This article documents the results of the first in a series of experiments designed to evaluate the suitability of a novel, high resolution, color, digital, liquid crystal display (LCD) panel for diagnostic quality, gray scale image display. The goal of this experiment was to measure the performance of the display, especially with respect to luminance. The panel evaluated was the IBM T221 22.2” backlit active matrix liquid crystal display (AMLCD) with native resolution of 3840 × 2400 pixels. Taking advantage of the color capabilities of the workstation, we were able to create a 256-entry grayscale calibration look-up table derived from a palette of 1786 nearly gray luminance values. We also constructed a 256-entry grayscale calibration look-up table derived from a palette of 256 true gray values for which the red, green, and blue values were equal. These calibrations will now be used in our evaluation of human contrast-detail perception on this LCD panel.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6

Similar content being viewed by others

References

  1. H Roehrig J Far T Furukawa (.) Performance evaluation of LCD displays. HU Lemke MW Vannier K Inamura (Eds) et al. . CARS/Springer-Verlag New York

    Google Scholar 

  2. American Association of Physicists in Medicine (AAPM) Task Group-18. “Assessment of Display Performance for Medical Image,” 2002

  3. Planar Inc. Technology: 2003 http://www.planar.com/technology

  4. Y He J Kanicki et al. (2000) ArticleTitleHigh-efficiency organic polymer light-emitting heterostructure devices on flexible plastic substrates. Appl Physics Lett 76 661–663 Occurrence Handle10.1063/1.125854 Occurrence Handle1:CAS:528:DC%2BD3cXovV2ktA%3D%3D

    Article  CAS  Google Scholar 

  5. Grayscale Standard Display Function DICOM Part 14. National Electrical Manufacturer’s Association. Digital Imaging and Communication in Medicine (DICOM). Rosslyn, VA: NEMA, 2003; PS 3.14-3002

  6. VESA (Video Metronics Standards Association display metrology committee) “FLAT PANEL DISPLAY MEASUREMENTS STANDARD V.2”

  7. Klompenhouwer MA: Color Error Diffusion: Accurate Luminance from Coarsely Quantized Displays SID 01 Digest, 2001 Digest, 2001

  8. Flynn MF, Tchou P: Accurate measurement of monochrome luminance palettes for the calibration of medical LCD monitors, SPIE Medical Imaging; Visualization, Image-Guided Procedures and Display, Feb. 2003. SPIE Proc 5029, paper 47, 2003

  9. AD Ryer (1998) Light Measurement Handbook, International Light Newburyport, MA

    Google Scholar 

  10. PGJ Barten (1999) Contrast sensitivity of the human eye and its effects on image quality, SPIE Press .

    Google Scholar 

  11. WR Hendee PNT Wells (1997) The Perception of Visual Information, Springer-Verlag New York

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alice N. Averbukh M.S..

Rights and permissions

Reprints and permissions

About this article

Cite this article

Averbukh, A.N., Channin, D.S. & Flynn, M.J. Assessment of a Novel, High-Resolution, Color, AMLCD for Diagnostic Medical Image Display: Luminance Performance and DICOM Calibration. J Digit Imaging 16, 270–279 (2003). https://doi.org/10.1007/s10278-003-1718-z

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10278-003-1718-z

Keywords

Navigation