Skip to main content

Advertisement

Log in

Transformation of vibration signals in rotary blood pumps: the diagnostic potential of pump failure

  • Brief Communication
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

Although non-destructive and continuous monitoring is indispensable for long-term circulatory support with rotary blood pumps, a practical monitoring system has not yet been developed. The objective of this study was to investigate the possibility of detecting pump failure caused by thrombus formation through the monitoring of vibration signals. The data acquisition equipment included vibration pickups, a charge amplifier, vibration analysis systems, and exclusive hardware. A pivot-bearing centrifugal pump with a mock circuit was investigated for vibration analysis. To simulate the four common areas of thrombus formation, we used a piece of silicon attached to each of the following four locations: the total area of the bottom of the impeller, an eccentric shape on the bottom of the impeller, a circular shape around the shaft top, and an eccentric shape on the top of the impeller. Vibration signals were picked up, and the power spectrum density analysis was performed at pump rotational speeds of 2100, 2400, and 3000 rpm. In this study, pump failure could be detected, and the types of imitation thrombi could be determined. We conclude that vibration detection with a computerized analysis system is a potentially valuable diagnostic tool for long-term circulatory support with rotary blood pumps.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. Kyo S, Minami T, Nishimura T, Gojo S, Ono M. New era for therapeutic strategy for heart failure: destination therapy by left ventricular assist device. J Cardiol. 2012;59:101–9.

    Article  PubMed  Google Scholar 

  2. Collacott RA. Vibration monitoring and diagnosis. New York: Halsted Press; 1979.

    Google Scholar 

  3. Rao JS. Advanced theory of vibration. New York: John Wiley and Sons; 1979.

    Google Scholar 

  4. Nakazawa T, Tayama E, Takami Y, Glueck J, Nosé Y. In vitro thrombogenesis study in the Gyro C1E3 for vibration assessment. Artif Organs. 1997;21:714–9.

    Article  PubMed  CAS  Google Scholar 

  5. Nakazawa T, Makinouchi K, Takami Y, Glueck J, Tayama E, Nosé Y. Vibration assessment for thrombus formation in the centrifugal pump. Artif Organs. 1997;21:318–22.

    Article  PubMed  CAS  Google Scholar 

  6. Roberts SG, Hutchinson TM, Arnaud SB, Kiratli BJ, Martin RB, Steele CR. Noninvasive determination of bone mechanical properties using vibration response: a refined model and validation in vivo. J Biomech. 1996;29:91–8.

    Article  PubMed  CAS  Google Scholar 

  7. Huang HM, Chiu CL, Yeh CY, Lee SY. Factors influencing the resonance frequency of dental implants. J Oral Maxillofac Surg. 2003;61:1184–8.

    Article  PubMed  Google Scholar 

  8. Shao F, Xu W, Crocombe A, Ewins D. Natural frequency analysis of osseointegration for trans-femoral implant. Ann Biomed Eng. 2007;35:817–24.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Koji Kawahito.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kawahito, K. Transformation of vibration signals in rotary blood pumps: the diagnostic potential of pump failure. J Artif Organs 16, 393–396 (2013). https://doi.org/10.1007/s10047-013-0709-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-013-0709-1

Keywords

Navigation