Abstract
Bordetella pertussis-specific antibodies can be detected by enzyme-linked immunosorbent assays (ELISAs) or multiplex immunoassays. Assays use purified or mixed antigens, and only pertussis toxin (PT) is specific for B. pertussis. The interpretation of results can be based on dual-sample or single-sample serology using one or two cut-offs. The EU Pertstrain group recommends that: (i) ELISAs and multiplex immunoassays should use purified non-detoxified PT as an antigen, that they should have a broad linear range and that they should express results quantitatively in International Units per millilitre (IU/ml); (ii) a single or dual diagnostic cut-off for single-serum serology using IgG-anti-PT between 50 and 120 IU/ml should be used, and diagnostic serology cannot be validly interpreted for one year after vaccination with acellular pertussis (aP) vaccines; (iii) IgA-anti-PT should only be used with indeterminate IgG-anti-PT levels or when a second sample cannot be obtained. This group discourages using: (i) other antigens in routine diagnostics, as they are not specific; (ii) micro-agglutination, due to its lack of sensitivity; (iii) immunoblots for pertussis serodiagnosis, as results cannot be quantified; (iv) other methods, such as complement fixation or indirect immunofluorescence, due to their low sensitivity and/or specificity.
Similar content being viewed by others
Indications for pertussis diagnostics
The diagnosis of pertussis should only be attempted in patients with symptoms compatible with pertussis, such as prolonged coughing with paroxysms and/or whooping or choking. In infants, older vaccinated children, adolescents and adults, the clinical course may not be typical, and prolonged coughing may be the only symptom. In these cases, the diagnosis of pertussis requires laboratory methods for confirmation.
Direct and indirect tests are available. Direct tests are real-time polymerase chain reaction (PCR) and culture, whereas indirect tests measure specific antibodies in oral fluid or sera. Here, we focus on the detection of antibodies against Bordetella pertussis antigens.
Development of the recommendations
The EU Pertstrain group consists of representatives of the Bordetella reference laboratories in their respective EU countries. In a face-to-face meeting at the Istituto Superiore di Sanità (ISS), Rome, Italy, in 2009, the outline of a manuscript was discussed and agreed upon. After a search of relevant databases, a first draft was written (NG) and intensively reviewed by members of the group. In a second face-to-face meeting, at the Rijksinstituut voor Volksgezondheid en Milieu (RIVM), Bilthoven, the Netherlands, in June 2010, the draft recommendations were broadly discussed and agreed upon. A second version of the recommendations was drafted (NG, CHWvK). This version was then reviewed again by all authors.
Serological tests
Blood/serum
Most serological assays are validated to test serum; some may also be validated to test heparinised plasma or ethylenediaminetetraacetic acid (EDTA) plasma. Capillary blood samples may be used if a sufficient volume cannot be obtained otherwise. Serum or plasma must be separated as soon as possible after blood sampling (24 h at room temperature). If acute and convalescent serum samples taken at least three weeks apart from one individual are available, they should be tested together in one run. All serum samples may be frozen (at −20°C) after the primary assay and re-analysed later together with a possible second sample.
ELISA in serum samples
In preparation for the acellular vaccine studies in the 1990s, the enzyme-linked immunosorbent assay (ELISA) methodology, the type of antigens, as well as the reference sera have been standardised, and they have been used in all acellular vaccine trials, in sero-epidemiological studies in many countries and for diagnostic purposes in various laboratories [1–5].
Antigens
ELISA is normally done with highly purified antigens. The antigens most frequently used are pertussis toxin (PT) and filamentous haemagglutinin (FHA), and to a lesser extent, pertactin (PRN) and fimbriae (FIM). Sometimes, adenylate cyclase-haemolysin toxin (ACT) is also used. These antigens are used in their active, i.e. non-detoxified, form. The storage conditions of the antigens as well as the duration of storage can vary significantly according to the manufacturers who provide the purified antigens. Anti-PT antibodies are specific for B. pertussis, whereas anti-FHA, anti-PRN, anti-FIM and anti-ACT are less specific due to cross-reactivity with other microbial antigens (e.g. other Bordetella species, Haemophilus species, Mycoplasma pneumoniae, Escherichia coli). For this reason, in routine diagnosis, only the measurement of anti-PT antibodies is recommended. However, the measurement of other antibodies may be used for transmission, immunogenicity or vaccine non-inferiority studies. Some ELISAs, especially commercial kits, use a mixture of antigens or supernatants or sonicates of whole B. pertussis cells. The use of kits with mixed antigens is not recommended [6].
Reference sera
World Health Organization (WHO) references are available from the National Institute for Biological Standards and Control (NIBSC, Potters Bar, UK) (“WHO International Standard (06/140)” and “WHO Reference Reagent (06/142)”) for the measurement of human antibodies to B. pertussis antigens, and, thus, quantitative results should be reported in IU/ml [7].
Plates
For in-house ELISAs, differences between plates were observed, and Thermo Scientific Nunc MaxiSorp (Nunc AS, Copenhagen, Denmark) plates and Greiner MICROLON High Binding (Greiner Bio-One, Frickenhausen, Germany) plates seemed to work better than others [8].
Flow cytometry
Bead-based multiplex assays that simultaneously measure antibodies to various antigens have also been applied to B. pertussis antigens. The assays use fluorescent microparticles to which purified antigens are covalently coupled and are based on a proprietary method patented in 1983 in Germany [9] or on xMAP Technology from Luminex™ [10]. These assays seem to produce results comparable to conventional ELISA systems.
Immunoblots, line and dot blots
Many commercial kits detect anti-B. pertussis and/or anti-PT, anti-FHA, anti-PRN and also ACT antibodies in serums using blotting techniques. Kits using whole-cell suspensions as antigens are not specific for the detection/diagnosis of pertussis infections due to the great cross-reactivity with other bacteria (e.g. other Bordetella species, Haemophilus species, Mycoplasma pneumoniae). Antigens used in these kits have to be validated concerning their purity, as contamination with other antigens or antigen aggregates can also produce false-positive results. A quantitative interpretation of blot results is not possible, but a semi-quantitative reporting may be possible. Although various CE-marked commercial kits are available, a recent comparison showed significant differences between kits and an insufficient correlation to the values of the 1st International Reference Preparation (Kennerkuecht et al. submitted). Consequently, the use of immunoblots for pertussis serology is not recommended by the EU Pertstrain group.
Micro-agglutination
Micro-agglutination has been widely used before ELISA systems became available [11]. As with other bacterial agglutination assays, micro-agglutination with B. pertussis cells mainly measures IgM antibodies to outer surface antigens such as FIM, PRN and lipooligosaccharide (LOS). Results are reported in titres starting at 1:20 or 1:40. No agglutinin titre has been attributed to the WHO reference preparation so far. Agglutinating antibodies can be used to measure the exposure of a population to B. pertussis antigens; on an individual level, the micro-agglutination method is not useful for confirming the clinical diagnosis of pertussis.
CHO cell neutralisation
This test used the ability of PT to induce characteristic morphological changes in a culture of Chinese hamster ovary (CHO) cells. These changes can be neutralised by the presence of anti-PT antibodies. The titres of CHO cell-neutralising antibodies correlate well with the IgG-anti-PT ELISA values, and, thus, CHO cell assays are rarely used for diagnostic purposes [8, 12]. The interpretation of CHO assays cannot be standardised, and it is difficult to interpret the morphological changes and to score the results objectively.
Complement fixation
Complement fixation using whole cells of B. pertussis has been rarely used and suffers from a lack of sensitivity and specificity.
Indirect immunofluorescence
Indirect immunofluorescence using whole cells of B. pertussis has the same disadvantages as complement fixation
Oral fluid
Oral fluid can be sampled by standardised means, e.g. Oracol swabs (Malvern Medical Developments) or OraSure oral specimen collection devices (OraSure Technologies Inc.). The diagnostic sensitivity of measuring antibodies in oral fluid samples is lower (∼80%) as compared to serum samples, but the samples can easily be obtained and offer an adjunct to diagnostic serology
ELISA in oral fluid
An IgG-capture ELISA capable of detecting anti-PT IgG in oral fluid has been developed. The assay was evaluated by comparison to a serum ELISA. The results showed that the oral fluid assay detected seropositive subjects with a sensitivity of 79.7% [95% confidence interval (CI) 68.3–88.4] and a specificity of 96.6% (95% CI 91.5–99.1) relative to the ELISA [13]. This assay has since been modified to include a monoclonal capture antibody; however, no commercial assays for measuring antibodies in oral fluid are available.
Reporting of serological results using ELISA or flow cytometry
Concentrations of antibodies to B. pertussis antigens should be quantitatively expressed in IU/ml as reference preparations are available [7]. The reference preparation defines values for antibodies of isotypes IgG and IgA to PT, FHA, PRN and to FIM. Assigned values of the reference preparation are described in Table 1. The numerical values of IU/ml are equivalent to the previously used ELISA units/ml (EU/ml) derived from the human reference preparations lot 3, lot 4 and lot 5 from the Center for Biologics Evaluation and Research/Food and Drug Administration (CBER/FDA), Bethesda, MD, USA.
Interpretation of serological results
PT and FHA are contained in substantial amounts in all acellular vaccines licensed in Europe (except in Denmark), and PRN and FIM are also components of licensed acellular pertussis vaccines. Thus, the immune response against infection or vaccination cannot be distinguished and pertussis vaccination may interfere with the interpretation of serological results. Due to a continuous circulation of Bordetellae in the population, IgG-anti-PT and other antibodies to Bordetella antigens are detectable in the majority of all adolescent and adult populations tested so far [14]. Thus, serological diagnosis of pertussis must be performed in immunological non-naïve populations with different kinetics of antibody production.
Additionally, pertussis serology suffers from various other drawbacks:
-
Commercial ELISAs are of different antigen composition and quality
-
Reference antigens with good purity are not easily available
-
Population-based cut-offs for single-sample serology may need verification after changes in the vaccination schedule
-
Interpretation of anti-PT concentrations in recently vaccinated persons is difficult
Dual-sample serology based on ≥100% increase in antibody concentration or on ≥50% decrease in antibody concentration is a sensitive and specific method for serological diagnosis [1, 4]. However, even in paired sera, no antibody increase may be seen after infection due to the secondary immune response, and the diagnosis may also be based on a decrease of antibodies, which may be too slow to reach 50% between the acute and convalescent sample.
In clinical practice, diagnosis is mostly based on single-sample serology using a single or a more continuous cut-off. For single-sample serology, various cut-off values for IgG-anti-PT have been proposed (Table 2). In Massachusetts, 100 EU/ml was used, and, later, in order to increase specificity, >∼200 EU/ml IgG-anti-PT (>20 μg/ml) was employed. In the Netherlands, a cut-off >∼125 EU/ml IgG-anti-PT with higher specificity or 62 EU/ml with slightly lower specificity has been used [15, 16]. In Germany, a cut-off of ∼40 EU/ml IgG-anti-PT was suggested, together with ∼50 EU/ml IgA-anti-FHA. A sero-epidemiological survey was recently performed in various countries in Western Europe using a cut-off of 125 EU/ml for recent infection, and it can be used as a population-based reference [14]. Another recently completed sero-surveillance in US sera found that three populations could be separated according to their levels of IgG-anti-PT: one cut-off was estimated at 94 EU/ml and a lower cut-off was estimated at 48 EU/ml [17]. Using the lower 50 EU/ml cut-off may be especially useful in outbreak situations, and, overall, this cut-off of 50 EU/ml seems to be more appropriate for diagnosis rather than a higher cut-off with lower sensitivity [18].
Overall, it is astonishing that, irrespective of various vaccination strategies, cut-offs for single-sample serology are comparable throughout the countries in which they were evaluated.
A comparison of receiver operating characteristic (ROC) curve analyses with data from Denmark, the Netherlands and the UK showed that, for all three countries, the single cut-off with optimal sensitivity and specificity may be in the range between 60 and 75 IU/ml.
It may be sensible to use a dual cut-off between 62 and 125 IU/ml according to countries as a proof of a recent infection with B. pertussis, provided that the patient was not vaccinated during the last 12 months (Table 2). If diagnosis cannot be established with certainty from a single serum, but is deemed to be necessary according to the clinical symptoms, antibodies should be measured in a second (convalescent) serum sample at two to four weeks interval. In case of non-availability of a second serum sample, measurement of IgA anti-PT antibodies can be an alternative, but no broadly accepted cut-off is available for this antibody subclass. Considering its relatively high specificity and low sensitivity, a cut-off near the minimal level of quantification, which may be between 10 and 20 IU/ml, may seem reasonable [19].
Recommendations for serological testing with suspected pertussis
In neonates and young infants, PCR and/or culture should be performed on nasopharyngeal samples, nasopharyngeal swabs (NPSs) or nasopharyngeal aspirates (NPAs) as soon as possible post-onset of symptoms. The measurement of IgG-anti-PT is only meaningful for older children/adults, including parents and other household members. In vaccinated children, adolescents and adults with less than two weeks of coughing culture and PCR from nasopharyngeal samples should be done. For adolescents and adults with coughing of less than three weeks, PCR and the measurement of IgG-anti-PT should be performed [1]. If coughing lasted at least 2 to 3 weeks, the measurement of IgG-anti-PT should be sufficient. In outbreak situations, PCR and culture should be performed from nasopharyngeal samples and IgG-anti-PT should be measured in serum samples.
References
André P, Caro V, Njamkepo E, Wendelboe AM, Van Rie A, Guiso N (2008) Comparison of serological and real-time PCR assays to diagnose Bordetella pertussis infection in 2007. J Clin Microbiol 46(5):1672–1677
Guiso N (2007) Laboratory manual for the diagnosis of whooping cough caused by Bordetella pertussis/Bordetella parapertussis. World Health Organization (WHO). Available online at: http://www.who.int/vaccines-documents/DocsPDF04/www788.pdf
Meade BD, Deforest A, Edwards KM, Romani TA, Lynn F, O’Brien CH, Swartz CB, Reed GF, Deloria MA (1995) Description and evaluation of serologic assays used in a multicenter trial of acellular pertussis vaccines. Pediatrics 96(3 Pt 2):570–575; Erratum in Pediatrics 1995 Dec;96(6):following 1199
Simondon F, Iteman I, Preziosi MP, Yam A, Guiso N (1998) Evaluation of an immunoglobulin G enzyme-linked immunosorbent assay for pertussis toxin and filamentous hemagglutinin in diagnosis of pertussis in Senegal. Clin Diagn Lab Immunol 5(2):130–134
Tondella ML, Carlone GM, Messonnier N, Quinn CP, Meade BD, Burns DL, Cherry JD, Guiso N, Hewlett EL, Edwards KM, Xing D, Giammanco A, Wirsing von König CH, Han L, Hueston L, Robbins JB, Powell M, Mink CM, Poolman JT, Hildreth SW, Lynn F, Morris A (2009) International Bordetella pertussis assay standardization and harmonization meeting report. Centers for Disease Control and Prevention, Atlanta, Georgia, United States, 19–20 July 2007. Vaccine 27(6):803-814
Riffelmann M, Thiel K, Schmetz J, Wirsing von Koenig CH (2010) Performace of commercial enzyme-linked immunosorbent assays for the detection of antibodies to Bordetella pertussis. J Clin Microbiol, Oct. 13
Xing D, Wirsing von König CH, Newland P, Riffelmann M, Meade BD, Corbel M, Gaines-Das R (2009) Characterization of reference materials for human antiserum to pertussis antigens by an international collaborative study. Clin Vaccine Immunol 16(3):303–311
Dalby T, Sorensen C, Pedersen JW, Krogfelt KA (2010) Pertussis serology: assessment of a quantitative IgG-anti-PT ELISA for replacement of the CHO cell assay. APMIS (in press)
Reder S, Riffelmann M, Becker C, Wirsing von König CH (2008) Measuring immunoglobulin G antibodies to tetanus toxin, diphtheria toxin, and pertussis toxin with single-antigen enzyme-linked immunosorbent assays and a bead-based multiplex assay. Clin Vaccine Immunol 15(5):744–749
van Gageldonk PGM, van Schaijk FG, van der Klis FR, Berbers GAM (2008) Development and validation of a multiplex immunoassay for the simultaneous determination of serum antibodies to Bordetella pertussis, diphtheria and tetanus. J Immunol Methods 335(1–2):79–89
Blumberg DA, Pineda E, Cherry JD, Caruso A, Scott JV (1992) The agglutinin response to whole-cell and acellular pertussis vaccines is Bordetella pertussis-strain dependent. Am J Dis Child 146(10):1148–1150
Granström G, Wretlind B, Salenstedt C-R, Granström M (1988) Evaluation of serologic assays for diagnosis of whooping cough. J Clin Microbiol 26(9):1818–1823
Litt DJ, Samuel D, Duncan J, Harnden A, George RC, Harrison TG (2006) Detection of anti-pertussis toxin IgG in oral fluids for use in diagnosis and surveillance of Bordetella pertussis infection in children and young adults. J Med Microbiol 55(Pt 9):1223–1228
Pebody RG, Gay NJ, Giammanco A, Baron S, Schellekens J, Tischer A, Olander RM, Andrews NJ, Edmunds WJ, Lecoeur H, Lévy-Bruhl D, Maple PA, de Melker H, Nardone A, Rota MC, Salmaso S, Conyn-van Spaendonck MA, Swidsinski S, Miller E (2005) The seroepidemiology of Bordetella pertussis infection in Western Europe. Epidemiol Infect 133(1):159–171
de Melker HE, Versteegh FGA, Conyn-van Spaendonck MAE, Elvers LH, Berbers GAM, van der Zee A, Schellekens JFP (2000) Specificity and sensitivity of high levels of immunoglobulin G antibodies against pertussis toxin in a single serum sample for diagnosis of infection with Bordetella pertussis. J Clin Microbiol 38(2):800–806
Versteegh FG, Mertens PL, de Melker HE, Roord JJ, Schellekens JF, Teunis PF (2005) Age-specific long-term course of IgG antibodies to pertussis toxin after symptomatic infection with Bordetella pertussis. Epidemiol Infect 133(4):737–748
Baughman AL, Bisgard KM, Edwards KM, Guris D, Decker MD, Holland K, Meade BD, Lynn F (2004) Establishment of diagnostic cutoff points for levels of serum antibodies to pertussis toxin, filamentous hemagglutinin, and fimbriae in adolescents and adults in the United States. Clin Diagn Lab Immunol 11(6):1045–1053
Horby P, Macintyre CR, McIntyre PB, Gilbert GL, Staff M, Hanlon M, Heron LG, Cagney M, Bennett C (2005) A boarding school outbreak of pertussis in adolescents: value of laboratory diagnostic methods. Epidemiol Infect 133(2):229–236
Ward JI, Cherry JD, Chang SJ, Partridge S, Keitel W, Edwards K, Lee M, Treanor J, Greenberg DP, Barenkamp S, Bernstein DI, Edelman R; APERT Study Group (2006) Bordetella pertussis infections in vaccinated and unvaccinated adolescents and adults, as assessed in a national prospective randomized Acellular Pertussis Vaccine Trial (APERT). Clin Infect Dis 43(2):151–157, Epub 2006 Jun 5
Marchant CD, Loughlin AM, Lett SM, Todd CW, Wetterlow LH, Bicchieri R, Higham S, Etkind P, Silva E, Siber GR (1994) Pertussis in Massachusetts, 1981–1991: Incidence, serologic diagnosis, and vaccine effectiveness. J Infect Dis 169(6):1297–1305
Yih WK, Lett SM, des Vignes FN, Garrison KM, Sipe PL, Marchant CD (2000) The increasing incidence of pertussis in Massachusetts adolescents and adults, 1989–1998. J Infect Dis 182(5):1409–1416
Wirsing von König CH, Gounis D, Laukamp S, Bogaerts H, Schmitt HJ (1999) Evaluation of a single-sample serological technique for diagnosing pertussis in unvaccinated children. Eur J Clin Microbiol Infect Dis 18(5):341–345
Open Access
This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
Author information
Authors and Affiliations
Consortia
Corresponding author
Additional information
Members of the EU Pertstrain group are listed in the appendix.
Appendix
Appendix
Table 3 shows the members of the EU Pertstrain group.
Rights and permissions
Open Access This is an open access article distributed under the terms of the Creative Commons Attribution Noncommercial License (https://creativecommons.org/licenses/by-nc/2.0), which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
About this article
Cite this article
Guiso, N., Berbers, G., Fry, N.K. et al. What to do and what not to do in serological diagnosis of pertussis: recommendations from EU reference laboratories. Eur J Clin Microbiol Infect Dis 30, 307–312 (2011). https://doi.org/10.1007/s10096-010-1104-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10096-010-1104-y