Skip to main content

Advertisement

Log in

The influence of mechanical stimulation on osteoclast localization in the mouse maxilla: bone histomorphometry and finite element analysis

  • Original Paper
  • Published:
Biomechanics and Modeling in Mechanobiology Aims and scope Submit manuscript

Abstract

The mechanism of traumatic bone resorption in the denture-bearing bone has not yet been established with regard to the osteoclastic activity in relation to the mechanical stimulus. The purpose of this study was to clarify whether osteoclast appearance in maxilla depends on the strain intensity, using the murine loading model. The maxillary palate of thirteen-week-old male C57BL/6 mice was subjected to continuous pressure of 2 kPa (low stimulation, n = 4) or 7 kPa (high stimulation, n = 4) for 30 min/day for 7 consecutive days, and the mice were sacrificed after the last loading. The control group underwent the same protocol without load (n = 4). An animal-specific finite element model was constructed based on morphology and characteristics obtained from the micro-CT data and used to calculate the strain intensity of the bone. The bone histomorphometric technique revealed significant reduction of cortical bone volume and significant increase of bone resorption parameters such as osteoclast number in the bone tissue under the loading contact in comparison to the control (p < 0.05). The osteoclasts were observed in the subsurface region adjacent to the loading contact and the peripheral region of the marrow space in the intracortical region of the cortical bone in the mouse maxilla in both stimulation groups. An average of more than 90 % of the osteoclasts was observed in the areas with strain intensity higher than 85.0μ strain for the high stimulation group. The result suggests that the osteoclastic resorption is location-dependent and is also sensitive to the local strain intensity.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Aoki K, Saito H, Itzstein C, Ishiguro M, Shibata T, Blanque R, Mian AH, Takahashi M, Suzuki Y, Yoshimatsu M, Yamaguchi A, Deprez P, Mollat P, Murali R, Ohya K, Horne WC, Baron R (2006) A TNF receptor loop peptide mimic blocks RANK ligand-induced signaling, bone resorption, and bone loss. J Clin Invest 116: 1525–1534. doi:10.1172/JCI22513

    Article  Google Scholar 

  • Bergman B, Carlsson GE (1985) Clinical long-term study of complete denture wearers. J Prosthet Dent 53: 56–61

    Article  Google Scholar 

  • Bonewald LF, Johnson ML (2008) Osteocytes, mechanosensing and Wnt signaling. Bone 42: 606–615

    Article  Google Scholar 

  • Bourrin S, Palle S, Genty C, Alexandre C (1995) Physical exercise during remobilization restores a normal bone trabecular network after tail suspension-induced osteopenia in young rats. J Bone Miner Res 10: 820–828

    Article  Google Scholar 

  • Brunski JB (1999) In vivo bone response to biomechanical loading at the bone/dental-implant interface. Adv Dent Res 13: 99–119

    Article  Google Scholar 

  • Carlsson GE (1998) Clinical morbidity and sequelae of treatment with complete dentures. J Prosthet Dent 79: 17–23

    Article  MathSciNet  Google Scholar 

  • Frost HM (1987) Bone “mass” and the “mechanostat”: a proposal. Anat Rec 219: 1–9

    Article  Google Scholar 

  • Frost HM (1994) Wolff’s law and bone’s structural adaptations to mechanical usage: an overview for clinicians. Angle Orthod 64: 175–188

    Google Scholar 

  • Haraldson T, Karlsson U, Carlsson GE (1979) Bite force and oral function in complete denture wearers. J Oral Rehabil 6: 41–48

    Article  Google Scholar 

  • Harrison NM, McDonnell PF, O’Mahoney DC, Kennedy OD, O’Brien FJ, McHugh PE (2008) Heterogeneous linear elastic trabecular bone modelling using micro-CT attenuation data and experimentally measured heterogeneous tissue properties. J Biomech 41: 2589–2596

    Article  Google Scholar 

  • Imai Y, Sato T, Mori S, Okamoto M (2002) A histomorphometric analysis on bone dynamics in denture supporting tissue under continuous pressure. J Oral Rehabil 29: 72–79

    Article  Google Scholar 

  • Kadow-Romacker A, Hoffmann JE, Duda G, Wildemann B, Schmidmaier G (2009) Effect of mechanical stimulation on osteoblast- and osteoclast-like cells in vitro. Cells Tissues Organs 190: 61–68

    Article  Google Scholar 

  • Kingsmill VJ, Boyde A, Davis GR, Howell PGT, Rawlinson SCF (2010) Changes in bone mineral and matrix in response to a soft diet. J Dent Res 89: 510–514

    Article  Google Scholar 

  • Knothe UR, Dolejs S, Matthew Miller R, Knothe Tate ML (2010) Effects of mechanical loading patterns, bone graft, and proximity to periosteum on bone defect healing. J Biomech 43: 2728–2737

    Article  Google Scholar 

  • Lanyon L (2008) Strain-related control of bone (re)modeling: objectives, mechanisms and failures. J Musculoskelet Neuronal Interact 8: 298–300

    Google Scholar 

  • Lanyon LE (1992) Control of bone architecture by functional load bearing. J Bone Miner Res 7(Suppl 2): S369–S375

    Article  Google Scholar 

  • Maruo Y, Nishigawa G, Irie M, Oka M, Hara T, Suzuki K, Minagi S (2010) Stress distribution prevents ischaemia and bone resorption in residual ridge. Arch Oral Biol 55: 873–878

    Article  Google Scholar 

  • Mori S, Sato T, Hara T, Nakashima K, Minagi S (1997) Effect of continuous pressure on histopathological changes in denture-supporting tissues. J Oral Rehabil 24: 37–46

    Article  Google Scholar 

  • Mosley JR, Lanyon LE (1998) Strain rate as a controlling influence on adaptive modeling in response to dynamic loading of the ulna in growing male rats. Bone 23: 313–318

    Article  Google Scholar 

  • Muller F, Hernandez M, Grutter L, Aracil-Kessler L, Weingart D, Schimmel M (2011) Masseter muscle thickness, chewing efficiency and bite force in edentulous patients with fixed and removable implant-supported prostheses: a cross-sectional multicenter study. Clin Oral Implants Res 23: 144–150. doi:10.1111/j.1600-0501

    Article  Google Scholar 

  • Mulvihill BM, Prendergast PJ (2010) Mechanobiological regulation of the remodeling cycle in trabecular bone and possible biomechanical pathways for osteoporosis. Clin Biomech 25: 491–498

    Article  Google Scholar 

  • Nagano K, Alles N, Mian AH, Shimoda A, Morimoto N, Tamura Y, Shimokawa H, Akiyoshi K, Ohya K, Aoki K (2011) The tumor necrosis factor type 2 receptor plays a protective role in tumor necrosis factor-alpha-induced bone resorption lacunae on mouse calvariae. J Bone Miner Metab 29: 671–681. doi:10.1007/s00774-011-0270-z

    Article  Google Scholar 

  • Nicolella DP, Bonewald LF, Moravits DE, Lankford J (2005) Measurement of microstructural strain in cortical bone. Eur J Morphol 42: 23–29

    Article  Google Scholar 

  • Noble BS, Reeve J (2000) Osteocyte function, osteocyte death and bone fracture resistance. Mol Cell Endocrinol 159: 7–13

    Article  Google Scholar 

  • Nozaki K, Kaku M, Yamashita Y, Yamauchi M, Miura H (2010) Effect of cyclic mechanical loading on osteoclast recruitment in periodontal tissue. J Periodont Res 45: 8–15

    Article  Google Scholar 

  • Parfitt AM, Drezner MK, Glorieux FH, Kanis JA, Malluche H, Meunier PJ, Ott SM, Recker RR (1987) Bone histomorphometry: standardization of nomenclature, symbols, and units. Report of the ASBMR Histomorphometry Nomenclature Committee. J Bone Miner Res 2: 595–610

    Article  Google Scholar 

  • Rochefort GY, Pallu S, Benhamou CL (2010) Osteocyte: the unrecognized side of bone tissue. Osteoporos Int 21: 1457–1469

    Article  Google Scholar 

  • Rudolph DJ, Willes PMG, Sameshima GT (2001) A finite element model of apical force distribution from orthodontic tooth movement. Angle Orthod 71: 127–131

    Google Scholar 

  • Saito H, Kojima T, Takahashi M, Horne WC, Baron R, Amagasa T, Ohya K, Aoki K (2007) A tumor necrosis factor receptor loop peptide mimic inhibits bone destruction to the same extent as anti-tumor necrosis factor monoclonal antibody in murine collagen-induced arthritis. Arthritis Rheum 56: 1164–1174

    Article  Google Scholar 

  • Sato T, Hara T, Mori S, Shirai H, Minagi S (1998) Threshold for bone resorption induced by continuous and intermittent pressure in the rat hard palate. J Dent Res 77: 387–392

    Article  Google Scholar 

  • Shefelbine SJ, Simon U, Claes L, Gold A, Gabet Y, Bab I, Muller R, Augat P (2005) Prediction of fracture callus mechanical properties using micro-CT images and voxel-based finite element analysis. Bone 36: 480–488

    Article  Google Scholar 

  • Tallgren A (2003) The continuing reduction of the residual alveolar ridges in complete denture wearers: a mixed-longitudinal study covering 25 years. J Prosthet Dent 89: 427–435

    Article  Google Scholar 

  • Turner CH, Forwood MR, Otter MW (1994) Mechanotransduction in bone: do bone cells act as sensors of fluid flow?. FASEB J 8: 875–878

    Google Scholar 

  • Verborgt O, Gibson GJ, Schaffler MB (2000) Loss of osteocyte integrity in association with microdamage and bone remodeling after fatigue in vivo. J Bone Miner Res 15: 60–67

    Article  Google Scholar 

  • Waldorff EI, Christenson KB, Cooney LA, Goldstein SA (2010) Microdamage repair and remodeling requires mechanical loading. J Bone Miner Res 25: 734–745

    Google Scholar 

  • Xie Q, Ainamo A, Tilvis R (1997) Association of residual ridge resorption with systemic factors in home-living elderly subjects. Acta Odontol Scand 55: 299–305

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to N. Wakabayashi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fujiki, K., Aoki, K., Marcián, P. et al. The influence of mechanical stimulation on osteoclast localization in the mouse maxilla: bone histomorphometry and finite element analysis. Biomech Model Mechanobiol 12, 325–333 (2013). https://doi.org/10.1007/s10237-012-0401-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10237-012-0401-z

Keywords

Navigation