Abstract
Purpose
To develop a novel method for measuring tear break-up time (BUT) by continuously measuring higher order wavefront aberrations using a Hartmann-Shack (H-S) aberrometer.
Methods
Wavefront aberrations up to the sixth order for a 4-mm pupil were measured in six eyes of six normal subjects using an H-S aberrometer. The aberrometry was performed once every second for up to 50 s under topical anesthesia. The sequence of the points was divided into two stages, and the BUT was defined as the wavefront border of the stages (WFBUT). The WFBUT was compared with the BUT by the conventional fluorescein method (FLBUT) or by the disruption of placid-ring images (PLBUT).
Results
In three eyes, the WFBUT (average, 10.9 ± 1.1 s) was shorter than the PLBUT (average, 17.5 ± 2.5 s), while in the other three eyes the WFBUT (average, 21.5 ± 2.2 s) was longer than PLBUT (average, 8.1 ± 2.2 s). The FLBUT was shorter than WFBUT or PLBUT in most cases.
Conclusions
The tear break-up time measured by H-S aberrometer may be used as a practical measure of tear break-up. Jpn J Ophthalmol 2006;50:85–89 © Japanese Ophthalmological Society 2006
Similar content being viewed by others
References
DW Lamberts (1994) Physiology of the tear film RA Thoft (Eds) The cornea EditionNumber3rd ed. Little, Brown & Company Boston
NL Himebaugh AR Wright A Bradley CG Begley LN Thibos (2003) ArticleTitleUse of retroillumination to visualize optical aberrations caused by tear film break-up Optom Vis Sci 80 69–78 Occurrence Handle12553546
J Nemeth B Erdelyi B Csakany et al. (2002) ArticleTitleHigh-speed videotopographic measurement of tear film build-up time Invest Ophthalmol Vis Sci 43 1783–1790 Occurrence Handle12036979
T Goto X Zheng SD Klyce et al. (2003) ArticleTitleA new method for tear film stability analysis using videokeratography Am J Ophthalmol 135 607–612 Occurrence Handle12719066
LC Thai A Tomlinson WH Ridder (2002) ArticleTitleContact lens drying and visual performance: the vision cycle with contact lenses Optom Vis Sci 79 381–388 Occurrence Handle12086305
N Yokoi Y Takehisa S Kinoshita (1996) ArticleTitleCorrelation of tear lipid layer interference patterns with the diagnosis and severity of dry eye Am J Ophthalmol 122 818–824 Occurrence Handle1:STN:280:ByiC3MritlE%3D Occurrence Handle8956636
LN Thibos X Hong (1999) ArticleTitleClinical applications of the Shack-Hartmann aberrometer Optom Vis Sci 76 817–825 Occurrence Handle1:STN:280:DC%2BD3c%2FnslKnuw%3D%3D Occurrence Handle10612402
S Koh N Maeda T Kuroda et al. (2002) ArticleTitleEffect of tear film break-up on higher-order aberrations measured with wavefront sensor Am J Ophthalmol 134 115–117 Occurrence Handle10.1016/S0002-9394(02)01430-7 Occurrence Handle12095817
R Montes-Mico JL Alio G Munoz WN Charman (2004) ArticleTitleTemporal changes in optical quality of air–tear film interface at anterior cornea after blink Invest Ophthalmol Vis Sci 45 1752–1757 Occurrence Handle10.1167/iovs.03-0839 Occurrence Handle15161836
S Ninomiya T Fujikado T Kuroda et al. (2002) ArticleTitleChanges of ocular aberration with accommodation Am J Ophthalmol 134 924–926 Occurrence Handle10.1016/S0002-9394(02)01856-1 Occurrence Handle12470772
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Mihashi, T., Hirohara, Y., Koh, S. et al. Tear Film Break-up Time Evaluated by Real-Time Hartmann-Shack Wavefront Sensing. Jpn J Ophthalmol 50, 85–89 (2006). https://doi.org/10.1007/s10384-005-0289-6
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s10384-005-0289-6