Abstract
The purpose of this study was to acquire external landmark, undeformed surface, and volume data from a pre-screened individual representing a mid-sized male (height 174.9 cm, weight 78.6 ± 0.77 kg) in the seated and standing postures. The individual matched the 50th percentile value of 15 measures of external anthropometry from previous anthropometric studies with an average deviation of 3%. As part of a related study, a comprehensive full body medical image data set was acquired from the same individual on whom landmark data were collected. Three dimensional bone renderings from this data were used to visually verify the landmark and surface results. A total of 54 landmarks and external surface data were collected using a 7-axis digitizer. A seat buck designed in-house with removable back and seat pan panels enabled collection of undeformed surface contours of the back, buttocks, and posterior thigh. Eight metrics describing the buck positioning are provided. A repeatability study was conducted with three trials to assess intra-observer variability. Total volume and surface area of the seated model were found to be 75.8 × 103 cm3 and 18.6 × 103 cm2 and match the volume and surface area of the standing posture within 1%. Root mean squared error values from the repeatability study were on average 5.9 and 6.6 mm for the seated and standing postures respectively. The peak RMS error as a percentage of the centroid size of the landmark data sets were 3% for both the seated and standing trials. The data were collected as part of a global program on the development of an advanced human body model for blunt injury simulation. In addition, the reported data can be used for many diverse applications of biomechanical research such as ergonomics and morphometrics studies.
Similar content being viewed by others
References
Beeman, S. M., A. R. Kemper, M. L. Madigan, and S. M. Duma. Effects of bracing on human kinematics in low-speed frontal sled tests. Ann. Biomed. Eng. 39:2998–3010, 2011.
Beyer, J. A., S. Rowson, and S. M. Duma. Concussions experienced by major league baseball catchers and umpires: field data and experimental baseball impacts. Ann. Biomed. Eng. 40:150–159, 2012.
Biermann, P., E. Ward, R. Cain, B. Carkhuff, A. Merkle, and J. Roberts. Development of a physical human surrogate torso model for ballistic impact and blast. J. Adv. Mater. 38:3–12, 2006.
Burmaster, D. Lognormal distributions for skin area as a function of body weight. Risk Anal. 18:27, 1998.
CDC. WISQARS (Web-Based Injury Statistics Query and Reporting System). Atlanta, GA: US Department of Health and Human Services, CDC, 2010. http://www.cdc.gov/injury/wisqars. Accessed October 12, 2010.
Cormier, J., S. Manoogian, J. Bisplinghoff, S. Rowson, A. Santago, C. McNally, S. Duma, and J. t. Bolte. The tolerance of the maxilla to blunt impact. J. Biomech. Eng. 133:064501, 2011.
Cormier, J., S. Manoogian, J. Bisplinghoff, S. Rowson, A. Santago, C. McNally, S. Duma, and J. t. Bolte. The tolerance of the frontal bone to blunt impact. J. Biomech. Eng. 133:021004, 2011.
Danelson, K. A., F. S. Gayzik, M. M. Yu, R. S. Martin, S. D. Duma, and J. D. Stitzel. Bilateral carotid artery injury response in side impact using a vessel model integrated with a human body model. Ann. Adv. Automot. Med. 53:271–279, 2009.
Della-Croce, U., A. Cappozzo, and D. Kerrigan. Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles. Med. Biol. Eng. Comput. 37:155–161, 1999.
Dubois, D., and E. F. Dubois. A formula to estimate the approximate surface area if height and weight be known. Arch. Intern. Med. 17:863–871, 1916.
Flannagan, C., M. Manary, L. Schneider, and M. Reed. An improved seating accommodation model with application to different user populations. In: SAE International Conference and Exposition, Feb 23–26, 1998, Detroit, MI. SAE paper number 980651, 1998.
Gayzik, F. S., C. Hamilton, J. Tan, C. McNally, K. D. Klinich, S. M. Duma, and J. D. Stitzel. A Multi-Modality Image Data Collection Protocol for Full Body Finite Element Model Development. SAE Technical Paper 2009-01-2261, 2009. doi:10.4271/2009-01-2261.
Gayzik, F. S., D. Moreno, C. Geer, D. Wuertzer, R. Martin, and J. D. Stitzel. Development of a full body CAD dataset for computational modeling: a multi-modality approach. Ann. Biomed. Eng. 39(10):2568–2583, 2011.
Gayzik, F., M. Yu, K. Danelson, D. Slice, and J. D. Stitzel. Quantification of age-related change of the human rib cage through geometric morphometrics. J. Biomech. 41:1545–1554, 2008.
Gordon, C. C., T. Churchill, C. E. Clauser, B. Bradtmiller, J. T. McConville, I. Tebbetts, and R. A. Walker. Anthropometric Survey of U.S. Army Personnel: Methods and Summary Statistics. 1989, Technical Report: Natick/TR-89/044. Prepared for United States Army Natick Research, Development and Engineering Center, Natick, MA, 1988.
Hallman, J. J., N. Yoganandan, and F. A. Pintar. Prediction of visceral response to multi-directional loading as measured by the chestband. Med. Eng. Phys. 2011. doi:10.1016/j.medengphy.2011.10.006.
Haycock, G. B., G. J. Schwartz, and D. H. Wisotsky. Geometric method for measuring body surface area: a height–weight formula validated in infants, children, and adults. J. Pediatr. 93:62–66, 1978.
Hodgdon, J. A., M. Brandsma, H. Daanen, and L. Hervig. Prediction of Body Surface Area Based on 3-Dimensional Laser Scans. Technical Report, U.S. Army Medical Research and Materiel Command. Fort Detrick, MD, 2005.
Iwamoto, M., Y. Kisanuki, I. Wantanabe, K. Furusu, K. Miki, and J. Hasegawa. Development of a finite element model of the Total Human Model for Safety (THUMS) and application to injury reconstruction. In: International Research Council on the Biomechanics of Injury (IRCOBI), Munich, Germany, 2002.
Kemper, A. R., E. A. Kennedy, C. McNally, S. J. Manoogian, J. D. Stitzel, and S. M. Duma. Reducing chest injuries in automobile collisions: rib fracture timing and implications for thoracic injury criteria. Ann. Biomed. Eng. 39:2141–2151, 2011.
Kemper, A. R., A. C. Santago, J. D. Stitzel, J. L. Sparks, and S. M. Duma. Biomechanical response of human spleen in tensile loading. J. Biomech. 45:348–355, 2012.
Kemper, A. R., J. D. Stitzel, C. McNally, H. C. Gabler, and S. M. Duma. Biomechanical response of the human clavicle: the effects of loading direction on bending properties. J. Appl. Biomech. 25:165–174, 2009.
Kimpara, H., J. B. Lee, K. H. Yang, A. I. King, M. Iwamoto, I. Watanabe, and K. Miki. Development of a three-dimensional finite element chest model for the 5(th) percentile female. Stapp Car Crash J. 49:251–269, 2005.
Manary, M., C. Flannagan, M. Reed, and L. W. Schneider. Development of an improved driver eye position model. In: SAE World Congress and Exposition, Detroit, MI. SAE, 1998.
Manary, M., M. Reed, C. Flannagan, and L. Shchneider. ATD positioning based on driver posture and position. Stapp Car Crash J. 42:337, 1998.
Manary, M., L. Schneider, C. Flannagan, and B. Eby. Evaluation of the SAE J826 3-D manikin measures of driver positioning and posture. In: SAE International Congress and Exposition, Feb 24–26, 1994, Detroit, MI. SAE paper number 1994-03-01, 1994.
Manoogian, S. J., J. A. Bisplinghoff, C. McNally, A. R. Kemper, A. C. Santago, and S. M. Duma. Dynamic tensile properties of human placenta. J. Biomech. 41:3436–3440, 2008.
Manoogian, S. J., J. A. Bisplinghoff, C. McNally, A. R. Kemper, A. C. Santago, and S. M. Duma. Effect of strain rate on the tensile material properties of human placenta. J. Biomech. Eng. 131:091008, 2009.
McConville, J., T. Churchill, I. Kaleps, C. Clauser, and J. Cuzzi. Anthropometry Relationships of Body and Body Segment Moments of Inertia. Air Force Aerospace Medical Research Laboratory, Wright-Patterson AFB, OH. AFAMRL-TR-80-119, 1980.
Moorcroft, D. M., J. D. Stitzel, G. G. Duma, and S. M. Duma. Computational model of the pregnant occupant: predicting the risk of injury in automobile crashes. Am. J. Obstet. Gynecol. 189:540–544, 2003.
Mosteller, R. Simplified calculation of body-surface area. N. Engl. J. Med. 317(17):1098, 1987.
Naumann, R. B., A. M. Dellinger, E. Zaloshnja, B. A. Lawrence, and T. R. Miller. Incidence and total lifetime costs of motor vehicle-related fatal and nonfatal injury by road user type, United States, 2005. Traffic Inj. Prev. 11(4):353–360, 2010.
Ogden, C., C. Fryar, M. Carroll, and K. Flegal. Mean body weight, height, and body mass index, United States 1960–2002. In: Advance Data from Vital and Health Statistics; No. 347. Hyattsville, MD: National Center for Health Statistics, 2004.
Reed, M. P., M. A. Manary, and L. W. Schneider. Methods for measuring and representing automobile occupant posture. In: SAE International Congress and Exposition, March 1–4, 1999, Detroit, MI. SAE paper number 1999-01-0959, 1999.
Reed, M., R. Roe, M. Manary, C. Flannagan, and L. Schneider. New concepts in vehicle interior design using ASPECT. In: SAE International Congress and Exposition, March 1–4, 1999, Detroit, MI. SAE paper number 1999-01-0967, 1999.
Robbins, D. Anthropometric specifications for mid-sized male dummy. United States Department of Transportation, National Highway Traffic Safety Administration, DOT/HS 806 715, Vol 2, 1983.
Robin, S. Human model for safety—a joint effort towards the development of redefined human-like car-occupant models. In: 17th International Technical Conference for the Enhanced Safety of Vehicles, June 15–19, 2001, Amsterdam, Netherlands, Paper Number 01-297, 2001.
Rowson, S., and S. M. Duma. Development of the STAR evaluation system for football helmets: integrating player head impact exposure and risk of concussion. Ann. Biomed. Eng. 39:2130–2140, 2011.
Rowson, S., C. McNally, and S. M. Duma. Can footwear affect achilles tendon loading? Clin. J. Sport Med. 20:344–349, 2010.
Rowson, S., D. E. McNeely, P. G. Brolinson, and S. M. Duma. Biomechanical analysis of football neck collars. Clin. J. Sport Med. 18:316–321, 2008.
Ruan, J. s., T. Khalil, and A. I. King. Human head dynamic response to side impact by finite element modeling. J. Biomech. Eng. 113:276, 1991.
Schneider, L., D. Robbins, M. Pflug, and R. Snyder. Development of Anthropometrically Based Design Specifications for an Advanced Adult Anthropometric Dummy Family. United States Department of Transportation, National Highway Traffic Safety Administration, DOT/HS 806 715, Vol 1, 1983.
Shigeta, K., Y. Kitagawa, and T. Yasuki. Development of next generation human FE model capable of organ injury prediction. In: 21st International Technical Conference on the Enhanced Safety of Vehicles, June 15–19, 2009, Stuttgart, Germany. Paper number 09-0111, 2009.
Society of Automotive Engineers. Sign Convention for Vehicle Crash Testing. SAE J1733, Report of the Safety Test Instrumentation Standards Committee, 2007-11-02, SAE International, 2007.
Tikuisis, P., P. Meunier, and C. E. Jubenville. Human body surface area: measurement and prediction using three dimensional body scans. Eur. J. Appl. Physiol. 85:264–271, 2001.
Valentin, J. Basic Anatomical and Physiological Data for Use in Radiological Protection: Reference Values: The International Commission on Radiation Protection, Publication 89. Oxford: Pergamon Press, 2002.
Weaver, A. A., E. A. Kennedy, S. M. Duma, and J. D. Stitzel. Evaluation of different projectiles in matched experimental eye impact simulations. J. Biomech. Eng. 133:031002, 2011.
Weaver, A. A., K. L. Loftis, S. M. Duma, and J. D. Stitzel. Biomechanical modeling of eye trauma for different orbit anthropometries. J. Biomech. 44:1296–1303, 2011.
Woodhull, A., K. Maltrud, and B. Mello. Alignment of the human body in standing. Eur. J. Appl. Physiol. Occup. Physiol. 54:109–115, 1985.
Yang, K. H., J. Hu, N. A. White, A. I. King, C. C. Chou, and P. Prasad. Development of numerical models for injury biomechanics research: a review of 50 years of publications in the Stapp Car Crash conference. Stapp Car Crash J. 50:429–490, 2006.
Acknowledgments
Funding for this work was provided by the Global Human Body Models Consortium, LLC (GHBMC) through grant WFU: FBM-001. CAD development work was supported by Zygote Media Group, Inc. (American Fork, UT). Thanks to SBES student Dustin Crouch for assistance with data collection. Thanks to Dr. Scott Wuertzer of Wake Forest University School of Medicine, Division of Radiology for reviewing medical images related to this study.
Conflict of interest
None.
Author information
Authors and Affiliations
Corresponding author
Additional information
Associate Editor Claude R. LeBrun oversaw the review of this article.
Appendix
Appendix
Rights and permissions
About this article
Cite this article
Gayzik, F.S., Moreno, D.P., Danelson, K.A. et al. External Landmark, Body Surface, and Volume Data of a Mid-Sized Male in Seated and Standing Postures. Ann Biomed Eng 40, 2019–2032 (2012). https://doi.org/10.1007/s10439-012-0546-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10439-012-0546-z