Abstract
We demonstrated a novel micro Coulter counter featuring platinum-black electrodes for human blood cell counting application. Two designs of micro Coulter counter were fabricated using two distinct technologies: integrated parylene and soft lithography. Platinum-black enhanced detection in the intermediate frequency range (∼100 Hz to 7 MHz), which is the operation frequency suitable for sensing the cells flowing by the electrodes. A detailed theoretical modeling of the sensing mechanism has been performed for the design of the electrodes, and electrical impedance spectra measurements confirmed the theoretical model. The surface morphology and roughness of the platinum black electroplated surface were characterized by SEM and AFM measurements. Polystyrene beads of various sizes were initially used to validate the operation of the devices, and using excitation frequency of 10 kHz, the signal magnitude was found to be correlated with the volume of the individual bead. Human blood cell sensing was successfully demonstrated with diluted whole blood and leukocyte rich plasma under the same excitation frequency. The histogram of impedance magnitude of the cells matched well with volume distributions of erythrocytes and leukocytes measured by conventional counting techniques. Micro Coulter counters have the advantages of small foot-print, low sample volume, and reduced cost of operation. Further development of the devices can lead to the development of a highly-sensitive and high-throughput handheld blood counting system for point-of-care applications.
Similar content being viewed by others
References
K. Asami, Prog. Polym. Sci. 27(8), 1617–1659 (2002)
H.E. Ayliffe, A.B. Frazier, R.D. Rabbitt, J. Microelectromech Syst 8(1), 50–57 (1999)
E. Barsoukov, J.R. Macdonald, Impedance Spectroscopy Theory, Experiment, and Applications, 2nd edn. (Wiley, Hoboken, NJ (2005)
L.J. Breckenridge, R.J.A. Wilson, P. Connolly, A.S.G. Curtis, J.A.T. Dow, S.E. Blackshaw, C.D.W. Wilkinson, J. Neurosci. Res. 42(2), 266–276 (1995)
C.D. Chin, V. Linder, S.K. Sia, Lab Chip 7(1), 41–57 (2007)
H.G. Chun, T.D. Chung, H.C. Kim, Anal. Chem. 77(8), 2490–2495 (2005)
W.H. Coulter, US Patent 2,656,508 (1953)
W.H. Coulter, W.R. Hogo, US Patent 3,502,974 (1970)
A.M. Feltham, M. Spiro, Chem. Rev 71(2), 177–193 (1971)
S. Gawad, L. Schild, P. Renaud, Lab Chip 1(1), 76(2001)
S. Gawad, K. Cheung, U. Seger, A. Bertsch, P. Renaud, Lab Chip 4(3), 241–251 (2004)
B. George-Gay, K. Parker, J. Perianesth. Nurs. 18(2), 96–117 (2003)
D.C. Grahame, Chem. Rev. 41(3), 441–501 (1947)
C.H. Hsu, F. Mansfeld, Corrosion 57(9), 747–748 (2001)
B. Ilic, D. Czaplewski, P. Neuzil, T. Stanczyk, J. Blough, G.J. Maclay, J. Mater. Sci. 35(14), 3447–3457 (2000)
J.-B. Jorcin, M.E. Orazem, N. Pebere, B. Tribollet, Electrochim. Acta 51(8–9), 1473–1479 (2006)
D.R. Jung, D.S. Cuttino, J.J. Pancrazio, P. Manos, T. Cluster, R.S. Sathanoori, L.E. Aloi, M.G. Coulombe, M.A. Czamaski, D.A. Borkholder, G.T.A. Kovacs, P. Bey, D.A. Stenger, J.J. Hickman, J. Vac. Sci. Technol., A, Vac. Surf. Films 16(3), 1183–1188 (1998)
F. Kohlrausch, L. Holborn, (Leipzig: Teubner, 1898)
W. Lang, K. Kuhl, H. Sandmaier, Sens. Actuators, A, Phys. 34(3), 243–248 (1992)
D.W. Lee, S. Yi, Y.-H. Cho, 18th IEEE International Conference on Micro Electro Mechanical Systems (MEMS2005). (Miami Beach, Florida, USA, 2005).
M.P. Maher, J. Pine, J. Wright, Y.C. Tai, J. Neurosci. Methods 87(1), 45–56 (1999)
C.A. Marrese, Anal. Chem. 59(1), 217–218 (1987)
M. Mazumdar, K.L. Kussmaul, Biometrics 23(4), 671–684 (1967)
S.B. McKenzie, Clinical Laboratory Hematology (Prentice Hall, Upper Saddle River, NJ (2004)
W.H. Mulder, J.H. Sluyters, T. Pajkossy, L. Nyikos, J. Electroanal. Chem. 285(1–2), 103–115 (1990)
J.H. Nieuwenhuis, F. Kohl, J. Bastemeijer, P.M. Sarro, M.J. Vellekoop, Sens. Actuators, B, Chem. 102(1), 44 (2004)
H. Oka, K. Shimono, R. Ogawa, H. Sugihara, M. Taketani, J. Neurosci. Methods 93(1), 61–67 (1999)
S.R. Quake, A. Scherer, Science 290(5496), 1536–1540 (2000)
D.A. Robinson, Proc Inst Electr Electron Eng 56(6), 1065–1081 (1968)
D. Satake, H. Ebi, N. Oku, K. Matsuda, H. Takao, M. Ashiki, M. Ishida, Sens. Actuators, B, Chem. 83(1–3), 77 (2002)
W. Schmickler, Chem. Rev. 96(8), 3177–3200 (1996)
H.P. Schwan, Ann. Biomed. Eng 20(3), 269–288 (1992)
M. Toner, D. Irimia, Annu. Rev. Biomed. Eng. 7, 77–103 (2005)
G.M. Whitesides, Nature 442(7101), 368–373 (2006)
J. Xie, Y.N. Miao, J. Shih, Q. He, J. Liu, Y.C. Tai, T.D. Lee, Anal. Chem. 76(13), 3756–3763 (2004)
P. Yager, T. Edwards, E. Fu, K. Helton, K. Nelson, M.R. Tam, B.H. Weigl, Nature 442(7101), 412–418 (2006)
P. Zoltowski, J. Electroanal. Chem. 443(1), 149–154 (1998)
Acknowledgement
This work is supported by the National Space Biomedical Research Institute through NASA NCC 9–58. The authors would like to thank other members of the Caltech Micromachining Laboratory for their valuable assistance.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zheng, S., Liu, M. & Tai, YC. Micro coulter counters with platinum black electroplated electrodes for human blood cell sensing. Biomed Microdevices 10, 221–231 (2008). https://doi.org/10.1007/s10544-007-9128-5
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10544-007-9128-5