Abstract
Different devices have been used to enhance topical drug delivery. Aim of this study was to compare the efficacy of different skin pretreatment regimens in topical drug delivery. In six ex vivo human abdominal skin samples, test regions were pretreated with fractional CO2 and Er:YAG laser (both 70 and 300 μm ablation depth, density of 5%), microneedling (500 μm needle length), fractional radiofrequency (ablation depth of ± 80–90 μm), and no pretreatment. The fluorescent agent indocyanine green (ICG) was applied. After 3 h, fluorescence intensity was measured at several depths using fluorescence photography. Significantly higher surface fluorescence intensities were found for pretreatment with fractional Er:YAG and CO2 laser and for microneedling vs. no pretreatment (p < 0.05), but not for radiofrequency vs. no pretreatment (p = 0.173). Fluorescence intensity was highest for the Er:YAG laser with 300 μm ablation depth (mean 38.89 arbitrary units; AU), followed by microneedling (33.02 AU) and CO2 laser with 300 μm ablation depth (26.25 AU). Pretreatment with both lasers with 300 μm ablation depth gave higher fluorescence intensity than with 70 μm ablation depth (Er:YAG laser, 21.65; CO2 laser, 18.50 AU). Mean fluorescence intensity for radiofrequency was 15.27 AU. Results were comparable at 200 and 400 μm depth in the skin. Pretreatment of the skin with fractional CO2 laser, fractional Er:YAG laser, and microneedling is effective for topical ICG delivery, while fractional radiofrequency is not. Deeper laser ablation results in improved ICG delivery. These findings may be relevant for the delivery of other drugs with comparable molecular properties.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Pretreatment of the skin with an ablative fractional laser is an effective method to enhance topical drug uptake in the skin, and this fractional laser-assisted drug delivery has become a well-established treatment modality [1, 2]. This technique acts by the principle of fractional disruption of the epidermis, creating an array of microscopic holes in the skin through which topical drugs can be delivered, with minimal risk of scarring [3]. For ablative fractional laser-assisted topical drug delivery, mainly carbon dioxide (CO2) lasers and Erbium Yttrium Aluminum Garnet (Er:YAG) lasers are used. Fractional CO2 lasers are generally believed to produce a significant necrotic eschar and a thick coagulation zone surrounding each ablation channel, whereas Er:YAG lasers produce a thinner coagulation zone, which may facilitate drug permeation, but might also be associated with more exudate formation impairing drug uptake [4,5,6]. Beside ablative fractional laser, other fractional techniques, including microneedling and fractional radiofrequency, have been investigated for the purpose of cutaneous drug delivery [7, 8]. Microneedling mechanically disrupts the epidermis by insertion of a grid of microscopic needles, while radiofrequency techniques produce plasma sparks that induce fractional epidermal ablation. To date, studies directly comparing these different pretreatment techniques are rare [9].
Aim of this study was to compare the accumulation of the fluorescent agent indocyanine green (ICG) as a representative drug model, in ex vivo human skin after pretreatment of the skin with a fractional CO2 laser, fractional Er:YAG laser, microneedling, or fractional radiofrequency (RF) device.
Materials and methods
Study design
The study evaluated the accumulation of fluorescence of ICG in 5 × 5 mm test regions in ex vivo human abdominal skin samples pretreated with fractional CO2 laser, fractional Er:YAG laser, microneedling, or fractional RF. ICG was left in place for 3 h. After application time, distribution and fluorescence intensity of ICG in the skin were assessed using digital surface fluorescence photography. Main outcome parameter was fluorescence intensity of ICG in the intact skin.
Skin samples
Samples were consisted of excised human abdominoplasty skin and were collected at the department of plastic surgery at the Slotervaart Hospital in Amsterdam. In total, six skin samples from six individual patients were used. The use of skin from the Slotervaart Hospital for these experiments was approved by AMC Medical Ethics Committee officials. As skin samples were anonymized, a formal review procedure of the protocol by the Medical Ethics Committee was not required. Skin samples were stored and prepared according to a standardized protocol published earlier [10].
Lasers
Two fractional ablative lasers were used: a fractional 10,600 nm CO2 laser (Ultrapulse®, DeepFx handpiece; Lumenis Inc., Santa Clara, CA, USA) and a fractional 2940 nm Er:YAG laser (P.L.E.A.S.E.® Professional, Pantec Biosolutions, Rugell, Liechtenstein). Pretreatment with the CO2 and Er:YAG laser were compared at two different pulse energy settings corresponding to two different predetermined laser channel depths (Fig. 1), 70 μm and 300 μm. Optical coherence tomography (OCT) was used in order to optimize settings that created laser channels of equal depths for both lasers (Figs. 1 and 2). 2D and 3D images were acquired using a commercial swept source system (Santec Inner Vision 2000, Santec Corporation, Komaki, Japan) operating at 1300 nm central wavelength at 50 kHz, with an experimentally determined axial resolution of 13 μm in tissue and lateral resolution of 25 μm. The OCT measurements were performed in triplicate for each laser setting.
The CO2 laser was set at 2.5 mJ/microbeam and at 20 mJ/microbeam (600 Hz; pulse duration 80 μs, density 5%, 1 pulse, scanned area 5 × 5 mm, microspot size 120 μm) to create channels of 70 μm and 300 μm depth, respectively. The Er:YAG laser was set at 9 mJ/microbeam (0.9 W, 1 pulse duration:225 μs, density 5%, scanned area 5 × 5 mm, microspot size 225 μm). To create channels of 70 μm and 300 μm depth, one or nine stacked pulses (stacking frequency 100 Hz) were used, respectively.
Microneedling
As a microneedling device, the Dermaroller 180 was used, containing 180 titanium needles with a length of 500 μm. The microneedling device was rolled 8 times across the skin in vertical, horizontal, and oblique directions, according to the manufacturer’s instructions.
Radiofrequency
For RF, two passes with the LegatoII Pixel RF ™ at 60 W (Alma Lasers Ltd., handpiece: rolling tip, Nuremburg, Germany) were used, according to the manufacturer’s instructions. Ablation depth at these settings is approximately 80–90 μm and ablation width 220 μm [11].
Indocyanine green
The fluorescent agent ICG (Cardiogreen, Sigma-Aldrich, St. Louis, MO, USA) was used as an indicator of drug absorption in the skin through the fractional laser ablation channels. ICG is a hydrophilic drug (Log P − 0.29) with a molecular weight of 775 Da. ICG was diluted with demineralized water to a concentration of 0.08 mg/ml according to the protocol published in our earlier study [10].
A total of 0.1 ml of ICG was occluded under a coverslip at each test region. During the application time, ICG was kept under dark circumstances by covering the skin samples with aluminum foil. At the end of the application time, excess ICG was wiped off from the skin.
Fluorescence photography
Fluorescence of ICG in the skin was assessed using digital surface fluorescence photography performed in a dark environment to minimize exposure by ambient light. A 780-nm continuous wave diode laser was used as excitation source, and photographs were taken with a long pass cut-on 850-nm filter to block the excitation light and transmit an adequate amount of the fluorescence light, mounted on a full spectrum-modified digital camera (Sony α 5000, 24 mm objective, F/6,5, ISO 800, 10 s shutter speed) with a fixed focal distance. In order to achieve uniform light distribution of the diode laser on the test region, a diffuser was used. A reference point was incorporated in the corner of each photograph in order to correct for frame-to-frame variations. The reference point is consisted of a synthetic white diffusing bead on top of a fiber. The other end of the fiber was attached to an LED with an 810-nm peak emission generating a constant brightness at a fixed current/voltage.
Fluorescence images at skin surface, at 200 μm, and at 400 μm depth were collected. In order to enable imaging of deeper skin layers, the superficial skin layer was removed at the end of the application time by administering a pulse train with the CO2 laser (Acuspot 712, kamami tonsil tip, Lumenis Inc., Santa Clara, CA, USA) at the following settings: focused, tonsil, spot size 2, depth 1, 25 (200 μm ablation depth), and 60 W (400 μm ablation depth). OCT was used to verify depth of the ablated skin layers at various laser settings. The Acuspot 712 at the chosen settings provided a uniform removal of skin layers with minimal carbonization. Carbonized skin could be easily wiped off with a nonwoven gauze.
Image analysis
Fluorescence images were analyzed using ImageJ (ImageJ 1.50i, National Institute of health, Bethesda, MD, USA). Fluorescence intensity was assessed at the skin surface, at 200 μm (upper reticular dermis), and at 400 μm (lower reticular dermis) depth by measuring gray value on a 0 to 255 arbitrary scale (0 representing black, 255 representing white). Mean fluorescence intensity was measured within a standardized circular area slightly smaller than the test region diameter (for the measurements in deeper skin layers, slightly smaller than the diameter of the full surface ablated area). Since the main outcome parameter was the fluorescence intensity in the intact skin (and not in the laser-induced coagulation zones surrounding the ablation channels, where mean fluorescence intensity is much higher), an additional measurement was performed for each test region pretreated with fractional CO2 and Er:YAG laser. In these additional measurements, the extreme values of fluorescence intensity found in the coagulation zones were filtered out by visual determination of a cut-off value of fluorescence intensity above which the measured values were excluded from calculation of the mean fluorescence intensity (Fig. 3). Images were corrected for autofluorescence of the skin by subtraction of the fluorescence intensity of the control image (no pretreatment, no ICG) at the skin surface, at 200 μm, and at 400 μm depth. Frame-to-frame variations were corrected for by the reference point.
Statistical analysis
The statistical analysis of the outcomes was performed using Statistical Package for the Social Sciences 23 (SPSS, Chicago, IL). All data were entered in the SPSS database. Means, medians, and interquartile ranges (IQR) were calculated. Wilcoxon signed rank test was used to compare paired data. The significance level was set at P < 0.05.
Results
Visual assessment of fluorescence
In the non-pretreated regions, surface fluorescence was very weak (Fig. 3). In the CO2 and Er:YAG laser pretreated regions, fluorescence was more intense and was mainly concentrated around the ablation channels, especially in the regions pretreated with the more aggressive laser energy settings. We assume that these areas of intense fluorescence correspond with the laser-induced coagulation zones. As stated above, fluorescence intensity in these supposed coagulation zones was excluded from the measurements of mean fluorescence intensity per test region. In the regions pretreated with microneedling, overall fluorescence also appeared more intense compared to the regions that did not receive pretreatment. The pattern of the insertion points of the needles could still be recognized, but fluorescence was less pronounced compared to the coagulation zones surrounding the CO2 and Er:YAG laser channels. In the RF pretreated sites, some irregular patchy areas of increased fluorescence were observed, whereas overall fluorescence was weak.
Removal of the superficial layer of the skin with the non-fractional CO2 laser enabled us to visualize the skin at various levels in the reticular dermis dependent on the laser settings (Fig. 4). At 200 μm depth, the pattern of the 300 μm deep CO2 and Er:YAG laser ablation channels ([CO2 300]; [Er:YAG 300]) was visible, with fluorescence mainly concentrated in the supposed coagulation zone. No channel pattern was visible at 200 μm depth at the test regions pretreated with the CO2 laser at low energy settings (70 μm ablation depth; [CO2 70]) with microneedling and with RF. The lowermost part of the coagulation zone of a few channels could be identified in some regions treated with the Er:YAG laser at low energy settings (70 μm ablation depth; [Er:YAG 70]). At 400 μm depth, the channel pattern could only be vaguely recognized in some of the [Er:YAG 300] test regions.
Assessment of fluorescence intensity
Skin surface fluorescence
Mean fluorescence intensities are displayed in Table 1. Fluorescence intensity was significantly higher for all test regions receiving any sort of pretreatment (Fig. 5a), compared to the control regions that did not receive pretreatment (10.40–48.19 arbitrary units [AU] vs. 4.65–14.64 AU; p < 0.05), except for RF (2.84–22.06 AU; p = 0.173). Mean fluorescence intensity was highest for the test regions pretreated with [Er:YAG 300], followed by microneedling, [CO2 300], [Er:YAG 70], [CO2 70], and RF, respectively. Fluorescence intensity was significantly higher for [Er:YAG 300], [CO2 300], and microneedling compared to [Er:YAG 70] and [CO2 70] and for [Er:YAG 300] compared to [CO2 300] (p < 0.05).
Deeper skin layers
Both at 200 and 400 μm depth, fluorescence intensity tended to be significantly higher for the test regions receiving fractional laser or microneedling pretreatment, compared to the regions that did not receive pretreatment (3.35–43.18 AU vs. 1.48–15.63 AU; p < 0.05; Fig. 5b and c). At the test regions pretreated with RF, no increase in fluorescence intensity (0.38–17.00 AU) was observed compared to the non-pretreated control regions (200 μm depth, p = 0.917; 400 μm depth, p = 0.345). Fluorescence intensity was highest for the test regions pretreated with [Er:YAG 300, followed by [CO2 300] and microneedling, followed by [Er:YAG 70] and [CO2 70], followed by RF. [Er:YAG 300] rendered higher fluorescence intensity compared to all other pretreatment methods. Fluorescence intensity was significantly higher for [Er:YAG 300], [CO2 300], and microneedling compared to [Er:YAG 70] and [CO2 70] (p < 0.05; except for [CO2 300] vs. [CO2 70] at 200 μm depth: p = 0.075).
Discussion
Our findings show that pretreatment with fractional CO2 laser, fractional Er:YAG laser, or microneedling enhances accumulation of ICG in the skin. We saw no significant increase in ICG accumulation following pretreatment with a fractional radiofrequency device. Low fractional laser energy settings, associated with very superficial ablation channels, appeared to be sufficient to achieve increased ICG accumulation, although ICG delivery was more effective through deeper channels. With the equipment and laser parameters used in this study, the Er:YAG laser that stacked several pulses appeared to be most effective. Microneedling with 500 μm long needles also resulted in increased accumulation of ICG, comparable to pretreatment with the fractional CO2 laser creating 300 μm deep ablation channels.
Studies comparing different ablative fractional laser modalities for the purpose of fractional laser-assisted drug delivery are still scarce. In 2018, we published a clinical study on fractional laser-assisted topical anesthesia, showing that pretreatment with fractional CO2 laser and fractional Er:YAG laser was comparably effective. With the low energy settings used in that study (channel depth 70 μm), these results are in line with our current findings. Classically, CO2 lasers are believed to create a wider coagulation zone than Er:YAG lasers since the 10,600 nm wavelength is less effectively absorbed by water than the 2940 nm wavelength [4]. However, we would like to stress that this dogmatic approach is often not feasible in practice, as ablation channel characteristics and coagulation zone width appear to be primarily determined by the combination of laser parameters chosen, especially pulse energy, pulse duration, and number of stacked pulses. According to an earlier study by Taudorf et al., the Er:YAG laser that was also used in the present study creates a coagulation zone of 30–40 μm at settings comparable to the 9 × 9 mJ/microbeam pulse energy settings used in our study [12]. According to earlier preliminary reflectance confocal microscopy images made at our institute, the fractional CO2 laser at 20 mJ/microbeam pulse energy induced coagulation zones that were of a similar width of 30–40 μm. In recent years, the importance of the fractional laser induced coagulation zone has been recognized. Where the coagulation zone was initially seen as a troublesome barrier for drug penetration, recent studies show that the presence of a thin coagulation zone of 20 μm actually facilitates drug delivery to the viable tissue [6, 13]. A thin coagulation zone prevents oozing and bleeding and may function as a reservoir through which drugs may be gradually released into the tissue.
In our present study, the fractional Er:YAG laser appeared to be more effective for the delivery of ICG than the fractional CO2 laser, when using relatively high energy settings (ablation channel depth: 300 μm). Possible explanations for this difference remain speculative. Although we were able to match the density and ablation channel depth between the CO2 laser and the Er:YAG laser, there were substantial differences in ablation channel width due to several factors including differences in microspot size (120 vs. 225 μm, respectively), more effective ablation at the Er:YAG laser wavelength (2940 nm), and possibly collapse of the ablation channels that are created in an explosive fashion by the ultrapulsed CO2 laser. As the Er:YAG laser creates larger ablation channels that may contain a larger volume of ICG, hydrostatic pressure of ICG within each channel is higher, whereas capillary action is smaller, which may facilitate penetration of ICG from the ablation channels into the skin. In earlier in vivo studies, microscopic regions of horizontal dissection have been observed after irradiation with pulsed mid-infrared lasers caused by laser-induced vapor bubble expansion. These regions can only be visualized after several days, when they are filled with blood [14]. Theoretically, this mechanism may be more important when using a laser that stacks several pulses, generating repeated micro bubbles. Subsequently, these dissected regions may make the skin more permeable for ICG, leading to higher tissue concentrations. This may also explain the differences in fluorescence intensity after pretreatment with the fractional Er:YAG laser and microneedling. In a study by Nguyen and Banga [7] assessing delivery of methotrexate after pretreatment with the same fractional Er:YAG laser as used in our study and a microneedling device, a similar difference between both modalities was found. The authors of this study acknowledge that both Er:YAG laser pretreatment and microneedling enhance skin delivery of methotrexate, although laser pretreatment delivered a significantly higher amount of drug into the skin. Interestingly, an earlier in vivo study by Bay et al. [9], comparing pretreatment with fractional CO2 laser, non-ablative fractional Er:glass laser, microneedling, and microdermabrasion, showed that pretreatment with fractional CO2 laser was more effective for delivery of protoporphyrin IX than microneedling. It should however be noted that in vivo microneedling may cause more bleeding or oozing of tissue fluid because of the absence of a coagulation zone. This may impair drug delivery and explain the suboptimal results compared to fractional CO2 laser pretreatment. Moreover, in microneedling, the skin is only disrupted without the formation of true ablation channels, as in fractional laser ablation. Therefore, microneedle-induced skin defects may be more likely to collapse in vivo compared to our tissue model where the skin was kept under constant tension.
Pretreatment with fractional laser resulted in much higher ICG fluorescence intensities than pretreatment with fractional RF. Fluorescence intensity at the test regions pretreated with RF was not significantly higher compared to unpretreated control. Studies showing increased drug delivery following fractional RF pretreatment of the skin go back as far as 2003 [8, 15, 16]. However, as far as we know, no previous studies exist comparing fractional RF with fractional laser for the purpose of drug delivery. Although ablation depth and width corresponded with the 1 × 9 mJ/microbeam settings of the Er:YAG laser, we observed slightly higher fluorescence intensity after Er:YAG laser irradiation at these settings than after fractional RF treatment [11, 12]. This might be due to the thick coagulation zone (relative to ablation channel depth) for the RF treatment (±50 μm) compared to that for the Er:YAG laser treatment (<± 25 μm) [11, 12]. We also noted that the RF device generated a very inhomogeneous pattern of ablation zones, where a large proportion of these zones could hardly be recognized, both before and after ICG application. The fractional lasers seemed to produce a more reproducible pattern of ablation channels. In fractional radiofrequency, thermal and biological effects may highly depend on local variations in electrical impedance due to the presence of blood vessels, hair follicles, and other adnexal structures.
When comparing the influence of ablation channel depth on ICG accumulation in the skin, we observed higher ICG fluorescence with 300 μm ablation channel depth than with 70 μm ablation channel depth. This is in accordance with other studies that suggested an ablation channel depth dependent uptake of hydrophilic substances, such as ICG. Deeper ablation channels are rapidly filled with interstitial fluid, providing a more favorable environment for hydrophilic than for hydrophobic drugs [17,18,19]. Also, deeper channels can simply contain a larger volume of the solution and have a larger contact surface with the surrounding skin, which probably enhances drug uptake.
Main limitations of this study are the ex vivo setting, the small number of skin samples, and the lack of histological controls. The skin samples all had been frozen for several days before being used for the experiments, because it was not possible to perform the experiments in freshly excised skin for logistic reasons. Surface fluorescence photography offers limited options for quantitative measurements and creates pitfalls for the interpretation of fluorescence intensity because of differences in optical properties of the structures visualized. For example, increased scattering of the light might be observed in the disintegrated tissue of the coagulation zone causing a risk for overestimation of ICG uptake. However, we were able to compare a large number of parameters in a reproducible way, while histology is sensitive to sectioning errors and unwanted alterations in tissue dimensions during fixation procedures [20, 21]. Histologic evaluation of fractional laser channels, especially when combined with fluorescence microscopy, is extremely time-consuming, thus limiting the number of parameters that can be compared or the number of skin samples that can be evaluated.
As stated in our previous study [10], only depths of up to 400 μm are investigated. Therefore, no conclusions can be drawn regarding the deposition of ICG in deeper skin layers. In addition, clinical applications for ICG are very limited. We used ICG merely as an indicator, and it might not be possible to extrapolate our findings to other drugs. Local pharmacokinetics might however be comparable to that of other hydrophilic drugs that may be used for fractional laser-assisted drug delivery, with a comparable molecular weight, including methotrexate (Log P, − 1.85; molecular weight, ±500 Da) [22, 23]. Since virtually all topical drugs that are commercially available are optimized for application on the intact skin, providing gradual release of the active substance through the stratum corneum, the development of new drug formulations exclusively for the purpose of fractional laser-assisted (or microneedling assisted) drug delivery is mandatory for the successful clinical application of this technique. In addition, physical penetration enhancement techniques, such as massage or ultrasound techniques, may be used to further enhance topical drug delivery in clinical practice [10].
In conclusion, pretreatment with fractional CO2 and Er:YAG laser enhances ICG accumulation in the skin. In our study setting, pretreatment with a fractional Er:YAG laser that stacks several pulses was more effective than pretreatment with a single pulse fractional CO2 laser, even when ablation channel depth and laser density are the same. Microneedling appeared to be a simple and effective alternative, although this might be different in vivo due to bleeding and oozing. Fractional RF did not seem effective. In line with earlier research, deeper ablation channels may be more effective for the delivery of a hydrophilic drug such as ICG. Further research is needed to correlate our findings to the histological effects of all pretreatment regimens and to reproduce our findings in vivo.
References
Haedersdal M, Sakamoto FH, Farinelli WA, Doukas AG, Tam J, Anderson RR (2010) Fractional CO(2) laser-assisted drug delivery. Lasers Surg Med 42:113–122. https://doi.org/10.1002/lsm.20860
Haedersdal M, Erlendsson AM, Paasch U, Anderson RR (2016) Translational medicine in the field of ablative fractional laser (AFXL)-assisted drug delivery: a critical review from basics to current clinical status. J Am Acad Dermatol 74:981–1004. https://doi.org/10.1016/j.jaad.2015.12.008
Hantash BM, Bedi VP, Kapadia B, Rahman Z, Jiang K, Tanner H et al (2007) In vivo histological evaluation of a novel ablative fractional resurfacing device. Lasers Surg Med 39:96–107. https://doi.org/10.1002/lsm.20468
Paasch U, Haedersdal M (2011) Laser systems for ablative fractional resurfacing. Expert Rev Med Devices 8:67–83. https://doi.org/10.1586/erd.10.74
Farkas JP, Richardson JA, Burrus CF, Hoopman JE, Brown SA, Kenkel JM (2010) In vivo histopathologic comparison of the acute injury following treatment with five fractional ablative laser devices. Aesthet Surg J 30:457–464. https://doi.org/10.1177/1090820x10373060
Banzhaf CA, Ortner VK, Philipsen PA, Haedersdal M (2019) The ablative fractional coagulation zone influences skin fluorescence intensities of topically applied test molecules-an in vitro study with fluorescence microscopy and fluorescence confocal microscopy. Lasers Surg Med 51:68–78. https://doi.org/10.1002/lsm.23034
Nguyen HX, Banga AK (2018) Delivery of methotrexate and characterization of skin treated by fabricated PLGA microneedles and fractional ablative laser. Pharm Res 35:68. https://doi.org/10.1007/s11095-018-2369-6
Park JM, Jeong KH, Bae MI, Lee SJ, Kim NI, Shin MK (2016) Fractional radiofrequency combined with sonophoresis to facilitate skin penetration of 5-aminolevulinic acid. Lasers Med Sci 31:113–118. https://doi.org/10.1007/s10103-015-1835-1
Bay C, Lerche CM, Ferrick B, Philipsen PA, Togsverd-Bo K, Haedersdal M (2017) Comparison of physical pretreatment regimens to enhance protoporphyrin IX uptake in photodynamic therapy: a randomized clinical trial. JAMA Dermatol 153:270–278. https://doi.org/10.1001/jamadermatol.2016.5268
Meesters AA, Nieboer MJ, Almasian M, Georgiou G, de Rie MA, Verdaasdonk RM et al (2019) Drug penetration enhancement techniques in ablative fractional laser assisted cutaneous delivery of indocyanine green. Lasers Surg Med. https://doi.org/10.1002/lsm.23088
Shin MK, Choi JH, Ahn SB, Lee MH (2014) Histologic comparison of microscopic treatment zones induced by fractional lasers and radiofrequency. J Cosmet Laser Ther 16:317–323. https://doi.org/10.3109/14764172.2014.957216
Taudorf EH, Haak CS, Erlendsson AM, Philipsen PA, Anderson RR, Paasch U et al (2014) Fractional ablative erbium YAG laser: histological characterization of relationships between laser settings and micropore dimensions. Lasers Surg Med 46:281–289. https://doi.org/10.1002/lsm.22228
Haak CS, Hannibal J, Paasch U, Anderson RR, Haedersdal M (2017) Laser-induced thermal coagulation enhances skin uptake of topically applied compounds. Lasers Surg Med 49:582–591. https://doi.org/10.1002/lsm.22642
van Leeuwen TG, van Erven L, Meertens JH, Motamedi M, Post MJ, Borst C (1992) Origin of arterial wall dissections induced by pulsed excimer and mid-infrared laser ablation in the pig. J Am Coll Cardiol 19:1610–1618
Lee WR, Shen SC, Sun CK, Aljuffali IA, Suen SY, Lin YK et al (2015) Fractional thermolysis by bipolar radiofrequency facilitates cutaneous delivery of peptide and siRNA with minor loss of barrier function. Pharm Res 32:1704–1713. https://doi.org/10.1007/s11095-014-1568-z
Sintov AC, Krymberk I, Daniel D, Hannan T, Sohn Z, Levin G (2003) Radiofrequency-driven skin microchanneling as a new way for electrically assisted transdermal delivery of hydrophilic drugs. J Control Release 89:311–320
Haak CS, Farinelli WA, Tam J, Doukas AG, Anderson RR, Haedersdal M (2012) Fractional laser-assisted delivery of methyl aminolevulinate: impact of laser channel depth and incubation time. Lasers Surg Med 44:787–795. https://doi.org/10.1002/lsm.22102
Erlendsson AM, Doukas AG, Farinelli WA, Bhayana B, Anderson RR, Haedersdal M (2016) Fractional laser-assisted drug delivery: active filling of laser channels with pressure and vacuum alteration. Lasers Surg Med 48:116–124. https://doi.org/10.1002/lsm.22374
Lee WR, Shen SC, Al-Suwayeh SA, Yang HH, Yuan CY, Fang JY (2011) Laser-assisted topical drug delivery by using a low-fluence fractional laser: imiquimod and macromolecules. J Control Release 153:240–248. https://doi.org/10.1016/j.jconrel.2011.03.015
Blasco-Morente G, Garrido-Colmenero C, Perez-Lopez I, Carretero-Garcia S, Martin-Castro A, Arias-Santiago S et al (2015) Study of shrinkage of cutaneous surgical specimens. J Cutan Pathol 42:253–257. https://doi.org/10.1111/cup.12401
Kerns MJ, Darst MA, Olsen TG, Fenster M, Hall P, Grevey S (2008) Shrinkage of cutaneous specimens: formalin or other factors involved? J Cutan Pathol 35:1093–1096. https://doi.org/10.1111/j.1600-0560.2007.00943.x
Taudorf EH, Lerche CM, Erlendsson AM, Philipsen PA, Hansen SH, Janfelt C et al (2016) Fractional laser-assisted drug delivery: laser channel depth influences biodistribution and skin deposition of methotrexate. Lasers Surg Med 48:519–529. https://doi.org/10.1002/lsm.22484
Taudorf EH, Lerche CM, Vissing AC, Philipsen PA, Hannibal J, D'Alvise J et al (2015) Topically applied methotrexate is rapidly delivered into skin by fractional laser ablation. Expert Opin Drug Deliv. https://doi.org/10.1517/17425247.2015.1031216
Acknowledgments
We would like to thank Dr. Florine Kingma-Vegter and Truus Venema of the Slotervaart Hospital in Amsterdam for providing the abdominoplasty skin samples. The LegatoII Pixel RF™ was provided by BlooMEDical Benelux BV, exclusively for the purpose of this study.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Nieboer, M.J., Meesters, A.A., Almasian, M. et al. Enhanced topical cutaneous delivery of indocyanine green after various pretreatment regimens: comparison of fractional CO2 laser, fractional Er:YAG laser, microneedling, and radiofrequency. Lasers Med Sci 35, 1357–1365 (2020). https://doi.org/10.1007/s10103-020-02950-2
Received:
Accepted:
Published:
Issue Date: