Isometric abdominal wall muscle strength assessment in individuals with incisional hernia: a prospective reliability study

  • Original Article
  • Published:
Hernia Aims and scope Submit manuscript

Abstract

Purpose

To determine the reliability of measurements obtained by the Good Strength dynamometer, determining isometric abdominal wall and back muscle strength in patients with ventral incisional hernia (VIH) and healthy volunteers with an intact abdominal wall.

Methods

Ten patients with VIH and ten healthy volunteers with an intact abdominal wall were each examined twice with a 1 week interval. Examination included the assessment of truncal flexion and extension as measured with the Good Strength dynamometer, the completion of the International Physical Activity Questionnaire (IPAQ) and the self-assessment of truncal strength on a visual analogue scale (SATS). The test–retest reliability of truncal flexion and extension was assessed by interclass correlation coefficient (ICC), and Bland and Altman graphs. Finally, correlations between truncal strength, and IPAQ and SATS were examined.

Results

Truncal flexion and extension showed excellent test–retest reliability for both patients with VIH (ICC 0.91 and 0.99) and healthy controls (ICC 0.97 and 0.96). Bland and Altman plots showed that no systematic bias was present for neither truncal flexion nor extension when assessing reliability. For patients with VIH, no significant correlations between objective measures of truncal strength and IPAQ or SATS were found. For healthy controls, both truncal flexion (τ 0.58, p = 0.025) and extension (τ 0.58, p = 0.025) correlated significantly with SATS, while no other significant correlation between truncal strength measures and IPAQ was found.

Conclusions

The Good Strength dynamometer provided a reliable, low-cost measure of truncal flexion and extension in patients with VIH.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Fink C, Baumann P, Wente MN, Knebel P, Bruckner T, Ulrich A, Werner J, Buchler MW, Diener MK (2014) Incisional hernia rate 3 years after midline laparotomy. Br J Surg 101:51–54

    Article  CAS  PubMed  Google Scholar 

  2. Sorensen LT, Hemmingsen UB, Kirkeby LT, Kallehave F, Jorgensen LN (2005) Smoking is a risk factor for incisional hernia. Arch Surg 140:119–123

    Article  PubMed  Google Scholar 

  3. van Ramshorst GH, Eker HH, Hop WC, Jeekel J, Lange JF (2012) Impact of incisional hernia on health-related quality of life and body image: a prospective cohort study. Am J Surg 204:144–150

    Article  PubMed  Google Scholar 

  4. Bellows CF, Robinson C, Fitzgibbons RJ, Webber LS, Berger DH (2014) Watchful waiting for ventral hernias: a longitudinal study. Am Surg 80:245–252

    PubMed  Google Scholar 

  5. Jensen KK, Henriksen NA, Harling H (2014) Standardized measurement of quality of life after incisional hernia repair: a systematic review. Am J Surg 208:485–493

    Article  PubMed  Google Scholar 

  6. Criss CN, Petro CC, Krpata DM, Seafler CM, Lai N, Fiutem J, Novitsky YW, Rosen MJ (2014) Functional abdominal wall reconstruction improves core physiology and quality-of-life. Surgery 156:176–182

    Article  PubMed  Google Scholar 

  7. Gunnarsson U, Johansson M, Strigard K (2011) Assessment of abdominal muscle function using the Biodex System-4. Validity and reliability in healthy volunteers and patients with giant ventral hernia. Hernia 15:417–421

    Article  CAS  PubMed  Google Scholar 

  8. Stark B, Emanuelsson P, Gunnarsson U, Strigard K (2012) Validation of Biodex system 4 for measuring the strength of muscles in patients with rectus diastasis. J Plast Surg Hand Surg 46:102–105

    Article  PubMed  Google Scholar 

  9. Fraser A, Vallow J, Preston A, Cooper RG (1999) Predicting ‘normal’ grip strength for rheumatoid arthritis patients. Rheumatology (Oxford, England) 38:521–528

    Article  CAS  Google Scholar 

  10. Craig CL, Marshall AL, Sjostrom M, Bauman AE, Booth ML, Ainsworth BE, Pratt M, Ekelund U, Yngve A, Sallis JF, Oja P (2003) International physical activity questionnaire: 12-country reliability and validity. Med Sci Sports Exerc 35:1381–1395

    Article  PubMed  Google Scholar 

  11. Rankin G, Stokes M (1998) Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses. Clin Rehabil 12:187–199

    Article  CAS  PubMed  Google Scholar 

  12. Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310

    Article  CAS  PubMed  Google Scholar 

  13. Hopkins WG (2000) Measures of reliability in sports medicine and science. Sports Med 30:1–15

    Article  CAS  PubMed  Google Scholar 

  14. Giavarina D (2015) Understanding Bland Altman analysis. Biochem Med (Zagreb) 25:141–151

    Article  Google Scholar 

  15. Chastin SF, Culhane B, Dall PM (2014) Comparison of self-reported measure of sitting time (IPAQ) with objective measurement (activPAL). Physiol Meas 35:2319–2328

    Article  CAS  PubMed  Google Scholar 

  16. Hallal PC, Gomez LF, Parra DC, Lobelo F, Mosquera J, Florindo AA, Reis RS, Pratt M, Sarmiento OL (2010) Lessons learned after 10 years of IPAQ use in Brazil and Colombia. J Phys Act Health 7(Suppl 2):S259–S264

    Article  PubMed  Google Scholar 

  17. Lachin JM (2004) The role of measurement reliability in clinical trials. Clin Trials 1:553–566

    Article  PubMed  Google Scholar 

  18. Hopman-Rock M, Kraaimaat FW, Bijlsma JW (1997) Quality of life in elderly subjects with pain in the hip or knee. Qual Life Res 6:67–76

    Article  CAS  PubMed  Google Scholar 

  19. Badia X, Monserrat S, Roset M, Herdman M (1999) Feasibility, validity and test-retest reliability of scaling methods for health states: the visual analogue scale and the time trade-off. Qual Life Res 8:303–310

    Article  CAS  PubMed  Google Scholar 

  20. Stroyer J, Essendrop M, Jensen LD, Warming S, Avlund K, Schibye B (2007) Validity and reliability of self-assessed physical fitness using visual analogue scales. Percept Mot Skills 104:519–533

    Article  PubMed  Google Scholar 

  21. Janevic MR, McLaughlin SJ, Connell CM (2012) Overestimation of physical activity among a nationally representative sample of underactive individuals with diabetes. Med Care 50:441–445

    Article  PubMed  PubMed Central  Google Scholar 

  22. Jensen KK, Kjaer M, Jorgensen LN (2014) Abdominal muscle function and incisional hernia: a systematic review. Hernia 18:481–486

    Article  CAS  PubMed  Google Scholar 

  23. Parker M, Goldberg RF, Dinkins MM, Asbun HJ, Daniel Smith C, Preissler S, Bowers SP (2011) Pilot study on objective measurement of abdominal wall strength in patients with ventral incisional hernia. Surg Endosc 25:3503–3508

    Article  PubMed  Google Scholar 

  24. DuBay DA, Choi W, Urbanchek MG, Wang X, Adamson B, Dennis RG, Kuzon WM Jr, Franz MG (2007) Incisional herniation induces decreased abdominal wall compliance via oblique muscle atrophy and fibrosis. Ann Surg 245:140–146

    Article  PubMed  PubMed Central  Google Scholar 

  25. Culbertson EJ, Xing L, Wen Y, Franz MG (2013) Reversibility of abdominal wall atrophy and fibrosis after primary or mesh herniorrhaphy. Ann Surg 257:142–149

    Article  PubMed  PubMed Central  Google Scholar 

  26. Colavita PD, Tsirline VB, Belyansky I, Walters AL, Lincourt AE, Sing RF, Heniford BT (2012) Prospective, long-term comparison of quality of life in laparoscopic versus open ventral hernia repair. Ann Surg 256:714–722

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to K. K. Jensen.

Ethics declarations

Conflict of interest

KJ declares no conflicts of interest. MK declares no conflicts of interest. LJ declares no conflicts of interest.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jensen, K.K., Kjaer, M. & Jorgensen, L.N. Isometric abdominal wall muscle strength assessment in individuals with incisional hernia: a prospective reliability study. Hernia 20, 831–837 (2016). https://doi.org/10.1007/s10029-016-1497-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10029-016-1497-3

Keywords

Navigation