Abstract
We investigated a novel sequence with radial k-space sampling, gridding and sliding window reconstruction with bSSFP contrast that allows for true real-time functional cardiac evaluation independent from respiration and ECG triggering. 12 healthy volunteers underwent 1.5 T cardiac MRI. Single-shot short axis views were acquired with a) standard retrospectively ECG-gated segmented breath-hold (bh) bSSFP and with the real-time radial bSSFP sequence with a nominal temporal resolution of b) 16 fps (frames per second) and c) 40 fps. Radial bSSFP were acquired during free breathing without ECG synchronization. Left ventricular functional parameters (EDV, ESV, SV and EF) were compared and quality of wall motion depiction was assessed. Contrast-to-noise-ratio (CNR) of myocardium/blood pool in the left ventricle was calculated. EF showed excellent correlation (Bland-Altman r = 0.99; Lin rho = 0.91) between bh-bSSFP (65 %) and 40 fps radial (64 %) and moderate correlation (r = 0.84, rho = 0.20) with 16 fps radial bSSFP (56 %). While EDV was in good agreement for all three sequences, ESV was significantly overestimated with 16 fps radial bSSFP. Despite lower CNR, image quality for wall motion assessment was rated significantly better for 40 fps compared to 16 fps radial bSSFP due to the faster temporal resolution. Left ventricular functional analysis with fast true real-time radial bSSFP is in good agreement with standard ECG-gated bh-bSSFP. The independency from ECG synchronization and breathing promises a robust method for patients with impaired cardiopulmonary status in whom breath-hold and good quality ECG cannot be achieved.
Similar content being viewed by others
References
Semelka RC, Tomei E, Wagner S et al (2004) Interstudy reproducibility of dimensional and functional measurements between cine magnetic resonance studies in the morphologically abnormal left ventricle. Am Heart J 119:1367–1373
Van Rossum AC, Visser FC, Sprenger M, Van Eenige MJ, Valk J, Roos JP (1988) Evaluation of magnetic resonance imaging for determination of left ventricular ejection fraction and comparison with angiography. Am J Cardiol 62:628–633
White HD, Norris RM, Brown MA, Brandt PW, Whitlock RM, Wild CJ (1987) Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 76:44–51
Hamer AW, Takayama M, Abraham KA et al (1994) End-systolic volume and long-term survival after coronary artery bypass graft surgery in patients with impaired left ventricular function. Circulation 90:2899–2904
Marks B, Mitchell DG, Simelaro JP (1997) Breath-holding in healthy and pulmonary-compromised populations: effects of hyperventilation and oxygen inspiration. J Magn Reson Imaging 7:595–597
Zhang S, Block KT, Frahm J (2010) Magnetic resonance imaging in real time: advances using radial FLASH. J Magn Reson Imaging 31:101–109
Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 219:264–269
Barkhausen J, Goyen M, Ruhm SG, Eggebrecht H, Debatin JF, Ladd ME (2002) Assessment of ventricular function with single breath-hold real-time steady-state free precession cine MR imaging. AJR Am J Roentgenol 178:731–735
Lee VS, Resnick D, Bundy JM, Simonetti OP, Lee P, Weinreb JC (2002) Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precession. Radiology 222:835–842
Nassenstein K, Eberle H, Maderwald S et al (2010) Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine. Eur Radiol 20:2341–2347
Wintersperger BJ, Sincleair S, Runge VM et al (2007) Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function. Eur Radiol 17:73–80
Bellenger NG, Gatehouse PD, Rajappan K, Keegan J, Firmin DN, Pennell DJ (2000) Left ventricular quantification in heart failure by cardiovascular MR using prospective respiratory navigator gating: comparison with breath-hold acquisition. J Magn Reson Imaging 11:411–417
Buehrer M, Curcic J, Boesiger P, Kozerke S (2008) Prospective self-gating for simultaneous compensation of cardiac and respiratory motion. Magn Reson Med 60:683–690
Larson AC, Kellman P, Arai A et al (2005) Preliminary investigation of respiratory self-gating for free-breathing segmented cine MRI. Magn Reson Med 53:159–168
Manka R, Buehrer M, Boesiger P, Fleck E, Kozerke S (2010) Performance of simultaneous cardiac-respiratory self-gated three-dimensional MR imaging of the heart: initial experience. Radiology 255:909–916
Peters DC, Nezafat R, Eggers H, Stehning C, Manning WJ (2008) 2D free-breathing dual navigator-gated cardiac function validated against the 2D breath-hold acquisition. J Magn Reson Imaging 28:773–777
Pipe JG (1999) Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 42:963–969
Hori Y, Yamada N, Higashi M, Hirai N, Nakatani S (2003) Rapid evaluation of right and left ventricular function and mass using real-time true-FISP cine MR imaging without breath-hold: comparison with segmented true-FISP cine MR imaging with breath-hold. J Cardiovasc Magn Reson 5:439–450
Kuhl HP, Spuentrup E, Wall A et al (2004) Assessment of myocardial function with interactive non-breath-hold real-time MR imaging: comparison with echocardiography and breath-hold Cine MR imaging. Radiology 231:198–207
Uecker M, Zhang S, Frahm J (2010) Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH. Magn Reson Med 63:1456–1462
Zhang S, Uecker M, Voit D, Merboldt KD, Frahm J (2010) Real-time cardiovascular magnetic resonance at high temporal resolution: radial FLASH with nonlinear inverse reconstruction. J Cardiovasc Magn Reson 12:39
Uecker M, Zhang S, Voit D, Karaus A, Merboldt KD, Frahm J (2010) Real-time MRI at a resolution of 20 ms. NMR Biomed 23:986–994
Conflict of interest
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bauer, R.W., Radtke, I., Block, K.T. et al. True real-time cardiac MRI in free breathing without ECG synchronization using a novel sequence with radial k-space sampling and balanced SSFP contrast mode. Int J Cardiovasc Imaging 29, 1059–1067 (2013). https://doi.org/10.1007/s10554-013-0183-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10554-013-0183-0