article  PubMed  Google Scholar 

  4. Matsumura Y, Fukuda S, Tran H, Greenberg NL, Agler DA, Wada N, Toyono M, Thomas JD, Shiota T (2008) Geometry of the proximal isovelocity surface area in mitral regurgitation by 3-dimensional color Doppler echocardiography: difference between functional mitral regurgitation and prolapse regurgitation. Am Heart J 155(2):231–238. doi:10.1016/j.ahj.2007.09.002

    Article  PubMed  Google Scholar 

  5. Cheng TO, Xie MX, Wang XF, Wang Y, Lu Q (2004) Real-time 3-dimensional echocardiography in assessing atrial and ventricular septal defects: an echocardiographic-surgical correlative study. Am Heart J 148(6):1091–1095. doi:10.1016/j.ahj.2004.05.050

    Article  PubMed  Google Scholar 

  6. Mukherjee C, Tschernich H, Kaisers UX, Eibel S, Seeburger J, Ender J (2011) Real-time three-dimensional echocardiographic assessment of mitral valve: Is it really superior to 2D transesophageal echocardiography? Ann Card Anaesth 14(2):91–96. doi:10.4103/0971-9784.81562

    Article  PubMed  Google Scholar 

  7. Grewal J, Mankad S, Freeman WK, Click RL, Suri RM, Abel MD, Oh JK, Pellikka PA, Nesbitt GC, Syed I, Mulvagh SL, Miller FA (2009) Real-time three-dimensional transesophageal echocardiography in the intraoperative assessment of mitral valve disease. J Am Soc Echocardiogr 22(1):34–41. doi:10.1016/j.echo.2008.11.008

    Article  PubMed  Google Scholar 

  8. Agricola E, Oppizzi M, Pisani M, Maisano F, Margonato A (2008) Accuracy of real-time 3D echocardiography in the evaluation of functional anatomy of mitral regurgitation. Int J Cardiol 127(3):342–349. doi:10.1016/j.ijcard.2007.05.010

    Article  PubMed  Google Scholar 

  9. Ender A, Eibel S, Hasheminejad E, Scholz M, Kaisers UX, Mukherjee C, Ender J (2012) Real-time 3 dimensional full volume data set : benefits in problem focused intraoperative transesophageal echocardiography. Anaesthesist 61(10):875–882. doi:10.1007/s00101-012-2088-z

    Article  CAS  PubMed  Google Scholar 

  10. Shanewise JS, Cheung AT, Aronson S, Stewart WJ, Weiss RL, Mark JB, Savage RM, Sears-Rogan P, Mathew JP, Quinones MA, Cahalan MK, Savino JS (1999) ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiography examination: recommendations of the American Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. Anesth Analg 89(4):870–884

    Article  CAS  PubMed  Google Scholar 

  11. Feneck R, Kneeshaw J, Fox K, Bettex D, Erb J, Flaschkampf F, Guarracino F, Ranucci M, Seeberger M, Sloth E, Tschernich H, Wouters P, Zamorano J (2010) Recommendations for reporting perioperative transoesophageal echo studies. Eur J Echocardiogr 11(5):387–393. doi:10.1093/ejechocard/jeq043

    Article  PubMed  Google Scholar 

  12. Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310

    Article  CAS  PubMed  Google Scholar 

  13. Maslow A, Mahmood F, Poppas A, Singh A (2014) Three-dimensional echocardiographic assessment of the repaired mitral valve. J Cardiothorac Vasc Anesth 28(1):11–17. doi:10.1053/j.jvca.2013.05.007

    Article  PubMed  Google Scholar 

  14. Grewal J, Suri R, Mankad S, Tanaka A, Mahoney DW, Schaff HV, Miller FA, Enriquez-Sarano M (2010) Mitral annular dynamics in myxomatous valve disease: new insights with real-time 3-dimensional echocardiography. Circulation 121(12):1423–1431. doi:10.1161/CIRCULATIONAHA.109.901181

    Article  PubMed  Google Scholar 

  15. Baumgartner H, Hung J, Bermejo J, Chambers JB, Evangelista A, Griffin BP, Iung B, Otto CM, Pellikka PA, Quinones M (2009) Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. Eur J Echocardiogr 10(1):1–25. doi:10.1093/ejechocard/jen303

    Article  PubMed  Google Scholar 

  16. Giannopoulos AA, Steigner ML, George E, Barile M, Hunsaker AR, Rybicki FJ, Mitsouras D (2016) Cardiothoracic Applications of 3-dimensional Printing. J Thorac Imaging 31(5):253–272. doi:10.1097/RTI.0000000000000217

    Article  PubMed  PubMed Central  Google Scholar 

  17. Hien MD, Rauch H, Lichtenberg A, De Simone R, Weimer M, Ponta OA, Rosendal C (2013) Real-time three-dimensional transesophageal echocardiography: improvements in intraoperative mitral valve imaging. Anesth Analg 116(2):287–295. doi:10.1213/ANE.0b013e318262e154

    Article  PubMed  Google Scholar 

  18. Hung J, Lang R, Flachskampf F, Shernan SK, McCulloch ML, Adams DB, Thomas J, Vannan M, Ryan T, Ase (2007) 3D echocardiography: a review of the current status and future directions. J Am Soc Echocardiogr 20(3):213–233. doi:10.1016/j.echo.2007.01.010

    Article  PubMed  Google Scholar 

  19. Noack T, Mukherjee C, Kiefer P, Emrich F, Vollroth M, Ionasec RI, Voigt I, Houle H, Ender J, Misfeld M, Mohr FW, Seeburger J (2015) Four-dimensional modelling of the mitral valve by real-time 3D transoesophageal echocardiography: proof of concept. Interact Cardiovasc Thorac Surg 20(2):200–208. doi:10.1093/icvts/ivu357

    Article  PubMed  Google Scholar 

  20. Zamorano JL, Badano LP, Bruce C, Chan KL, Goncalves A, Hahn RT, Keane MG, La Canna G, Monaghan MJ, Nihoyannopoulos P, Silvestry FE, Vanoverschelde JL, Gillam LD (2011) EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. J Am Soc Echocardiogr 24(9):937–965. doi:10.1016/j.echo.2011.07.003

    Article  PubMed  Google Scholar 

  21. Lang RM, Badano LP, Tsang W, Adams DH, Agricola E, Buck T, Faletra FF, Franke A, Hung J, de Isla LP, Kamp O, Kasprzak JD, Lancellotti P, Marwick TH, McCulloch ML, Monaghan MJ, Nihoyannopoulos P, Pandian NG, Pellikka PA, Pepi M, Roberson DA, Shernan SK, Shirali GS, Sugeng L, Ten Cate FJ, Vannan MA, Zamorano JL, Zoghbi WA, American Society of E, European Association of E (2012) EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography. J Am Soc Echocardiogr 25(1):3–46. doi:10.1016/j.echo.2011.11.010

    Article  PubMed  Google Scholar 

  22. Morbach C, Lin BA, Sugeng L (2014) Clinical application of three-dimensional echocardiography. Prog Cardiovasc Dis 57(1):19–31. doi:10.1016/j.pcad.2014.05.005

    Article  PubMed  Google Scholar 

  23. Guarracino F, Baldassarri R, Ferro B, Giannini C, Bertini P, Petronio AS, Di B, V, Landoni G, Alfieri O (2014) Transesophageal echocardiography during MitraClip(R) procedure. Anesth Analg 118(6):1188–1196. doi:10.1213/ANE.0000000000000215

    Article  PubMed  Google Scholar 

  24. Ender J, Sgouropoulou S (2013) Value of transesophageal echocardiography (TEE) guidance in minimally invasive mitral valve surgery. Ann Cardiothorac Surg 2(6):796–802. doi:10.3978/j.issn.2225-319X.2013.10.09

    PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Joerg Ender.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

After approval by the local ethics committee and written informed consent was received, 29 patients undergoing elective cardiac surgery and interventional cardiac procedures were enrolled in this study. This study has been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Eibel, S., Turton, E., Mukherjee, C. et al. Feasibility of measurements of valve dimensions in en-face-3D transesophageal echocardiography. Int J Cardiovasc Imaging 33, 1503–1511 (2017). https://doi.org/10.1007/s10554-017-1141-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-017-1141-z

Keywords

Navigation