Abstract
One major motivation for microfluidic research is to develop point of care diagnostic tools, which often demands a solution for chip-scale pumping that is of low cost, small size and light weight. Electrokinetics has been extensively studied for disposable pumping since only electrodes are needed to induce microflows. However, it encounters difficulties with conductive biofluids because of the associated high salt content. In electrokinetic pumps, electrodes are in direct contact with fluid, so high salt content will compress the electric double layer that is essential to electroosmostic flows. Alternating current electrothermal (ACET) effect is the only electrokinetic method found viable for biofluid actuation. While high frequency (>10 kHz) operation can suppress electrochemical reactions, electrical potential that could be applied over biofluids is still limited within several volts due to risk of electrolysis or impedance mismatch. Since ACET flow velocity has a quartic dependence on the voltage, ACET flows would be rather slow if electric field alone is used for actuation. This work studies the effect of a thermal bias on enhancing AC electrokinetic pumping. With proper imposition of external thermal gradients, significant improvement in flow velocity has been demonstrated by numerical simulation and preliminary experiments. Both showed that with 4 Vrms at 100 kHz, flow velocity increased from ~10 μm/s when there was no thermal biasing to ~112 μm/s when a heat flux was applied.
Similar content being viewed by others
References
A.B.D. Brown, C.G. Smith, A.R. Rennie, Pumping of water with ac electric fields applied to asymmetric pairs of microelectrodes. Phys. Rev. E 63, 016305 (2001)
A. Castellanos, A. Ramos, A. Gonźalez, N.G. Green, H. Morgan, Electrohydrodynamics and dielectrophoresis in microsystems: scaling laws. J. Phys. D: Appl. Phys. 36, 2584–2597 (2003)
D.R. Lide (ed.), CRC Handbook of Chemistry and Physics, 92nd edn. (CRC Press, London, 2011–2012), pp 5–74 and 6–187
E. Du, S. Manoochehri, Microfluidic pumping optimization in microgrooved channels with ac electrothermal actuations. Appl. Phys. Lett. 96, 034102 (2010)
A. Gonzalez, A. Ramos, H. Morgan, N.G. Green, A. Castellanos, Electrothermal flows generated by alternating and rotating electric fields in Microsystems. J. Fluid Mech. 564, 415–433 (2006)
N.G. Green, A. Ramos, A. Gonzalez, H. Morgan, A. Castellanos, Fluid flow induced by nonuniform ac electric fields in electrolytes on microelectrodes. I. Experimental measurements. Phys. Rev. E 61, 4011–18 (2000a)
N.G. Green, A. Ramos, A. Gonzalez, A. Castellanos, H. Morgan, Electric field induced fluid flow on microelectrodes: the effect of illumination. J. Phys. D: Appl. Phys. 33, L13–L17 (2000b)
N.G. Green, A. Ramos, A. Gonzalez, A. Castellanos, H. Morgan, Electrothermally induced fluid flow on microelectrodes. J. Electrost. 53, 71–87 (2001)
D. Lastochkin, R. Zhou, P. Wang, Y. Ben, H.-C. Chang, Electrokinetic micropump and micromixer design based on AC faradaic polarization. J. Appl. Phys. 96, 1730 (2004)
M. Lian, J. Wu, Microfluidic flow reversal at low frequency by AC electrothermal effect. Microfluid. Nanofluid. 7(6), 757–765 (2009a)
M. Lian, J. Wu, Ultra fast micropumping by biased AC electrokinetics. Appl. Phys. Lett. 94, 064101 (2009b)
M. Lian, N. Islam, J. Wu, AC electrothermal manipulation of conductive fluids and particles for Lab-chip applications. IET Nanobiotechnol. 1(3), 36–43 (2007)
M.P. Hughes AC electrokinetics: applications for nanotechnology. Nanotechnology. 11, 124–132 (2000)
W.Y. Ng, S. Goh, Y.C. Lam, C. Yang, I. Rodríguez, DC-biased AC-electroosmotic and AC-electrothermal flow mixing in microchannels. Lab. Chip 9, 802–809 (2009)
I.R. Perch-Nielsen, N.G. Green, A. Wolff, Numerical simulation of traveling wave induced electrothermal fluid flow. J. Phys. D: Appl. Phys. 37, 2323–2330 (2004)
A. Ramos, A. Gonzalez, A. Castellanos, N.G. Green, H. Morgan, Pumping of liquids with AC voltages applied to asymmetric pairs of microelectrodes. Phys. Rev. E 67, 056302 (2003)
M. Sigurdson, D. Wang, C.D. Meinhart, Electrothermal stirring for heterogeneous immunoassays. Lab. Chip 5, 1366–1373 (2005)
V. Studer, A. Pepin, Y. Chen, A. Ajdari, An integrated AC electrokinetic pump in a microfluidic loop for fast and tunable flow control. Analyst 129, 944–949 (2004)
J. Wu, Interactions of electrical fields with fluids: laboratory-on-a-chip applications. IET Nanobiotechnol 2(1), 14–27 (2008a)
J. Wu, AC electroosmotic micropump by asymmetric electrode polarization, J. Appl. Phys. 103, 024907 (2008b)
J. Wu, M. Lian, K. Yang, Micropumping of biofluids by AC electrothermal effects. Appl. Phys. Lett. 90, 234103 (2007)
Acknowledgments
This study was supported by the U.S. National Science Foundation under Grant No. ECS-0448896. Micro fabrication of this research was conducted at the Center for Nanophase Materials Sciences, which is sponsored at Oak Ridge National Laboratory by the Scientific User Facilities Division, U.S. Department of Energy.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
(WMV 6325 kb)
(WMV 1567 kb)
(WMV 4231 kb)
(WMV 4396 kb)
(WMV 3419 kb)
Rights and permissions
About this article
Cite this article
Yuan, Q., Wu, J. Thermally biased AC electrokinetic pumping effect for Lab-on-a-chip based delivery of biofluids. Biomed Microdevices 15, 125–133 (2013). https://doi.org/10.1007/s10544-012-9694-z
Published:
Issue Date: