A Dynamic Tonometer for Measuring Intraocular Pressure

  • Published:
Biomedical Engineering Aims and scope

The principle of action of a dynamic tonometer for measuring intraocular pressure is considered. It is based on monitoring of the oscillation period of the dynamic system of tonometer elements and the eye. A model of the tonometer-eye oscillation system is presented. The effect of eye elements (eyelid and cornea) on the oscillation period of the system is considered. An example of practical implementation of this system is given.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. P. Nesterov, A. Ya. Bunin, and L. A. Katsnel’son, Intraocular Pressure [in Russian], Nauka, Moscow (1974).

    Google Scholar 

  2. O. L. Golovkov, “A Method for Measuring Intraocular Pressure through Eyelid and Device for Its Implementation (Versions)”, RF Patent No. 2335234 (2008).

  3. S. P. Timoshenko, Vibration Problems in Engineering [Russian translation], Nauka, Moscow (1955).

    Google Scholar 

  4. E. N. Iomdina, Sovr. Probl. Biomekh., 11, 183-200 (2006).

    Google Scholar 

  5. P. I. Begun, Modeling and Biomechanics [in Russian], Vysshaya Shkola, Moscow (2004).

    Google Scholar 

  6. S. P. Timoshenko and S. Voinovskii-Kriger, Membranes and Shells [Russian translation], Nauka, Moscow (1966).

    Google Scholar 

  7. Strength, Durability, Vibrations: Handbook, Vol. 3 [in Russian], Mashinostroenie, Moscow (1968).

  8. G. A. Lyubimov, Glaucoma, No. 1, 43-49 (2006).

  9. www.vseozrenii.ru/zrenie/vse_o_zrenii/eye_anatomy/eyelids_chapter.php

  10. zrenue.com/anatomija-glaza/33-veki/333-klinicheskaja-anatomi-ja-vek.html

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. I. Dikin.

Additional information

Translated from Meditsinskaya Tekhnika, Vol. 47, No. 3, May-Jun., 2013, pp. 18-20.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Dikin, V.I., Ivanyschev, C.V., Kornev, N.P. et al. A Dynamic Tonometer for Measuring Intraocular Pressure. Biomed Eng 47, 130–133 (2013). https://doi.org/10.1007/s10527-013-9351-8

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10527-013-9351-8

Keywords

Navigation