Reproducibility of methods for assessing baroreflex sensitivity and temporal QT variability in end-stage renal disease and healthy subjects

  • RESEARCH ARTICLE
  • Published:
Clinical Autonomic Research Aims and scope Submit manuscript

Abstract

Spontaneous baroreflex sensitivity (BRS), the reflex heart rate modulation in response to blood pressure changes (predominantly an index of cardiac vagal activity) and temporal QT variability (an index of myocardial repolarization) have been demonstrated to convey important prognostic information. The information about reproducibility of BRS and temporal QT variability is limited and there is lack of information regarding patients with cardiovascular diseases. We investigated reproducibility of spontaneous BRS using the sequence technique and temporal QT variability index (QTVI) in terms of intra-, interexaminer and within-subject variability in end-stage renal disease patients (ESRD, n=17, age 55±14 years) and healthy subjects (HS, n=29, age 32±12 years, P<0.01). ECG and blood pressure (Portapres) were recorded on two separate days and BRS and QTVI were evaluated by two independent examiners. The mean heart rate was similar in ESRD patients in comparison to healthy controls, whereas the mean arterial pressure was 13 % higher in ESRD patients (P<0.01). Spontaneous BRS was 62% lower (P<0.01) and QTVI was 41% higher in ESRD patients (P<0.01) compared to healthy subjects, respectively. Coefficient of variation (CV) of within-subject reproducibility of BRS and QTVI measurements was moderate (BRS: 33 % for ESRD, 27% for HS; QTVI: 40% for ESRD, 18% for HS). The 95% limit of within-subject reproducibility of BRS measurements was 3.8ms/mm Hg for ESRD patients and 8.1ms/mm Hg for healthy subjects; whereas the 95% limit of reproducibility of within-subject reproducibility of QTVI measurements was 0.73 for ESRD patients and 0.55 for healthy subjects. Concordance correlation coefficients of within-subject variability of BRS and QTVI were between 0.74 and 0.83 in both groups. CV of intra- and inter-examiner reproducibility of BRS and QTVI measurements in both groups ranged between 1 and 11%. In conclusion, the intra- and inter-examiner reproducibility/agreement of BRS and QTVI were high, whereas the within-subject reproducibility of these two methods was moderate, in both ESRD patients and healthy subjects. Thus, small differences in BRS and QTVI in longitudinal/interventional studies should be interpreted with caution.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Atiga WL, Calkins H, Lawrence JH, Tomaselli GF, Smith JM, Berger RD (1998) Beat-to-beat repolarization lability identifies patients at risk for sudden cardiac death. J Cardiovasc Electrophysiol 9:899–908

    CAS  PubMed  Google Scholar 

  2. Berger RD, Kasper EK, Baughman KL, Marban E, Calkins H, Tomaselli GF (1997) Beat-to-beat QT interval variability: novel evidence for repolarization lability in ischemic and nonischemic dilated cardiomyopathy. Circulation 96:1557–1565

    Google Scholar 

  3. Bertinieri G, di Rienzo M, Cavallazzi A, Ferrari AU, Pedotti A, Mancia G (1985) A new approach to analysis of the arterial baroreflex. J Hypertens (Suppl 3):S79–81

  4. Bertinieri G, Di Rienzo M, Cavallazzi A, Ferrari AU, Pedotti A, Mancia G (1988) Evaluation of baroreceptor reflex by blood pressure monitoring in unanesthetized cats [published erratum appears in Am J Physiol 1988 Sep, 255(3 Pt 2): following H405]. Am J Physiol 254:H377–H383

    Google Scholar 

  5. Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310

    CAS  PubMed  Google Scholar 

  6. Davies LC, Francis D, Jurak P, Kara T, Piepoli M, Coats AJ (1999) Reproducibility of methods for assessing baroreflex sensitivity in normal controls and in patients with chronic heart failure. Clin Sci (Colch) 97:515–522

    Google Scholar 

  7. Dawson SL, Robinson TG, Youde JH, James MA, Martin A, Weston P, Panerai R, Potter JF (1997) The reproducibility of cardiac baroreceptor activity assessed noninvasively by spectral sequence techniques. Clin Auton Res 7:279–284

    Google Scholar 

  8. Foley RN, Parfrey PS, Sarnak MJ (1998) Epidemiology of cardiovascular disease in chronic renal disease. J Am Soc Nephrol 9:S16–S23

    Google Scholar 

  9. Gao SA, Ambring A, Lambert G, Karlsson AK (2002) Autonomic control of the heart and renal vascular bed during autonomic dysreflexia in high spinal cord injury. Clin Auton Res 12:457–464

    Google Scholar 

  10. Herpin D, Ragot S (1997) Mid- and long-term reproducibility of noninvasive measurements of spontaneous arterial baroreflex sensitivity in healthy volunteers. Am J Hypertens 10:790–797

    Google Scholar 

  11. Iellamo F, Legramante JM, Raimondi G, Castrucci F, Massaro M, Peruzzi G (1996) Evaluation of reproducibility of spontaneous baroreflex sensitivity at rest and during laboratory tests. J Hypertens 14:1099–1104

    Google Scholar 

  12. Kardos A, Watterich G, de Menezes R, Csanady M, Casadei B, Rudas L (2001) Determinants of spontaneous baroreflex sensitivity in a healthy working population. Hypertension 37:911–916

    Google Scholar 

  13. La Rovere MT, Bigger JT Jr, Marcus FI, Mortara A, Schwartz PJ (1998) Baroreflex sensitivity and heart-rate variability in prediction of total cardiac mortality after myocardial infarction. ATRAMI (Autonomic Tone and Reflexes After Myocardial Infarction) Investigators. Lancet 351:478–484

    Article  Google Scholar 

  14. Lin LI (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268

    CAS  PubMed  Google Scholar 

  15. Lipman RD, Salisbury JK, Taylor JA (2003) Spontaneous indices are inconsistent with arterial baroreflex gain. Hypertension 42:481–487

    Google Scholar 

  16. Parati G, Pomidossi G, Ramirez A, Gavazzi C, Bertinieri G, Mancia G (1983) Reproducibility of laboratory tests evaluating neural cardiovascular regulation in man. J Hypertens (Suppl 1):88–90

  17. Parati G, Di Rienzo M, Bertinieri G, Pomidossi G, Casadei R, Groppelli A, Pedotti A, Zanchetti A, Mancia G (1988) Evaluation of the baroreceptor-heart rate reflex by 24-hour intra-arterial blood pressure monitoring in humans. Hypertension 12:214–222

    Google Scholar 

  18. Parlow J, Viale JP, Annat G, Hughson R, Quintin L (1995) Spontaneous cardiac baroreflex in humans. Comparison with drug-induced responses. Hypertension 25:1058–1068

    Google Scholar 

  19. Piccirillo G, Cacciafesta M, Lionetti M, Nocco M, Di Giuseppe V, Moise A, Naso C, Marigliano V (2001) Influence of age, the autonomic nervous system and anxiety on QT-interval variability. Clin Sci 101:429–438

    Google Scholar 

  20. Quan H, Shih WJ (1996) Assessing reproducibility by the within-subject coefficient of variation with random effects models. Biometrics 52:1195–1203

    Google Scholar 

  21. Robinson TG, Dawson SL, Eames PJ, Panerai RB, Potter JF (2003) Cardiac baroreceptor sensitivity predicts long-term outcome after acute ischemic stroke. Stroke 34:705–712

    Google Scholar 

  22. Tank J, Baevski RM, Fender A, Baevski AR, Graves KF, Ploewka K, Weck M (2000) Reference values of indices of spontaneous baroreceptor reflex sensitivity. Am J Hypertens 13:268–275

    Google Scholar 

  23. Watkins LL, Grossman P, Sherwood A (1996) Noninvasive assessment of baroreflex control in borderline hypertension. Comparison with the phenylephrine method. Hypertension 28:238–243

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sinsia A. Gao MD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gao, S.A., Johansson, M., Hammarén, A. et al. Reproducibility of methods for assessing baroreflex sensitivity and temporal QT variability in end-stage renal disease and healthy subjects. Clin Auton Res 15, 21– 28 (2005). https://doi.org/10.1007/s10286-005-0224-4

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10286-005-0224-4

Key words

Navigation