Abstract
The identification of bacteria directly from positive blood cultures using matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry (MALDI-TOF MS) is a new challenge to microbiologists. However, the protocols previously described are often difficult to implement in routine and comparisons are not always possible due to the variability of interpretative criteria. This study evaluated the analytical and practical performances of an in-house (IH) method, adapted from previous protocols, and the Sepsityper™ kit (Bruker Daltonics, Bremen, Germany). Positive blood cultures from 63 different patients were prospectively evaluated by both methods. To enhance the sensitivity of these methods, lowered cut-offs were assessed and validated on 66 additional samples. The IH method produced 86.4% and 73.7% correct genus and species identifications, respectively, when using the lowered cut-offs of 1.4 and 1.6 for correct genus and species identifications. The Sepsityper™ kit showed similar results (78.0% and 68.4% correct genus and species identification, respectively). However, the IH method is ten-fold less expensive than the commercial option (0.72 vs. 7.45 €/analysis) and its turnaround time is approximately 20 min versus the nearly 40 min required for the Sepsityper™ kit, which includes an extraction step. Finally, the IH method was introduced twice-daily in our routine practice.
Similar content being viewed by others
References
Seng P, Drancourt M, Gouriet F, La Scola B, Fournier PE, Rolain J-M, Raoult D (2009) Ongoing revolution in bacteriology: routine identification of bacteria by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. Clin Infect Dis 49:543–551
Bizzini A, Greub G (2010) Matrix-assisted laser desorption ionization time-of-flight mass spectrometry, a revolution in clinical microbial identification. Clin Microbiol Infect 16:1614–1619
Ferreira L, Sánchez-Juanes F, González-Avila M, Cembrero-Fuciños D, Herrero-Hernández A, González-Buitrago JM, Muñoz-Bellido JL (2010) Direct identification of urinary tract pathogens from urine samples by matrix-assisted laser desorption ionization-time of flight mass spectrometry. J Clin Microbiol 48:2110–2115
Sparbier K, Weller U, Boogen C, Kostrzewa M (2011) Rapid detection of Salmonella sp. by means of a combination of selective enrichment broth and MALDI-TOF MS. Eur J Clin Microbiol Infect Dis [Epub ahead of print]
La Scola B, Raoult D (2009) Direct identification of bacteria in positive blood culture bottles by matrix-assisted laser desorption ionisation time-of-flight mass spectrometry. PloS One 4:e8041
Kumar A, Ellis P, Arabi Y, Roberts D, Light B, Parrillo JE, Dodek P, Wood G, Kumar A, Simon D, Peters C, Ahsan M, Chateau D; Cooperative Antimicrobial Therapy of Septic Shock Database Research Group (2009) Initiation of inappropriate antimicrobial therapy results in a fivefold reduction of survival in human septic shock. Chest 136:1237–1248
Malloy PJ, Ducate MJ, Schreckenberger PC (1983) Comparison of four rapid methods for identification of Enterobacteriaceae from blood cultures. J Clin Microbiol 17:493–499
Josefson P, Strålin K, Ohlin A, Ennefors T, Dragsten B, Andersson L, Fredlund H, Mölling P, Olcén P (2011) Evaluation of a commercial multiplex PCR test (SeptiFast) in the etiological diagnosis of community-onset bloodstream infections. Eur J Clin Microbiol Infect Dis 30:1127–1134
Prod’Hom G, Bizzini A, Durussel C, Bille J, Greub G (2010) Matrix-assisted laser desorption ionization-time of flight mass spectrometry for direct bacterial identification from positive blood culture pellets. J Clin Microbiol 48:1481–1483
Ferroni A, Suarez S, Beretti J-L, Dauphin B, Bille E, Meyer J, Bougnoux M-E, Alanio A, Berche P, Nassif X (2010) Real-time identification of bacteria and Candida species in positive blood culture broths by matrix-assisted laser desorption ionization-time of flight mass spectrometry. J Clin Microbiol 48:1542–1548
Stevenson LG, Drake SK, Murray PR (2010) Rapid identification of bacteria in positive blood culture broths by matrix-assisted laser desorption ionization-time of flight mass spectrometry. J Clin Microbiol 48:444–447
Christner M, Rohde H, Wolters M, Sobottka I, Wegscheider K, Aepfelbacher M (2010) Rapid identification of bacteria from positive blood culture bottles by use of matrix-assisted laser desorption-ionization time of flight mass spectrometry fingerprinting. J Clin Microbiol 48:1584–1591
Moussaoui W, Jaulhac B, Hoffmann A-M, Ludes B, Kostrzewa M, Riegel P, Prévost G (2010) Matrix-assisted laser desorption ionization time-of-flight mass spectrometry identifies 90% of bacteria directly from blood culture vials. Clin Microbiol Infect 16:1631–1638
Schmidt V, Jarosch A, März P, Sander C, Vacata V, Kalka-Moll W (2011) Rapid identification of bacteria in positive blood culture by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. Eur J Clin Microbiol Infect Dis [Epub ahead of print]
Ferreira L, Sánchez-Juanes F, Porras-Guerra I, García-García MI, García-Sánchez JE, González-Buitrago J-M, Muñoz-Bellido J-L (2011) Microorganisms direct identification from blood culture by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Clin Microbiol Infect 17:546–551
Ferreira L, Sánchez-Juanes F, Muñoz-Bellido J-L, González-Buitrago J-M (2011) Rapid method for direct identification of bacteria in urine and blood culture samples by matrix-assisted laser desorption ionization time-of-flight mass spectrometry: intact cell vs. extraction method. Clin Microbiol Infect 17:1007–1012
Kok J, Thomas LC, Olma T, Chen SCA, Iredell JR (2011) Identification of bacteria in blood culture broths using matrix-assisted laser desorption-ionization Sepsityper™ and time of flight mass spectrometry. PLoS One 6(8):e23285
Croxatto A, Prod’Hom G, Greub G (2011) Applications of MALDI-TOF mass spectrometry in clinical diagnostic microbiology. FEMS Microbiol Rev [Epub ahead of print]
Peleg AY, Hooper DC (2010) Hospital-acquired infections due to gram-negative bacteria. N Engl J Med 362:1804–1813
Neville SA, Lecordier A, Ziochos H, Chater MJ, Gosbell IB, Maley MW, Van Hal SJ (2011) Utility of matrix-assisted laser desorption ionization-time of flight mass spectrometry following introduction for routine laboratory bacterial identification. J Clin Microbiol 49:2980–2984
Justesen US, Holm A, Knudsen E, Andersen LB, Jensen TG, Kemp M, Skov MN, Gahrn-Hansen B, Møller JK (2011) Species identification of clinical isolates of anaerobic bacteria: a comparison of two matrix-assisted laser desorption ionization-time of flight mass spectrometry systems. J Clin Microbiol 49:4314–4318
De Bel A, Wybo I, Piérard D, Lauwers S (2010) Correct implementation of matrix-assisted laser desorption ionization-time of flight mass spectrometry in routine clinical microbiology. J Clin Microbiol 48:991
Yan Y, He Y, Maier T, Quinn C, Shi G, Li H, Stratton CW, Kostrzewa M, Tang Y-W (2011) Improved identification of yeast species directly from positive blood culture media by combining Sepsityper specimen processing and Microflex analysis with the matrix-assisted laser desorption ionization Biotyper system. J Clin Microbiol 49:2528–2532
Trenholme GM, Kaplan RL, Karakusis PH, Stine T, Fuhrer J, Landau W, Levin S (1989) Clinical impact of rapid identification and susceptibility testing of bacterial blood culture isolates. J Clin Microbiol 27:1342–1345
Emonet S, Schrenzel J (2011) How could rapid bacterial identification improve the management of septic patients? Expert Rev Anti Infect Ther 9:707–709
Seifert H (2009) The clinical importance of microbiological findings in the diagnosis and management of bloodstream infections. Clin Infect Dis 48:S238–S245
Acknowledgements
We thank Michèle Dramaix from the School of Public Health, Université Libre de Bruxelles, for her help in the statistical analysis process. The technical assistance provided by David Fage was also greatly appreciated.
This work has been partially presented at the 51st Interscience Conference on Antimicrobial Agents and Chemotherapy (ICAAC), Chicago, IL, USA, September 2011 (Poster D1292).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Martiny, D., Dediste, A. & Vandenberg, O. Comparison of an in-house method and the commercial Sepsityper™ kit for bacterial identification directly from positive blood culture broths by matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry. Eur J Clin Microbiol Infect Dis 31, 2269–2281 (2012). https://doi.org/10.1007/s10096-012-1566-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10096-012-1566-1