Skip to main content
Log in

Effects of Diode Laser Therapy on Blood Flow in Axial Pattern Flaps in the Rat Model

  • Regular Article
  • Published:
Lasers in Medical Science Aims and scope Submit manuscript

Abstract

Axial pattern skin flaps are a very important reparative tool for the plastic and reconstructive surgeon in the reconstruction of tissue defects. From whatever unfortunate reason, part or all of such flaps occasionally suffers from irreversible ischaemia with loss of the flap. Infrared diode laser therapy has been shown to improve local and systemic circulation. The present study was designed to assess the effect of an 830 nm diode laser (power density, 18.5 W/cm2, energy density 185 J/cm2) on the blood flow of axial pattern flaps in the rat model and their survival, compared with unirradiated controls. The flaps were raised in all animals (n=40), and blood flow assessed with laser speckle flowmetry (LSF). In the experimental groups (3 groups, n=10 per group), the flaps were irradiated either directly over the dominant feeder vessel (iliolumbar artery), at the proximal end or at the distal end of the flap itself and blood flow assessed during irradiation. Flowmetry was performed again in all animals at 5 and 10 min postirradiation, and the flaps sutured back in position. The unirradiated controls were handled in exactly the same way, but the laser was not activated. The survival rate of the flaps was assessed on the fifth postoperative day. LSF demonstrated significant increased blood flow in the flaps at 5 and 10 min postirradiation in all experimental groups compared with the control animals. At five days postirradiation, there was significantly better survival of the flaps in all the experimental groups compared with the controls (p<0.01), but no significant difference was seen between any of the experimental groups. We conclude that laser therapy increases the blood flow and perfusion of transferred flaps, and that this has significant effects on the survival of the flaps. One possible mechanism of modulation of the autonomic nervous system is discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Paper received 19 March 2001; accepted after revision 28 September 2001.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kubota, J. Effects of Diode Laser Therapy on Blood Flow in Axial Pattern Flaps in the Rat Model. Lasers Med Sci 17, 146–153 (2002). https://doi.org/10.1007/s101030200024

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s101030200024

Navigation