Skip to main content
Log in

Feasibility study on fiber-optic goniometer for measuring knee joint angle

  • Special Section: The 9th International Conference on Optics-photonics Design & Fabrication “ODF’14, Itabashi, Tokyo”
  • Regular Papers
  • Published:
Optical Review Aims and scope Submit manuscript

Abstract

In this study, we fabricated a fiber-optic goniometer using a plastic optical fiber, a light-emitting diode, and a photodiode. The cladding of the plastic optical fiber was removed at 0.5–3mm intervals regularly to increase the bending loss of the plastic optical fiber. Also, the output voltages of the photodiode based on light intensity that measured using the fiber-optic goniometer were measured light intensities using the fiber-optic goniometer were measured to evaluate the linearity of the fiber-optic goniometer. Finally, we measured the responses of the fiber-optic goniometer for gait speeds of 3, 5, and 10 km/h using a data acquisition board and a LabVIEW program.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. S. Choi, H. S. Oh, D. W. Kang, K. R. Mun, M. H. Choi, S. J. Lee, J. W. Yang, S. C. Chung, S. W. Mun, and G. R. Tack: Int. J. Precis. Eng. Manuf. 12 (2011) 169.

    Article  Google Scholar 

  2. D. M. Karantonis, M. R. Narayanan, M. Mathie, N. H. Lovell, and B. G. Celler: IEEE Trans. Inf. Technol. Biomed. 10 (2006) 156.

    Article  Google Scholar 

  3. B. Culshaw and J. Dakin: Fiber Optic Sensors: Systems and Applications (Artech House, Norwood, MA, 1989).

    Google Scholar 

  4. M. M. Patil and O. Prohaska: Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., 1988, Vol. 2, p. 803.

    Article  Google Scholar 

  5. A. C. S. Brau, C. T. Wheeler, L. W. Hedlund, and G. A. Johnson: Magn. Resonance Med. 47 (2002) 314.

    Article  Google Scholar 

  6. B. Lee, W. Y. Choi, and J. K. Walker: Polym. Eng. Sci. 40 (2000) 1996.

    Article  Google Scholar 

  7. C. Davis, A. Mazzolini, and D. Murphy: Aust. Phys. Eng. Sci. Med. 20 (1997) 214.

    Google Scholar 

  8. E. Udd: Fiber-Optic Sensors: An introduction for Engineers and Scientists (Wiley, Hoboken, NJ, 1993) 2nd ed., p. 399.

    Google Scholar 

  9. M. Donno, E. Palange, F. D. Nicola, and G. Bucci: IEEE Trans. Instrum. Meas. 57 (2008) 1614.

    Article  Google Scholar 

  10. T. Oberg, A. Karsznia, and K. Oberg: J. Rehabil. Res. Dev. 31 (1994) 199.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Bongsoo Lee.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, S.G., Jang, K.W., Yoo, W.J. et al. Feasibility study on fiber-optic goniometer for measuring knee joint angle. OPT REV 21, 694–697 (2014). https://doi.org/10.1007/s10043-014-0112-z

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10043-014-0112-z

Keywords

Navigation