Abstract
Brain perfusion diseases such as acute ischemic stroke are detectable through computed tomography (CT)-/magnetic resonance imaging (MRI)-based methods. An alternative approach makes use of ultrasound imaging. In this low-cost bedside method, noise and artifacts degrade the imaging process. Especially stripe artifacts show a similar signal behavior compared to acute stroke or brain perfusion diseases. This document describes how stripe artifacts can be detected and eliminated in ultrasound images obtained through harmonic imaging (HI). On the basis of this new method, both proper identification of areas with critically reduced brain tissue perfusion and classification between brain perfusion defects and ultrasound stripe artifacts are made possible.
Similar content being viewed by others
References
Burns, PN: Harmonic imaging with ultrasound contrast agents. Clin Radiol 51:50, 1996
De Jong N, Frinking PJ, Bouakaz A: Detection procedures of ultrasound contrast agents. Ultrasonics 38:87–92, 2000
Harrer J: Second harmonic imaging of the human brain. Stroke 33(1):1530–1536, 2002
Liu Y: Cerebral hemodynamics in human acute ischemic stroke: a study with diffusion- and perfusion-weighted magnetic resonance imaging and SPECT. J Cereb Blood Flow Metab 20: 910–920, 2000
Meves S, Wilkening W, Thies T, Eyding J, Ermert HTP: Comparison between echo contrast agent-specific imaging modes and perfusion-weighted magnetic resonance imaging for assessment of brain perfusion. Stroke 33(1):2433–2437, 2002
Eyding J, Postert T, Wilkening W: Brain perfusion and ultrasonic imaging techniques. Eur J Ultrasound 16:91–104, 2002
Eyding J, Wilkening W, Reckhard M: Contrast burst depletion imaging—a new imaging procedure and analysis method for semiquantitative ultrasonic perfusion imaging. Stroke 34(1):77–83, 2002
Eyding J, Krogias C, Wilkening W: Parameters of cerebral perfusion in phase-inversion harmonic imaging (PIHI) ultrasound examinations. Ultrasound Med Biol 29(10):1379–1385, 2003
Postert T, Muhs A, Meves SJF: Transient response harmonic imaging: an ultrasound technique related to brain perfusion. Stroke 29:1901–1907, 1998
Postert T, Hoppe P, Federlein JSH, Ermert H, Przuntek H, Büttner T, Wilkening W: Contrast agent specific imaging modes for the ultrasonic assessment of parenchymal cerebral echo contrast enhancement. Metabolism 20:1709–1716, 2000
Postert T, Hoppe P, Federlein J, Przuntek H, Büttner T, Helbeck S, Ermert H: Ultrasonic assessment of brain perfusion. Stroke 31:1460–1462, 2000
Seidel G, Kaps M, Greis C: Second harmonic imaging of a new ultrasound contrast agent (BY963): visualization of small cerebral arteries and analysis of regional cerebral blood flow. J Neuroimaging 7:230, 1997
Seidel G, Algermissen C, Kaps M: Harmonic imaging des Hirnparenchyms nach BR14 Bolusinjektion. Ultraschall in der Medizin 19:13, 1998
Wiesmann MGS: Ultrasound perfusion imaging of the human brain. Stroke 31:2421–2425, 2000
Nanda NCRS: Advances in Echo Imaging Using Contrast Enhancement, 1 edn. Norwell, MA: Kluwer, 1993
Noble JA: Ultrasound image segmentation: a survey. IEEE Trans Med Imag 25(8):987–1010, 2006
Seidel G, Algermissen C, Christoph A, Claassen L, Vidal-Langwasser MTK: Harmonic imaging of the human brain: visualization of brain perfusion with ultrasound. Stroke 31:151–154, 2000
Vollrath A, Kier C, Meyer-Wiethe K, Seidel G, Aach T: Detecting stripe artifacts in ultrasound parametric images. In: Biomedizinische Technik, volume 50. Berlin: Fachverlag Schiele und Schön, 2005, pp 1235–1236
Feigenbaum H: Echocardiography, 5th edn. Philadelphia: Lea and Febiger, 1994
Grolimund P: Transmission of ultrasound through the temporal bone. In Aaslid R Ed. Transcranial Doppler Sonography. Berlin Heidelberg New York: Springer, 1986
Wei K, Jayaweera AR Firoozan S, Linka A, Skyba DMSK: Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion, volume 97. Berlin Heidelberg New York: Springer, 1998, pp 473–483
Seidel G, Algermissen C, Christoph A, Katzer T, Kaps M: Visualization of brain perfusion using harmonic grey scale and power doppler technology: an animal pilot study. Stroke 31:1728–1734, 2000
Metzler V, Seidel G, Meyer-Wiethe K, Wiesmann M, Aach T: Perfusion harmonic imaging of the human brain. In: Ultrasonic Imaging and Signal Processing, volume 5035. Proceedings of SPIE, San Diego, CA, 2003, pp 337–348
Martina AD, Seidel G, Meyer-Wiethe KEA: Ultrasound contrast agents for brain perfusion imaging and ischemic stroke therapy—instrumentation in practice. J Neuroimaging 33(1):1530–1537, 2005
Seidel GKMW: Harmonic imaging—Eine neue Methode zur sonographischen Darstellung der Hirnperfusion. Nervenarzt 72(1):600–610, 2001
Kier C, Toth D, Schindler LA, Meyer-Wiethe K, Cangür H, Seidel G, Aach T: Cerebral perfusion imaging with bolus harmonic imaging. In Walker WF, Emelianov SY Eds. Ultrasonic Imaging and Signal Processing, volume 5750. San Proceedings of SPIE, San Diego, CA, 2005, pp 437–446
Wilkening W, Postert T, Federlein J, Kono Y, Mattrey R, Ermert H: Ultrasonic assessment of perfusion conditions in the brain and in the liver. In: IEEE Ultrasonics Symposium, San Juan, Puerto Rico, 2000, pp 1545–1548
Teague MR: Image analysis via the general theory of moments. Optical Society of America, 1979, pp 920–930
Reiss TH: Recognizing planar objects, using invariant image features. In: Lecure Notes in Computer Science, volume 676. Berlin Heidelberg New York: Springer, 1993, p 30
Jähne, B.: Digital Image Processing, 6th edn. Berlin Heidelberg New York: Springer, 2005
Jain AK: Fundamentals of Digital Image Processing, 1st edn. Prentice-Hall, New Jersey, 1989
Acknowledgment
The authors would like to thank Toni W. Vomweg and Sarah M. Hilbert, CADMEI GmbH, Germany, for their assistance and valuable input.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Maciak, A., Kier, C., Seidel, G. et al. Detecting Stripe Artifacts in Ultrasound Images. J Digit Imaging 22, 548–557 (2009). https://doi.org/10.1007/s10278-007-9049-0
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10278-007-9049-0