Abstract
The aim of this study was to evaluate real-time PCR (LightCycler) kits for the detection of methicillin-resistant Staphylococcus aureus in enrichment broth using 200 sets of patient screening swab samples. One hundred sets were processed using a lysostaphin/lysozyme extraction method and a further 100 were tested using a column extraction kit. The PCR kits with lysostaphin/lysozyme lysis showed 95.7% sensitivity, 90.8% specificity, and negative and positive predictive values of 98.6% and 75.9%, respectively, compared with 88%, 95.9%, 84.6% and 95.9%, respectively, with the column extraction kit.
Similar content being viewed by others
References
Diekema DJ, Pfaller MA, Schmitz FJ, Smayevsky J, Bell J, Jones RN, Beach M and the SENTRY participants group (2001) Survey of infections due to Staphylococcus species: frequency of occurrence and antimicrobial susceptibility of isolates collected in the United States, Canada, Latin America, Europe, and the Western Pacific Region for the SENTRY Antimicrobial Surveillance Program 1997–1999. Clin Infect Dis 32 (Suppl 2):114–132
Brown DFJ (2001) Detection of methicillin/oxacillin resistance in staphylococci. J Antimicrobial Chemother 48 (Suppl 1):65–70
Cookson B (1997) Is it time to stop searching for MRSA? Screening is still important. Br Med J 314:664–665
Grisold AJ, Leitner E, Muhlbauer G, Marth E, Kessler HH (2002) Detection of methicillin-resistant Staphylococcus aureus and simultaneous confirmation by automated nucleic acid extraction and real-time PCR. J Clin Microbiol 40:2392–2397
Rohrer S, Tschierske M, Zbinden R, Berger-Bachi B (2001) Improved methods for detection of methicillin-resistant Staphylococcus aureus. Eur J Clin Microbiol Infect Dis 20:267–270
Shrestha NK, Shermock KM, Gordon SM, Tuohy MJ, Wilson DA, Cwynar RE, Banbury MK, Longworth DL, Isada CM, Mawhorter SD, Procop GW (2003) Predictive value and cost-effectiveness analysis of a rapid polymerase chain reaction for preoperative detection of nasal carriage of Staphylococcus aureus. Infect Control Hosp Epidemiol 25:327–333
Fang H, Hedin G (2003) Rapid screening and identification of methicillin-resistant Staphylococcus aureus from clinical samples by selective-broth and real-time PCR assay. J Clin Microbiol 41:2894–2899
Jonas D, Speck M, Daschner FD, Grundmann H (2002) Rapid PCR-based identification of methicillin-resistant Staphylococcus aureus from screening swabs. J Clin Microbiol 40:1821–1823
Towner KJ, Talbot DCS, Curran R, Webster CA, Humphreys H (1998) Development and evaluation of a PCR-based immunoassay for the rapid detection of methicillin-resistant Staphylococcus aureus. J Med Microbiol 47:607–613
Francois P, Pittet D, Bento M, Pepey B, Vaudaux P, Lew D, Schrenzel J (2003) Rapid detection of methicillin-resistant Staphylococcus aureus directly from sterile or nonsterile clinical samples by a new molecular assay. J Clin Microbiol 41:254–260
Huletsky A, Giroux R, Rossbach V, Gagnon M, Vaillancourt M, Bernier M, Gagnon F, Truchon K, Bastien M, Picard FJ, van Belkum A, Ouellette M, Roy PH, Bergeron MG (2004) New real-time PCR assay for rapid detection of methicillin-resistant Staphylococcus aureus directly from specimens containing a mixture of staphylococci. J Clin Microbiol 42:1875–1884
Levi K, Bailey C, Bennett A, Marsh P, Cardy DLN, Towner KJ (2003) Evaluation of an isothermal signal amplification method for rapid detection of methicillin-resistant Staphylococcus aureus from patient-screening swabs. J Clin Microbiol 41:3187–3191
El-Zimaity D, Dawson SJ, Barrett S, Moseley E (2004) Preoperative screening of elective orthopaedic patients for MRSA. J Hosp Infect 56:164–167
Farr BM, Jarvis WR (2002) Would active surveillance cultures help control healthcare-related methicillin-resistant Staphylococcus aureus infections? Infect Control Hosp Epidemiol 23:65–68
Karchmer TB, Durbin LJ, Simonton BM, Farr BM (2002) Cost-effectiveness of active surveillance cultures and contact/droplet precautions for control of methicillin-resistant Staphylococcus aureus. J Hosp Infect 51:126–132
Acknowledgements
We are indebted to the staff at the Department of Microbiology at University Hospital, Nottingham, UK, for their collaboration in providing screening swabs and to Roche Diagnostics for providing the LightCycler kits
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Levi, K., Towner, K.J. Rapid detection of methicillin-resistant Staphylococcus aureus from screening enrichment broths by real-time PCR. Eur J Clin Microbiol Infect Dis 24, 423–427 (2005). https://doi.org/10.1007/s10096-005-1336-4