Skip to main content
Log in

Fabrication and testing of a PDMS multi-stacked hand-operated LOC for use in portable immunosensing systems

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript

Abstract

This paper presents the development of a reliable multi-liquid lab-on-a-chip (LOC), with a hand-operated mechanism, for the application in portable immunosensing systems. To control the transport of multiple liquids without any external equipment, we utilize capillary attraction force for filling and surface tension for stopping liquid flow. As a driving force, hydraulic pressure caused by the elastic deformation of a liquid reservoir transfers liquid stopped at passive valves. The proposed LOC successfully demonstrates a reliable sequential liquid transfer within the reaction channel. To highlight its feasibility as a portable diagnostic system, we performed the electrochemical immunoassay measuring antibody concentrations within the fabricated LOC. As a test biorecognition reaction, the anti-dinitrophenyl (DNP) antibody with an enzymatic catalysis was selected as the target analyte. The amplified signals obtained from this experiment indicated a high selectivity of the immunosensing LOC.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13

Similar content being viewed by others

Reference

  • C.H. Ahn, J.W. Choi, G. Beaucage, J.H. Nevin, J.B. Lee, A. Puntambekar, J.Y. Lee, Proc. IEEE. 92, 154–173 (2004)

    Article  Google Scholar 

  • P.E. Andreotti, G.V. Ludwig, A.H. Peruski, J.J. Tuite, S.S. Mores, L.F. Peruski Jr, Biotechniques. 35, 850–859 (2003)

    Google Scholar 

  • P.A. Auroux, D. Iossifidis, D.R. Reyes, A. Manz, Anal. Chem. 74, 2637 (2002)

    Article  Google Scholar 

  • A. Bange, H.B. halsall, W.R. Heineman, Biosens. Bioelctron. 20, 2488–2503 (2005)

    Article  Google Scholar 

  • T.D. Boone, H.H. Hooper, D.S. Soane, In Solid State Sensor and Actuator Workshop ‘98 in Hilton Head Island (South Carolina, 1998)

  • T. Cuvand, C. Ho, Phys. Fluids. 16, 4575–4585 (2004)

    Article  Google Scholar 

  • F. Darain, D.S. Park, J.S. Park, Y.B. Shim, Biosens. Bioelectron. 19, 1245–1252 (2004)

    Article  Google Scholar 

  • H. Dong, C.M. Li, Y. Zhang, X. Cao, Y. Gan, Lab Chip. 7, 1752–1758 (2007)

    Article  Google Scholar 

  • C.L. Feng, Y.H. Xu, L.M. Song, Sens. Actuators, B. 66, 190–192 (2000)

    Article  Google Scholar 

  • M.J. Fuerstman, A. Lai, M.E. Thurlow, S.S. Shevkoplyas, H.A. Stone, G.M. Whitesides, Lab Chip. 7, 1479–1489 (2007)

    Article  Google Scholar 

  • K. Haubert, T. Drier, D. Beebe, Lab Chip. 6, 1548–1549 (2006)

    Article  Google Scholar 

  • C.C. Hong, J.W. Choi, C. Ahn, in Technical Digest. MEMS 2002 IEEE International Conference (Las Vegas, NV, USA, 2002), 240–243

  • J. Khandurina, A. Guttman, J. Chromatogr. A. 943, 159 (2002)

    Article  Google Scholar 

  • N. Kim, I.S. Park, D.K. Kim, Sens. Actuators, B. 100, 432–438 (2004)

    Article  Google Scholar 

  • J.S. Ko, H.C. Yoon, H. Yang, H.B. Pyo, K.H. Chung, S.J. Kim, Y.T. Kim, Lab Chip. 3, 106–113 (2003)

    Article  Google Scholar 

  • H.S. Ko, S.S. Yang, J.S. Yoo, H.J. Kim, KIEE J. Electr. Eng. Technol. 1, 387–395 (2006)

    Google Scholar 

  • J.H. Lee, S.S. Yang, B.W. Kim, S.J. Sim, H. Chae, H.C. Yoon, Colloids Surf., A. 313–314, 509–514 (2008)

    Article  Google Scholar 

  • A. Mata, A. Fleischman, S. Roy, Biomed. Microdevices. 7, 281–293 (2005)

    Article  Google Scholar 

  • J.C. McDonald, D.C. Duffy, J.R. Anderson, D.T. Chiu, H. Wu, O.J. Schueller, G.M. Whitesides, Electrophoresis. 21, 27–40 (2000)

    Article  Google Scholar 

  • J. Moorthy, G.A. Mensing, D. Kim, S. Mohanty, D.T. Eddington, W.H. Tepp, E.A. Johnson, D.J. Beebe, Electrophoresis. 25, 1705–1713 (2004)

    Article  Google Scholar 

  • B.K. Oh, Y.K. Kim, K.W. Park, W.H. Lee, J.W. Choi, Anal. Chem. 75, 1497–1504 (2004)

    Google Scholar 

  • S.W. Park, J.H. Lee, H.C. Yoon, S.S. Yang, BioChip. J. 1, 35–42 (2007)

    Google Scholar 

  • B. Samel, V. Nock, A. Russom, P. Griss, G. Stemme, Biomed. Microdevices. 9, 61–67 (2007)

    Article  Google Scholar 

  • S.K. Sia, V. Linder, B.A. Parviz, A. Diegel, G.M. Whitesides, Angew. Chem. Int. Ed. 43, 498–502 (2004)

    Article  Google Scholar 

  • B.Y. Won, H.G. Choi, K.H. Kim, S.Y. Byun, H.S. Kim, H.C. Yoon, Biotechnol. Bioeng. 89, 816–821 (2005)

    Article  Google Scholar 

Download references

Acknowledgements

This work was supported by a grant (No. RTI04-03-05) from the Regional Technology Innovation Program of the Ministry of Commerce, Industry and Energy (MOCIE).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sang Sik Yang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Park, S.W., Lee, J.H., Yoon, H.C. et al. Fabrication and testing of a PDMS multi-stacked hand-operated LOC for use in portable immunosensing systems. Biomed Microdevices 10, 859–868 (2008). https://doi.org/10.1007/s10544-008-9200-9

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10544-008-9200-9

Keywords

Navigation