Skip to main content

Advertisement

Log in

Shaping ability of reciprocating single-file systems in severely curved canals: WaveOne and Reciproc versus WaveOne Gold and Reciproc blue

  • Original Article
  • Published:
Odontology Aims and scope Submit manuscript

Abstract

The aim was to compare the canal straightening of M-wire [Reciproc (VDW, Munich, Germany) and WaveOne (Dentsply Maillefer, Ballaigues, Switzerland)] and gold- and blue-wire heat-treated [Reciproc blue (VDW) and WaveOne Gold (Dentsply Maillefer)] instruments in severely curved root canals. A total of 80 root canals in extracted human teeth with angles of curvatures ranging between 25° and 35° and radii ranging between 3.1 and 8.5 mm were divided into four groups (n = 20). Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the radius of canal curvature (P = 1.0 and P = 1.0, respectively). All canals were prepared to an apical size 25 according to the manufacturers’ instructions. Pre- and post-instrumentation radiographs were superimposed and canal straightening was analysed using a computer imaging programme. Preparation time and instrument failure were also recorded. Data were analysed statistically using ANOVA and Student–Newman–Keuls test. During preparation no instrument fractured. All instruments maintained the original canal curvature well with no significant differences between the instruments (P = 0.278). Regarding preparation time, no significant differences between the four instruments were obtained (P > 0.05). Under the conditions of this study, all instruments respected the original canal curvature well. Instruments were safe to use. The use of the gold- and blue-wire heat-treated instruments was not associated with an improved shaping ability.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Plotino G, Ahmed HM, Grande NM, Cohen S, Bukiet F. Current assessment of reciprocation in endodontic preparation: a comprehensive review—part II: properties and effectiveness. J Endod. 2015;41:1939–50.

    Article  Google Scholar 

  2. Bürklein S, Hinschitza K, Dammaschke T, Schäfer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J. 2012;45:449 – 61.

    Article  PubMed  Google Scholar 

  3. Pereira ES, Peixoto IF, Viana AC, Oliveira II, Gonzalez BM, Buono VT, Bahia MG. Physical and mechanical properties of a thermomechanically treated NiTi wire used in the manufacture of rotary endodontic instruments. Int Endod J. 2012;45:469 – 74.

    Article  Google Scholar 

  4. Alapati SB, Brantley WA, Iijima M, Clark WA, Kovarik L, Buie C, Liu J, Ben Johnson W. Metallurgical characterization of a new nickel–titanium wire for rotary endodontic instruments. J Endod. 2009;35:1589–93.

    Article  PubMed  Google Scholar 

  5. Pereira ES, Viana AC, Buono VT, Peters OA, Bahia MG. Behavior of nickel–titanium instruments manufactured with different thermal treatments. J Endod. 2015;41:67–71.

    Article  Google Scholar 

  6. Gao Y, Gutmann JL, Wilkinson K, Maxwell R, Ammon D. Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments. J Endod. 2012;38:398–401.

    Article  Google Scholar 

  7. Al-Hadlaq SM, Aljarbou FA, AlThumairy RI. Evaluation of cyclic flexural fatigue of M-wire nickel-titanium rotary instruments. J Endod. 2010;36:305–7.

    Article  Google Scholar 

  8. Braga LC, Faria Silva AC, Buono VT, de Azevedo Bahia MG. Impact of heat treatments on the fatigue resistance of different rotary nickel–titanium instruments. J Endod. 2014;40:1494–7.

    Article  Google Scholar 

  9. Gambarini G, Rubini AG, Al Sudani D, et al. Influence of different angles of reciprocation on the cyclic fatigue of nickel–titanium endodontic instruments. J Endod. 2012;38:1408–11.

    Article  Google Scholar 

  10. Pedullà E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel–titanium rotary instruments. J Endod. 2013;39:258–61.

    Article  Google Scholar 

  11. Zanesco C, Só MV, Schmidt S, Fontanella VR, Grazziotin-Soares R, Barletta FB. Apical transportation, centering ratio, and volume increase after manual, rotary, and reciprocating instrumentation in curved root canals: analysis by micro-computed tomographic and digital subtraction radiography. J Endod. 2017;43:486 – 90.

    Article  PubMed  Google Scholar 

  12. Martinho FC, Freitas LF, Nascimento GG, Fernandes AM, Leite FR, Gomes AP, Camões IC. Endodontic retreatment: clinical comparison of reciprocating systems versus rotary system in disinfecting root canals. Clin Oral Investig. 2015;19:1411–7.

    Article  PubMed  Google Scholar 

  13. Ferrer-Luque CM, Bejarano I, Ruiz-Linares M, Baca P. Reduction in Enterococcus faecalis counts—a comparison between rotary and reciprocating systems. Int Endod J. 2014;47:380–6.

    Article  PubMed  Google Scholar 

  14. de Brito PRR, Lima PM, Nogueira LS, Emmanuel J, Fidel SR, Fidel RAS, Sassone LM. Effectiveness of ProTaper Next, ProTaper Universal and WaveOne systems in reducing intracanal bacterial load. ENDO (Lond Engl). 2016;10:167–73.

    Google Scholar 

  15. Maini HK, Dodd M, Blundell K, Burnside G, Jarad FD. Technical quality of root canal preparation with novice operators—reciprocation compared with continuous rotary motion. ENDO (Lond Engl). 2017;11:183–8.

    Google Scholar 

  16. Topçuoğlu HS, Düzgün S, Aktı A, Topçuoğlu G. Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature. Int Endod J. 2017;50:713–7.

    Article  Google Scholar 

  17. De-Deus G, Silva EJ, Vieira VT, Belladonna FG, Elias CN, Plotino G, Grande NM. Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the Reciproc files. J Endod. 2017;43:462–6.

    Article  Google Scholar 

  18. Hieawy A, Haapasalo M, Zhou H, Wang ZJ, Shen Y. Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper Universal Instruments. J Endod. 2015;41:1134–8.

    Article  Google Scholar 

  19. Duke F, Shen Y, Zhou H, Ruse ND, Wang ZJ, Hieawy A, Haapasalo M. Cyclic fatigue of ProFile Vortex and Vortex Blue nickel–titanium files in single and double curvatures. J Endod. 2015;41:1686–90.

    Article  Google Scholar 

  20. Elsaka SE, Elnaghy AM, Badr AE. Torsional and bending resistance of WaveOne Gold, Reciproc and twisted file adaptive instruments. Int Endod J. 2016. https://doi.org/10.1111/iej.12728 (in press).

    Article  PubMed  Google Scholar 

  21. Elnaghy AM, Elsaka SE. Mechanical properties of ProTaper Gold nickel–titanium rotary instruments. Int Endod J. 2016;49:1073–8.

    Article  PubMed  Google Scholar 

  22. Özyürek T. Cyclic fatigue resistance of Reciproc, WaveOne, and WaveOne Gold nickel–titanium instruments. J Endod. 2016;42:1536–9.

    Article  Google Scholar 

  23. Adıgüzel M, Capar ID. Comparison of cyclic fatigue resistance of WaveOne and WaveOne Gold small, primary, and large instruments. J Endod. 2017;43:623–7.

    Article  Google Scholar 

  24. Keskin C, Inan U, Demiral M, Keleş A. Cyclic fatigue resistance of Reciproc Blue, Reciproc, and WaveOne Gold reciprocating instruments. J Endod. 2017;43:1360–3.

    Article  Google Scholar 

  25. Schäfer E, Diez C, Hoppe W, Tepel J. Roentgenographic investigation of frequency and degree of canal curvatures in human permanent teeth. J Endod. 2002;28:211–6.

    Article  Google Scholar 

  26. Hülsmann M. Research that matters—canal preparation, retreatment and working length studies. Editorial Int Endod J. 2013;46:293–5.

    Article  PubMed  Google Scholar 

  27. Shen YA, Cheung GSP. Methods and models to study nickel-titanium instruments. Endod. Top. 2013;29:18–41.

    Article  Google Scholar 

  28. Bürklein S, Jäger PG, Schäfer E. Apical transportation and canal straightening with different continuously tapered rotary file systems in severely curved root canals: F6 SkyTaper and OneShape versus Mtwo. Int Endod J. 2017;50:983 – 90.

    Article  PubMed  Google Scholar 

  29. D’Amario M, Baldi M, Petricca R, De Angelis F, El Abed R, D’Arcangelo C. Evaluation of a new nickel-titanium system to create the glide path in root canal preparation of curved canals. J Endod. 2013;39:1581–4.

    Article  PubMed  Google Scholar 

  30. Alves Vde O, Bueno CE, Cunha RS, Pinheiro SL, Fontana CE, de Martin AS. Comparison among manual instruments and PathFile and Mtwo rotary instruments to create a glide path in the root canal preparation of curved canals. J Endod. 2012;38:117 – 20.

    Article  PubMed  Google Scholar 

  31. Saber SE, Nagy MM, Schäfer E. Comparative evaluation of the shaping ability of WaveOne, Reciproc and OneShape single-file systems in severely curved root canals of extracted teeth. Int Endod J. 2015;48:109–14.

    Article  PubMed  Google Scholar 

  32. Bürklein S, Benten S, Schäfer E. Shaping ability of different single-file systems in severely curved root canals of extracted teeth. Int Endod J. 2013;46:590–7.

    Article  PubMed  Google Scholar 

  33. Mamede-Neto I, Borges AH, Guedes OA, de Oliveira D, Pedro FL, Estrela C. Root canal transportation and centering ability of nickel–titanium rotary instruments in mandibular premolars assessed using cone-beam computed tomography. Open Den J. 2017;11:71–8.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Edgar Schäfer.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bürklein, S., Flüch, S. & Schäfer, E. Shaping ability of reciprocating single-file systems in severely curved canals: WaveOne and Reciproc versus WaveOne Gold and Reciproc blue. Odontology 107, 96–102 (2019). https://doi.org/10.1007/s10266-018-0364-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10266-018-0364-3

Keywords

Navigation