The Effect of Varying Magnitudes of Whole-Body Vibration on Several Skeletal Sites in Mice

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

It has been reported that whole-body vibration (WBV) is anabolic to trabecular bone in animal models and humans. It is likely that this anabolic response does not occur uniformly throughout the entire body. Two factors that may affect the observed anabolic response are vibration magnitude and skeletal site of interest. In this study, mice were loaded with WBV of varying magnitudes. After five weeks of loading, bone marrow was flushed from tibias in order to quantify osteoprogenitor cells. Staining with alizarin red (an indicator of mineralization) showed a significant decrease in percent stained area in the 0.3 g loaded group compared to the control group and the 1.0 g group. MicroCT analysis was performed at five skeletal sites: the proximal tibial metaphysis, femoral condyles, distal femoral metaphysis, proximal femur, and L5 vertebral body. Increasing magnitudes of WBV were associated with a non-dose-dependent increase in trabecular bone volume (BV/TV) at the proximal tibial metaphysis, although other sites were unresponsive. There were statistically significant increases in BV/TV in the 0.1 g group (32% increase) and 1.0 g group (43% increase) compared to control (p < 0.05). The 0.1 g and 1.0 g groups also had higher BV/TV than the 0.3 g loaded group. If this non-dose-dependent phenomenon is verified by future studies, it suggests that a range of magnitudes should be examined for each application of WBV.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

FIGURE 1.
FIGURE 2.
FIGURE 3.
FIGURE 4.
FIGURE 5.

Similar content being viewed by others

REFERENCES

  1. Flieger, J., T. Karachalios, L. Khaldi, P. Raptou, and G. Lyritis. Mechanical stimulation in the form of vibration prevents postmenopausal bone loss in ovariectomized rats. Calcif. Tissue Int. 63:510–514, 1998.

    Article  PubMed  CAS  Google Scholar 

  2. Fritton, J. C., C. T. Rubin, Y. X. Qin, and K. J. McLeod. Whole-body vibration in the skeleton: development of a resonance-based testing device. Ann. Biomed. Eng. 25:831–839, 1997.

    Article  PubMed  CAS  Google Scholar 

  3. Funakoshi, M., K. Taoda, H. Tsujimura, and K. Nishiyama. Measurement of whole-body vibration in taxi drivers. J. Occup. Health 46:119–124, 2003.

    Article  Google Scholar 

  4. Grano, M., G. Mori, V. Minielli, O. Barou, S. Colucci, G. Giannelli, C. Alexandre, A. Z. Zallone, and L. Vico. Rat hindlimb unloading by tail suspension reduces osteoblast differentiation, induces IL-6 secretion, and increases bone resorption in ex vivo cultures. Calcif. Tissue Int. 70:176–185, 2002.

    Article  PubMed  CAS  Google Scholar 

  5. Hildebrand, T., and P. Rüegsegger. A new method for the model-independent assessment of thickness in three-dimensional images. J. Microsc. 185:67–75, 1997.

    Article  Google Scholar 

  6. Judex, S., S. Boyd, Y. X. Qin, S. Turner, K. Ye, R. Muller, and C. Rubin. Adaptations of trabecular bone to low magnitude vibrations result in more uniform stress and strain under load. Ann. Biomed. Eng. 31:12–20, 2003.

    Article  PubMed  Google Scholar 

  7. Judex, S., L. R. Donahue, and C. Rubin. Genetic predisposition to low bone mass is paralleled by an enhanced sensitivity to signals anabolic to the skeleton. FASEB J., 16:1280–1282, 2002.

    PubMed  CAS  Google Scholar 

  8. Kostenuik, P. J., B. P. Halloran, E. R. Morey-Holton, and D. D. Bikle. Skeletal unloading inhibits the in vitro proliferation and differentiation of rat osteoprogenitor cells. Am. J. Physiol. 273:E1133–E1139, 1997.

    PubMed  CAS  Google Scholar 

  9. Lei, X., D. Han, R. Garman, C. Rubin, and S. Judex. Adaptation of bone to low magnitude vibrations is dependent on the applied frequency but not on the induced strain magnitude. 51st Annual Meeting of the Orthopaedic Research Society. Paper No: 0214, 2005.

  10. Matsumoto, Y., and M. J. Griffin. Dynamic response of the standing human body exposed to vertical vibration: influence of posture and vibration magnitude. J. Sound Vib. 212:85–107, 1998.

    Article  Google Scholar 

  11. Matsumoto, Y., and M. J. Griffin. Non-linear characteristics in the dynamic responses of seated subjects exposed to vertical whole-body vibration. J. Biomech. Eng. 124:527–532, 2002.

    Article  PubMed  Google Scholar 

  12. Melton, L. J., 3rd. How many women have osteoporosis now? J. Bone Miner. Res. 10:175–177, 1995.

    PubMed  Google Scholar 

  13. National Osteoporosis Foundation. Disease statistics “fast facts”. Retrieved May 11, 2005, from National Osteoporosis Foundation Web site: http://www.nof.org/osteoporosis/ diseasefacts.htm

  14. Oxlund, B. S., G. Ortoft, T. T. Andreassen, and H. Oxlund. Low-intensity, high-frequency vibration appears to prevent the decrease in strength of the femur and tibia associated with ovariectomy of adult rats. Bone 32:69–77, 2003.

    Article  PubMed  CAS  Google Scholar 

  15. Parry, L. K., V. J. Burton, S. Gheduzzi, J. Beresford, M. J. Perry, T. M. Skerry, and V. F. Humphrey. Ultrasound mimics the effect of mechanical loading in vivo on rat ulnae and bone marrow cells. ASBMR Annual Meeting. Presentation Number SU154, 2003.

  16. Rubin, C., M. Pope, J. C. Fritton, M. Magnusson, T. Hansson, and K. McLeod. Transmissibility of 15-hertz to 35-hertz vibrations to the human hip and lumbar spine: determining the physiologic feasibility of delivering low-level anabolic mechanical stimuli to skeletal regions at greatest risk of fracture because of osteoporosis. Spine 28:2621–2627, 2003.

    Article  PubMed  Google Scholar 

  17. Rubin, C., R. Recker, D. Cullen, J. Ryaby, J. McCabe, and K. McLeod. Prevention of postmenopausal bone loss by a low-magnitude, high-frequency mechanical stimuli: a clinical trial assessing compliance, efficacy, and safety. J. Bone Miner. Res. 19:343–351, 2004.

    Article  PubMed  Google Scholar 

  18. Rubin, C. T., D. W. Sommerfeldt, S. Judex, and Y. Qin. Inhibition of osteopenia by low magnitude, high-frequency mechanical stimuli. Drug Discov. Today 6:848–858, 2001.

    Article  PubMed  Google Scholar 

  19. Rubin, C., A. S. Turner, S. Bain, C. Mallinckrodt, and K. McLeod. Anabolism. Low mechanical signals strengthen long bones. Nature 412:603–604, 2001.

    Article  PubMed  CAS  Google Scholar 

  20. Rubin, C., A. S. Turner, R. Muller, E. Mittra, K. McLeod, W. Lin, and Y. X. Qin. Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention. J. Bone Miner. Res. 17:349–357, 2002.

    Article  PubMed  Google Scholar 

  21. Rubin, C., A. S. Turner, C. Mallinckrodt, C. Jerome, K. McLeod, S. Bain. Mechanical strain, induced noninvasively in the high-frequency domain, is anabolic to cancellous bone, but not cortical bone. Bone 30:445–452, 2002.

    Article  PubMed  CAS  Google Scholar 

  22. Rubin, C., G. Xu, and S. Judex. The anabolic activity of bone tissue, suppressed by disuse, is normalized by brief exposure to extremely low-magnitude mechanical stimuli. FASEB J. 15: 2225–2229, 2001.

    Article  PubMed  CAS  Google Scholar 

  23. Silva, M. J., M. D. Brodt, M. Ko, and Y. Abu-Amer. Impaired marrow osteogenesis is associated with reduced endocortical bone formation but does not impair periosteal bone formation in long bones of SAMP6 mice. J. Bone Miner. Res. 20:419–427, 2005.

    Google Scholar 

  24. Tanaka, S. M., I. M. Alam, and C. H. Turner. Stochastic resonance in osteogenic response to mechanical loading. FASEB J. 17:313–314, 2003.

    PubMed  CAS  Google Scholar 

  25. Torvinen, S., P. Kannus, H. Sievanen, T. A. Jarvinen, M. Pasanen, S. Kontulainen, A. Nenonen, T. L. Jarvinen, T. Paakkala, M. Jarvinen, and I. Vuori. Effect of 8-month vertical whole body vibration on bone, muscle performance, and body balance: a randomized controlled study. J. Bone Miner. Res. 18:876–884, 2003.

    Article  PubMed  Google Scholar 

  26. Tsuchikane, A., Y. Nakatsuchi, and A. Nomura. The influence of joints and soft tissue on the natural frequency of the human tibia using the impulse response method. Proc. Inst. Mech. Eng. [H] 209:149–155, 1995.

    CAS  Google Scholar 

  27. Turner, C. H., M. R. Forwood, J. Y. Rho, and T. Yoshikawa. Mechanical loading thresholds for lamellar and woven bone formation. J. Bone Miner. Res. 9: 87–97, 1994.

    PubMed  CAS  Google Scholar 

  28. Van der Perre, G., R. Van Audekercke, M. Martens, and J. C. Mulier. Identification of in-vivo vibration modes of human tibiae by modal analysis. J. Biomech. Eng. 105:244–248, 1983.

    Article  PubMed  CAS  Google Scholar 

  29. Verschueren, S. M., M. Roelants, C. Delecluse, S. Swinnen, D. Vanderschueren, and S. Boonen. Effect of 6-month whole body vibration training on hip density, muscle strength, and postural control in postmenopausal women: a randomized controlled pilot study. J. Bone Miner. Res. 19:352–359, 2004.

    Article  PubMed  Google Scholar 

  30. Ward, K., C. Alsop, J. Caulton, C. Rubin, J. Adams, and Z. Mughal. Low magnitude mechanical loading is osteogenic in children with disabling conditions. J. Bone Miner. Res. 19:360–369, 2004.

    Article  PubMed  Google Scholar 

  31. Zhang, R., S. C. Supowit, G. L. Klein, Z. Lu, M. D. Christensen, R. Lozano, and D. J. Simmons. Rat tail suspension reduces messenger RNA level for growth factors and osteopontin and decreases the osteoblastic differentiation of bone marrow stromal cells. J. Bone Miner. Res. 10:415–423, 1995.

    Article  PubMed  CAS  Google Scholar 

Download references

ACKNOWLEDGMENTS

This study was funded by a grant from the U.S. National Institutes of Health, National Institute of Arthritis, Musculoskeletal, and Skin Diseases (AR 47867). The authors thank Mike Ko for assistance with cell culture and acknowledge Michael Dahl, Kiran Pandey, and Michael Peters for design of the loading device.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Blaine A. Christiansen.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Christiansen, B.A., Silva, M.J. The Effect of Varying Magnitudes of Whole-Body Vibration on Several Skeletal Sites in Mice. Ann Biomed Eng 34, 1149–1156 (2006). https://doi.org/10.1007/s10439-006-9133-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10439-006-9133-5