Abstract
The aim was to compare the canal straightening of M-wire [Reciproc (VDW, Munich, Germany) and WaveOne (Dentsply Maillefer, Ballaigues, Switzerland)] and gold- and blue-wire heat-treated [Reciproc blue (VDW) and WaveOne Gold (Dentsply Maillefer)] instruments in severely curved root canals. A total of 80 root canals in extracted human teeth with angles of curvatures ranging between 25° and 35° and radii ranging between 3.1 and 8.5 mm were divided into four groups (n = 20). Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the radius of canal curvature (P = 1.0 and P = 1.0, respectively). All canals were prepared to an apical size 25 according to the manufacturers’ instructions. Pre- and post-instrumentation radiographs were superimposed and canal straightening was analysed using a computer imaging programme. Preparation time and instrument failure were also recorded. Data were analysed statistically using ANOVA and Student–Newman–Keuls test. During preparation no instrument fractured. All instruments maintained the original canal curvature well with no significant differences between the instruments (P = 0.278). Regarding preparation time, no significant differences between the four instruments were obtained (P > 0.05). Under the conditions of this study, all instruments respected the original canal curvature well. Instruments were safe to use. The use of the gold- and blue-wire heat-treated instruments was not associated with an improved shaping ability.
Similar content being viewed by others
References
Plotino G, Ahmed HM, Grande NM, Cohen S, Bukiet F. Current assessment of reciprocation in endodontic preparation: a comprehensive review—part II: properties and effectiveness. J Endod. 2015;41:1939–50.
Bürklein S, Hinschitza K, Dammaschke T, Schäfer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J. 2012;45:449 – 61.
Pereira ES, Peixoto IF, Viana AC, Oliveira II, Gonzalez BM, Buono VT, Bahia MG. Physical and mechanical properties of a thermomechanically treated NiTi wire used in the manufacture of rotary endodontic instruments. Int Endod J. 2012;45:469 – 74.
Alapati SB, Brantley WA, Iijima M, Clark WA, Kovarik L, Buie C, Liu J, Ben Johnson W. Metallurgical characterization of a new nickel–titanium wire for rotary endodontic instruments. J Endod. 2009;35:1589–93.
Pereira ES, Viana AC, Buono VT, Peters OA, Bahia MG. Behavior of nickel–titanium instruments manufactured with different thermal treatments. J Endod. 2015;41:67–71.
Gao Y, Gutmann JL, Wilkinson K, Maxwell R, Ammon D. Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments. J Endod. 2012;38:398–401.
Al-Hadlaq SM, Aljarbou FA, AlThumairy RI. Evaluation of cyclic flexural fatigue of M-wire nickel-titanium rotary instruments. J Endod. 2010;36:305–7.
Braga LC, Faria Silva AC, Buono VT, de Azevedo Bahia MG. Impact of heat treatments on the fatigue resistance of different rotary nickel–titanium instruments. J Endod. 2014;40:1494–7.
Gambarini G, Rubini AG, Al Sudani D, et al. Influence of different angles of reciprocation on the cyclic fatigue of nickel–titanium endodontic instruments. J Endod. 2012;38:1408–11.
Pedullà E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel–titanium rotary instruments. J Endod. 2013;39:258–61.
Zanesco C, Só MV, Schmidt S, Fontanella VR, Grazziotin-Soares R, Barletta FB. Apical transportation, centering ratio, and volume increase after manual, rotary, and reciprocating instrumentation in curved root canals: analysis by micro-computed tomographic and digital subtraction radiography. J Endod. 2017;43:486 – 90.
Martinho FC, Freitas LF, Nascimento GG, Fernandes AM, Leite FR, Gomes AP, Camões IC. Endodontic retreatment: clinical comparison of reciprocating systems versus rotary system in disinfecting root canals. Clin Oral Investig. 2015;19:1411–7.
Ferrer-Luque CM, Bejarano I, Ruiz-Linares M, Baca P. Reduction in Enterococcus faecalis counts—a comparison between rotary and reciprocating systems. Int Endod J. 2014;47:380–6.
de Brito PRR, Lima PM, Nogueira LS, Emmanuel J, Fidel SR, Fidel RAS, Sassone LM. Effectiveness of ProTaper Next, ProTaper Universal and WaveOne systems in reducing intracanal bacterial load. ENDO (Lond Engl). 2016;10:167–73.
Maini HK, Dodd M, Blundell K, Burnside G, Jarad FD. Technical quality of root canal preparation with novice operators—reciprocation compared with continuous rotary motion. ENDO (Lond Engl). 2017;11:183–8.
Topçuoğlu HS, Düzgün S, Aktı A, Topçuoğlu G. Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature. Int Endod J. 2017;50:713–7.
De-Deus G, Silva EJ, Vieira VT, Belladonna FG, Elias CN, Plotino G, Grande NM. Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the Reciproc files. J Endod. 2017;43:462–6.
Hieawy A, Haapasalo M, Zhou H, Wang ZJ, Shen Y. Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper Universal Instruments. J Endod. 2015;41:1134–8.
Duke F, Shen Y, Zhou H, Ruse ND, Wang ZJ, Hieawy A, Haapasalo M. Cyclic fatigue of ProFile Vortex and Vortex Blue nickel–titanium files in single and double curvatures. J Endod. 2015;41:1686–90.
Elsaka SE, Elnaghy AM, Badr AE. Torsional and bending resistance of WaveOne Gold, Reciproc and twisted file adaptive instruments. Int Endod J. 2016. https://doi.org/10.1111/iej.12728 (in press).
Elnaghy AM, Elsaka SE. Mechanical properties of ProTaper Gold nickel–titanium rotary instruments. Int Endod J. 2016;49:1073–8.
Özyürek T. Cyclic fatigue resistance of Reciproc, WaveOne, and WaveOne Gold nickel–titanium instruments. J Endod. 2016;42:1536–9.
Adıgüzel M, Capar ID. Comparison of cyclic fatigue resistance of WaveOne and WaveOne Gold small, primary, and large instruments. J Endod. 2017;43:623–7.
Keskin C, Inan U, Demiral M, Keleş A. Cyclic fatigue resistance of Reciproc Blue, Reciproc, and WaveOne Gold reciprocating instruments. J Endod. 2017;43:1360–3.
Schäfer E, Diez C, Hoppe W, Tepel J. Roentgenographic investigation of frequency and degree of canal curvatures in human permanent teeth. J Endod. 2002;28:211–6.
Hülsmann M. Research that matters—canal preparation, retreatment and working length studies. Editorial Int Endod J. 2013;46:293–5.
Shen YA, Cheung GSP. Methods and models to study nickel-titanium instruments. Endod. Top. 2013;29:18–41.
Bürklein S, Jäger PG, Schäfer E. Apical transportation and canal straightening with different continuously tapered rotary file systems in severely curved root canals: F6 SkyTaper and OneShape versus Mtwo. Int Endod J. 2017;50:983 – 90.
D’Amario M, Baldi M, Petricca R, De Angelis F, El Abed R, D’Arcangelo C. Evaluation of a new nickel-titanium system to create the glide path in root canal preparation of curved canals. J Endod. 2013;39:1581–4.
Alves Vde O, Bueno CE, Cunha RS, Pinheiro SL, Fontana CE, de Martin AS. Comparison among manual instruments and PathFile and Mtwo rotary instruments to create a glide path in the root canal preparation of curved canals. J Endod. 2012;38:117 – 20.
Saber SE, Nagy MM, Schäfer E. Comparative evaluation of the shaping ability of WaveOne, Reciproc and OneShape single-file systems in severely curved root canals of extracted teeth. Int Endod J. 2015;48:109–14.
Bürklein S, Benten S, Schäfer E. Shaping ability of different single-file systems in severely curved root canals of extracted teeth. Int Endod J. 2013;46:590–7.
Mamede-Neto I, Borges AH, Guedes OA, de Oliveira D, Pedro FL, Estrela C. Root canal transportation and centering ability of nickel–titanium rotary instruments in mandibular premolars assessed using cone-beam computed tomography. Open Den J. 2017;11:71–8.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Bürklein, S., Flüch, S. & Schäfer, E. Shaping ability of reciprocating single-file systems in severely curved canals: WaveOne and Reciproc versus WaveOne Gold and Reciproc blue. Odontology 107, 96–102 (2019). https://doi.org/10.1007/s10266-018-0364-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10266-018-0364-3