Skip to main content
Log in

Seismic behaviour of masonry buildings built of low compressive strength units

  • Original Research
  • Published:
Bulletin of Earthquake Engineering Aims and scope Submit manuscript

Abstract

Seismic behaviour of masonry buildings, built of low compressive strength units, is discussed. Although such materials have already been tested and approved for use from mechanical and thermal insulation point of view, the knowledge regarding their structural behaviour is still lacking. In order to investigate the resistance and deformation capacity of this particular type of masonry construction in seismic conditions, a series of eight walls and model of a two-storey full scale confined masonry building have been tested by subjecting the specimens to cyclic shear loads. All tests were conducted under a combination of constant vertical load and quasi static, cyclically imposed horizontal load. The behaviour of tested specimens was of typical shear type. Compared with the behaviour of plain masonry walls, the presence of tie-columns resulted into higher resistance and displacement capacity, as well as smaller lateral resistance degradation. The response of the model was determined by storey mechanism with predominant shear behaviour of the walls and failure mechanism of the same type as in the case of individual confined masonry walls. Adequate seismic behaviour of this particular masonry structural type can be expected under the condition that the buildings are built as confined masonry system with limited number of stories.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fig. 22

Similar content being viewed by others

References

  • Alcocer SM, Meli R (1995) Test program on the seismic behavior of confined masonry walls. Mason Soc J 13:68–76

    Google Scholar 

  • Bernardini A, Modena C, Turnšek V, Vescovi U (1980) A comparison of three laboratory test methods used to determine the shear resistance of masonry walls. In: Proceedings of the 7th world conference on earthquake engineering, vol 7. International Association for Earthquake Engineering, Istanbul, pp 181–184

  • CEN (1999) Methods of test for masonry. In: Determination of compressive strength. EN 1052-1:1999. Bruxelles

  • CEN (2004) Eurocode 8: design of structures for earthquake resistance—part 1: general rules, seismic actions and rules for buildings, EN 1998-1. Bruxelles

  • CEN (2005) Eurocode 6: design of masonry structures—part 1-1: general rules for buildings—rules for reinforced and unreinforced masonry, EN 1996-1-1. Bruxelles

  • CEN (2011) Specification for masonry units. Clay masonry units. EN 771-1:2011 + A1:2015. Bruxelles

  • Faustino J, Silva E, Pinto J, Soares E, Cunha VMCF, Soares S (2015) Lightweight concrete masonry units based in processed granulate of corn cob as aggregate. Mater Constr 65:318. https://doi.org/10.3989/mc.2015.04514

    Article  Google Scholar 

  • ISO (2016) ISO 6892-1:2016. Metallic materials—tensile testing—part 1: method of test at room temperature

  • Mueller A, Schnell A, Ruebner K (2015) The manufacture of lightweight aggregates from recycled masonry rubble. Constr Build Mater 98:376–387. https://doi.org/10.1016/j.conbuildmat.2015.07.027

    Article  Google Scholar 

  • SIST (2005) - Eurocode 8: design of structures for earthquake resistance—part 1: general rules, seismic actions and rules for buildings—National Annex, SIST EN 1998-1:2005/A101:2006. Ljubljana, Slovenia

  • Tomaževič M (1978) Improvement of computer program POR. Report ZRMK-IK, Ljubljana (in Slovene)

  • Tomaževič M (2007) Damage as a measure for earthquake-resistant design of masonry structures: Slovenian experience. Can J Civ Eng 34(11):1403–1412

    Article  Google Scholar 

  • Tomaževič M (2009) Shear resistance of masonry walls and Eurocode 6: shear versus tensile strength of masonry. Mater Struct 42(17):889–907

    Article  Google Scholar 

  • Tomaževič M, Klemenc I (1997) Seismic behaviour of confined masonry walls. Earthq Eng Struct Dyn 26:1059–1072

    Article  Google Scholar 

  • Turnšek V, Čačovič F (1971) Some experimental results on the strength of brick masonry walls. In: Proceedings 2nd international brick-masonry conference. British Ceramic Society, Stoke-on-Trent, pp 149–156

  • Turnšek V, Sheppard P (1980) The shear and flexural resistance of masonry walls. In: Proceedings of the international research conference on earthquake engineering. Skopje, pp 517–568

  • Umek A (1971) Comparison between unreinforced, confined and horizontally reinforced masonry walls. Civ Eng 20:241–248

    Google Scholar 

Download references

Acknowledgements

The research presented in this article was carried out within the framework of research Project J2-6749, financed by the Slovenian Research Agency and a research Project, supported by Lafarge Cement d.o.o., Slovenia.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Petra Triller.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Triller, P., Tomaževič, M. & Gams, M. Seismic behaviour of masonry buildings built of low compressive strength units. Bull Earthquake Eng 16, 6191–6219 (2018). https://doi.org/10.1007/s10518-018-0418-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10518-018-0418-5

Keywords

Navigation