Abstract
Modern ultrashort pulse lasers with scanning systems provide a huge set of parameters affecting the suitability for dental applications. The present study investigates thresholds and ablation rates of oral hard tissues and restorative materials with a view towards a clinical application system. The functional system consists of a 10 W Nd:YVO4 laser emitting pulses with a duration of 8 ps at 1,064 nm. Measurements were performed on dentin, enamel, ceramic, composite, and mammoth ivory at a repetition rate of 500 kHz. By employing a scanning system, square-shaped cavities with an edge length of 1 mm were created. Ablation threshold and rate measurements were assessed by variation of the applied fluence. Examinations were carried out employing a scanning electron microscope and optical profilometer. Irradiation time was recorded by the scanner software in order to calculate the overall ablated volume per time. First high power ablation rate measurements were performed employing a laser source with up to 50 W. Threshold values in the range of 0.45 J/cm2 (composite) to 1.54 J/cm2 (enamel) were observed. Differences between any two materials are statistically significant (p < 0.05). Preparation speeds up to 37.53 mm3/min (composite) were achieved with the 10 W laser source and differed statistically significant for any two materials (p < 0.05) with the exception of dentin and mammoth ivory (p > 0.05). By employing the 50 W laser source, increased rates up to ∼50 mm3/min for dentin were obtained. The results indicate that modern USPL systems provide sufficient ablation rates to be seen as a promising technology for dental applications.
Similar content being viewed by others
References
Heisterkamp A, Mamom T, Kermani O, Drommer W, Welling H, Ertmer W, Lubatschowski H (2003) Intrastromal refractive surgery with ultrashort laser pulses: in vivo study on the rabbit eye. Graefes Arch Clin Exp Ophthalmol 241(6):511–517. doi:10.1007/s00417-003-0683-z
Ratkay-Traub I, Ferincz IE, Juhasz T, Kurtz RM, Krueger RR (2003) First clinical results with the femtosecond neodynium-glass laser in refractive surgery. J Refract Surg 19(2):94–103
Niemz MH (1994) Investigation and spectral analysis of the plasma-induced ablation mechanism of dental hydroxyapatite. Appl Phys B 58:273–281
Niemz MH (1998) Laser-tissue-interactions: fundamentals and applications. Springer-Verlag, Berlin
Niemz MH (1998) Ultrashort laser pulses in dentistry: advantages and limitations. In: Neev J, ed.: Applications of ultrashort-pulse lasers in medicine and biology. Proc SPIE 3255:84–91
Hibst R, Keller U (1989) Experimental studies of the application of the Er:YAG laser on dental hard substances: I. Measurement of the ablation rate. Lasers Surg Med 9(4):338–344
Keller U, Hibst R (1989) Experimental studies of the application of the Er:YAG laser on dental hard substances. II. Light microscopic and SEM investigations. Lasers Surg Med 9(4):345–351
Lizarelli RFZ, Kurachi C, Misoguti L, Bagnato VS (2000) A comparative study of nanosecond and picosecond laser ablation in enamel: morphological aspects. J Clin Laser Med Surg 18(3):151–157
Rode AV, Gamaly EG, Luther-Davies B, Taylor BT, Dawes J, Chan A, Lowe RM, Hannaford P (2002) Subpicosecond laser ablation of dental enamel. J Appl Phys 92:2153–2158
Hennig T, Nieswand E, Rechmann P (2001) A new picosecond laser emitting blue light for use in periodontology. In: Rechmann P, Fried D, Hennig T, eds.: Lasers in dentistry VII. Proc SPIE 4249:36–43
Serbin J, Bauer T, Fallnich C, Kasenbacher A, Arnold WH (2002) Femtosecond lasers as novel tool in dental surgery. Appl Surf Sci 197–198:737–740
Straßl M, Kopecek H, Weinrotter M, Bäcker A, Al-Janabi AH, Wieger V, Wintner E (2005) Novel applications of short and ultra-short pulses. Appl Surf Sci 247:561–570
Wieger V, Straßl M, Wintner E (2005) Pico- and microsecond laser ablation of dental restorative materials. Laser Part Beams 24:41–45. doi:10.1017/S0263034606060083
Straßl M, Yousif A, Wintner E (2007) Scanning of ultra-short laser pulses in dental applications. A comparison of scanning algorithms and pulse durations. J Oral Laser Applic 7:123–128
Wieger V, Straßl M, Wintner E (2007) Laser dental hard tissue ablation: comparison Er-lasers and scanned ultra-short pulse laser. Int J Appl Electrom 25:635–640
Bello-Silva MS, Martin Wehner M, Eduardo CP, Lampert F, Poprawe R, Hermans M, Esteves-Oliveira M (2012) Precise ablation of dental hard tissues with ultra-short pulsed lasers. Preliminary exploratory investigation on adequate laser parameters. Lasers Med Sci, online publication DOI 10.1007/s10103-012-1107-2
Locke M (2008) Structure of ivory. J Morphol 269:423–450
Niemz MH (1995) Cavity preparation with the Nd:YLF picosecond laser. J Dent Res 74(5):1194–1199
Willms L, Herschel A, Niemz MH, Pioch T (1996) Preparation of dental hard tissue with picosecond laser pulses. Lasers Med Sci 11:45–51
Neev J, Da Silva LB, Feit MD, Perry MD, Rubenchik AM, Stuart BC (1996) Ultrashort pulse lasers for hard tissue ablation. IEEE J Sel Top Quant 2(4):790–800
Lizarelli RFZ, Bagnato VS (2003) Dentistry application using a picosecond Nd:YAG laser. Laser Phys 13(5):1–5
Byskov-Nielsen J, Savolainen JM, Snogdahl Christensen M, Balling P (2010) Ultra-short pulse laser ablation of metals: threshold fluence, incubation coefficient and ablation rates. Appl Phys A 101:97–101
Schelle F, Meister J, Oehme B, Frentzen M (2012) Transmission of 1064 nm laser radiation during ablation with an ultra-short pulse laser (USPL) system. In: Rechmann P, Fried D, eds.: Lasers in dentistry XVIII. Proc SPIE 8208:82080 J-1-82080 J-8
Braun A, Krillke RF, Frentzen M, Bourauel C, Stark H, Schelle F (2013) Heat generation caused by ablation of restorative materials with an ultrashort pulse laser (USPL) system. Lasers Med Sci (in press)
Braun A, Wehry RJ, Brede O, Dehn C, Frentzen M, Schelle F (2012) Heat generation caused by ablation of restorative materials with an ultrashort pulse laser (USPL) system. Lasers Med Sci 27:297–303. doi:10.1007/s10103-010-0875-9
Feit MD, Rubenchik AM, Shore BW (1996) Unique aspects of laser energy deposition in the fs pulse regime. In: Wigdor HA, Featherstone JDB, White JM, Neev J, eds.: Lasers in dentistry II. Proc SPIE 2672: 243–249
Rode AV, Gamaly EG, Luther-Davies B, Taylor BT, Graessel M, Dawes JM, Chan A, Lowe RM, Hannaford P (2003) Precision ablation of dental enamel using a subpicosecond pulsed laser. Aust Dent J 48(4):233–239
Lizarelli RFZ, Moriyama LT, Bagnato VS (2006) Temperature response in the pulpal chamber of primary human teeth exposed to Nd:YAG laser using a picosecond pulsed regime. Photomed Laser Surg 24(5):610–615
Acknowledgements
The authors would like to thank the Federal Ministry of Education and Research Germany (Grant-No.: 13 N10190) for the financial support. Moreover, we would like to thank Univ.-Prof. Christoph Bourauel and Prof. Helmut Stark for providing the optical profilometer and scanning electron microscope, the staff at our laboratory (Silke van Dyck, Imke Beier, Beate Schiermeyer-Dunkhase) for preparing the samples as well as Dr. Bernd Oehme (Sirona Dental Systems GmbH, Germany) for the inspiring discussions.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Schelle, F., Polz, S., Haloui, H. et al. Ultrashort pulsed laser (USPL) application in dentistry: basic investigations of ablation rates and thresholds on oral hard tissue and restorative materials. Lasers Med Sci 29, 1775–1783 (2014). https://doi.org/10.1007/s10103-013-1315-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10103-013-1315-4