Dysfunction of an ATS valve in the aortic position: the first reported case caused by pannus formation

  • CASE REPORT
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

A 64-year-old woman underwent aortic valve replacement with a 21-mm Advancing The Standard (ATS) open-pivot mechanical heart valve for bicuspid aortic valve stenosis. In addition to the appearance of a new cardiac murmur, echocardiography performed 3 years after surgery showed a high pressure gradient across the ATS valve and a reduction in the valve orifice area. Cineradiography of the valve revealed restricted leaflet opening. Subsequent multidetector-row computed tomography clearly demonstrated pannus overgrowth on the inflow aspect of the ATS valve. During a repeat operation, subvalvular overgrown pannus was confirmed and the ATS valve was replaced with a bioprosthetic valve. This is the first reported case of prosthetic valve dysfunction resulting from pannus formation in a patient with an ATS valve in the aortic position.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. N Vitale A Renzulli L Agozzino A Pollice N Tedesco LDLT Schinosa M Cotrufo (1997) ArticleTitleObstruction of mechanical mitral prostheses: analysis of pathological findings Ann Thorac Surg 63 1101–1106 Occurrence Handle9124913 Occurrence Handle1:STN:280:ByiB2cfjt1M%3D

    PubMed  CAS  Google Scholar 

  2. H Teshima N Hayashida H Yano M Nishimi E Tayama S Fukunaga H Akashi T Kawara S Aoyagi (2003) ArticleTitleObstruction of St. Jude Medical valves in the aortic position: histology and immunohistochemistry of pannus J Thorac Cardiovasc Surg 126 401–407 Occurrence Handle10.1016/S0022-5223(03)00702-5 Occurrence Handle12928636

    Article  PubMed  Google Scholar 

  3. S Aoyagi Y Nishimi H Kawano E Tayama S Fukunaga N Hayashida H Akashi T Kawara (2000) ArticleTitleObstruction of St. Jude Medical valves in the aortic position: significance of a combination of cineradiography and echocardiography J Thorac Cardiovasc Surg 120 142–147 Occurrence Handle10.1067/mtc.2000.106524 Occurrence Handle10884667 Occurrence Handle1:STN:280:DC%2BD3czovVWisA%3D%3D

    Article  PubMed  CAS  Google Scholar 

  4. S Aoyagi T Kawara S Fukunaga T Mizoguchi Y Nishi H Kawano K Arinaga (1997) ArticleTitleCineradiographic evaluation of ATS open pivot bileaflet valve J Heart Valve Dis 6 258–263 Occurrence Handle9183724 Occurrence Handle1:STN:280:ByiA38nptFU%3D

    PubMed  CAS  Google Scholar 

  5. DJ Radford PG Pohlner (2002) ArticleTitleFormation of pannus on prosthetic valves in a child with pseudoxanthoma elasticum Cardiol Young 12 183–185 Occurrence Handle12018727

    PubMed  Google Scholar 

  6. H Teshima N Hayashida S Fukunaga E Tayama T Kawara S Aoyagi M Uchida (2004) ArticleTitleUsefulness of multidetector-row computed tomography scanner for detecting pannus formation Ann Thorac Surg 77 523–526 Occurrence Handle10.1016/S0003-4975(03)01531-5 Occurrence Handle14759431

    Article  PubMed  Google Scholar 

  7. RW Emery CC Krogh DJ Jones DM Nicoloff DP Blake KV Arom (2004) ArticleTitleFive-year follow up of the ATS mechanical heart valve J Heart Valve Dis 13 231–238 Occurrence Handle15086262

    PubMed  Google Scholar 

  8. GJ Van Nooten Y Van Belleghem F Caes K Francois H Van Overbeke T Bove Y Taeymans (2003) ArticleTitleLower-intensity anticoagulation for mechanical heart valves: a new concept with the ATS bileaflet aortic valve J Heart Valve Dis 12 495–502 Occurrence Handle12918853

    PubMed  Google Scholar 

  9. T Mori M Asano H Ohtake A Bitoh S Sekiguchi Y Matsuo M Aiba M Yamada T Kawada T Takaba (2002) ArticleTitleAnticoagulant therapy after prosthetic valve replacement – optimal PT-INR in Japanese patients Ann Thorac Cardiovasc Surg 8 IssueID2 83–87 Occurrence Handle12027793

    PubMed  Google Scholar 

  10. H Koertke K Minami Th Breymann D Seifert O Wagner N Atmacha A Krian J Ennker U Taborski WP Klövekorn R Moosdorf W Saggau R Koerfer (2003) ArticleTitleINR self-management permits lower anticoagulation levels after mechanical heart valve replacement Circulation 108 IssueIDsuppl II II-75–II-78 Occurrence Handle1:STN:280:DC%2BD3svivV2itA%3D%3D

    CAS  Google Scholar 

  11. A Renzulli L De Luca A Caruso R Verde D Galzerano M Cotrufo (1992) ArticleTitleAcute thrombosis of prosthetic valves: a multivariate analysis of the risk factors for a lifethreatening event Eur J Cardiothorac Surg 6 412–420 Occurrence Handle10.1016/1010-7940(92)90065-6 Occurrence Handle1389247 Occurrence Handle1:STN:280:ByyD3c7isVE%3D

    Article  PubMed  CAS  Google Scholar 

  12. E Tayama Z Feng H Oda H Tomoeda N Hayashida S Fukunaga M Umezu S Aoyagi (2000) ArticleTitleATS prosthetic valve motion: an in vitro analysis J Heart Valve Dis 9 408–414 Occurrence Handle10888099 Occurrence Handle1:STN:280:DC%2BD3M%2FhsVOktA%3D%3D

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hideki Teshima MD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Teshima, H., Aoyagi, S., Hayashida, N. et al. Dysfunction of an ATS valve in the aortic position: the first reported case caused by pannus formation. J Artif Organs 8, 270–273 (2005). https://doi.org/10.1007/s10047-005-0317-9

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-005-0317-9

Key words

Navigation