In vivo MRI visualization of parastomal mesh in a porcine model

  • Original Article
  • Published:
Hernia Aims and scope Submit manuscript

Abstract

Introduction

After two-dimensional plane MRI-visible mesh implants could be successfully visualized in phantom and small animal model, the aim of the underlying study was to explore the feasibility of an MRI visualization of complex three-dimensional mesh geometry in close contact to the intestine. We therefore used a MR-visible three-dimensional intra-peritoneal stoma (IPST) mesh in a porcine model.

Materials and methods

Laparoscopic terminal sigmoid colostomy has been done with implantation of a prophylactic MRI-visible IPST mesh in two animals. MRI investigations were done after 1 week, 6 months and in case of clinical impairment. These findings were compared to endoscopy and makroscopical and histological investigation of the preparation.

Results

The first animal has to be killed because of an ileus 4 weeks after operation. The second animal has to be killed after 7 weeks because of recurrent obstipation. In all cases MRI investigation could identify the IPST mesh and could clearly separate between mesh and intestine. MRI revealed a big bowl ileus due to a funnel dislocation in the first animal. In the second animal, MR diagnostic explored a functional stenosis because of a too small diameter of the central funnel in combination with sticky feces and distension of the terminal sigmoid before discharging into the funnel. Endoscopy, makroscopical and histological investigation of the preparation supported MRI findings.

Conclusion

Although complicate clinical course was a diagnostic challenge exploring 3D implants such as IPST, visualization of this new MRI-visible IPST mesh could be proved and turned out as an effective diagnostic possibility. Further studies are necessary to analyze long-time effects such as shrinkage, mesh migration and tissue integration using MRI scanning.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Crespi G, Giannetta E, Mariani F, Floris F, Pretolesi F, Marino P (2004) Imaging of early postoperative complications after polypropylene mesh repair of inguinal hernia. Radiol Med 108:107–115

    PubMed  Google Scholar 

  2. Rakic S, LeBlanc KA (2013) The radiologic appearance of prosthetic materials used in hernia repair and a recommended classification. AJR Am J Roentgenol 201:1180–1183

    Article  PubMed  Google Scholar 

  3. Fischer T, Ladurner R, Gangkofer A, Mussack T, Reiser M, Lienemann A (2007) Functional cine MRI of the abdomen for the assessment of implanted synthetic mesh in patients after incisional hernia repair: initial results. Eur Radiol 17:3123–3129

    Article  PubMed  Google Scholar 

  4. Zinther NB, Wara P, Friis-Andersen H (2010) Shrinkage of intraperitoneal onlay mesh in sheep: coated polyester mesh versus covered polypropylene mesh. Hernia 14:611–615

    Article  PubMed  CAS  Google Scholar 

  5. Kirchhoff S, Ladurner R, Kirchhoff C, Mussack T, Reiser MF, Lienemann A (2010) Detection of recurrent hernia and intraabdominal adhesions following incisional hernia repair: a functional cine MRI-study. Abdom Imaging 35:224–231

    Article  PubMed  CAS  Google Scholar 

  6. Widmaier S, Jung WI, Pfeffer K, Pfeffer M, Lutz O (1993) MRI and determination of T1 and T2 of solid polymers using a 1.5 T whole-body imager. Magn Reson Imaging 11:733–737

    Article  PubMed  CAS  Google Scholar 

  7. Springer F, Martirosian P, Schwenzer NF, Szimtenings M, Kreisler P, Claussen CD, Schick F (2008) Three-dimensional ultrashort echo time imaging of solid polymers on a 3-Tesla whole-body MRI scanner. Invest Radiol 43:802–808

    Article  PubMed  Google Scholar 

  8. Kraemer NA, Donker HCW, Otto J, Hodenius M, Sénégas J, Slabu I, Klinge U, Baumann M, Müllen A, Obolenski B, et al. (2010) A concept for magnetic resonance visualization of surgical textile implants. Invest Radiol 45:477–483

    Article  Google Scholar 

  9. Donker HC, Krämer NA, Otto J, Klinge U, Slabu I, Baumann M, Kuhl CK (2012) Mapping of proton relaxation near superparamagnetic iron oxide particle-loaded polymer threads for magnetic susceptibility difference quantification. Invest Radiol 47:359–367

    Article  PubMed  CAS  Google Scholar 

  10. Slabu I, Guntherodt G, Schmitz-Rode T, Hodenius M, Kramer N, Donker H, Krombach GA, Otto J, Klinge U, Baumann M (2012) Investigation of superparamagnetic iron oxide nanoparticles for MR-visualization of surgical implants. Curr Pharm Biotechnol 13:545–551

  11. Kuehnert N, Kraemer NA, Otto J, Donker HCW, Slabu I, Baumann M, Kuhl CK, Klinge U In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides. Surg Endosc

  12. Kraemer NA, Donker HC, Kuehnert N, Otto J, Schrading S, Krombach GA, Klinge U, Kuhl CK (2013) In vivo visualization of polymer-based mesh implants using conventional magnetic resonance imaging and positive-contrast susceptibility imaging. Invest Radiol 48:200–205

    PubMed  CAS  Google Scholar 

  13. Hansen NL, Barabasch A, Distelmaier M, Ciritsis A, Kuehnert N, Otto J, Conze J, Klinge U, Hilgers RD, Kuhl CK, Kraemer NA (2013) First in-human magnetic resonance visualization of surgical mesh implants for inguinal hernia treatment. Invest Radiol 48(11):770–778. doi:10.1097/RLI.0b013e31829806ce

    Article  PubMed  CAS  Google Scholar 

  14. Kuehnert N, Kraemer NA, Otto J, Donker HC, Slabu I, Baumann M, Kuhl CK, Klinge U (2012) In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides. Surg Endosc 26:1468–1475

    Article  PubMed  PubMed Central  Google Scholar 

  15. Otto J, Kuehnert N, Kraemer NA, Ciritsis A, Hansen NL, Kuhl C, Busch D, Peter Neumann U, Klinge U, Conze KJ (2014) First in vivo visualization of MRI-visible IPOM in a rabbit model. J Biomed Mater Res B Appl Biomater. doi:10.1002/jbm.b.33098

  16. Berger D, Bientzle M (2009) Polyvinylidene fluoride: a suitable mesh material for laparoscopic incisional and parastomal hernia repair! A prospective, observational study with 344 patients. Hernia 13:167–172

    Article  PubMed  CAS  Google Scholar 

  17. Berger D (2008) Prevention of parastomal hernias by prophylactic use of a specially designed intraperitoneal onlay mesh (Dynamesh IPST). Hernia 12:243–246

    Article  PubMed  CAS  Google Scholar 

  18. Krämer NA, Donker HC, Otto J, Hodenius M, Sénégas J, Slabu I, Klinge U, Baumann M, Müllen A, Obolenski B et al (2010) A concept for magnetic resonance visualization of surgical textile implants. Invest Radiol 45:477–483

    Article  PubMed  Google Scholar 

  19. Tadeo G, Picazo J, Moreno C, Cuesta R (2012) A comparison of two types of preperitoneal mesh prostheses in stoma surgery: application to an animal model. Hernia 16(6):669–675. doi:10.1007/s10029-012-0966-6

    Article  PubMed  CAS  Google Scholar 

  20. Berger D (2010) [Laparoscopic IPOM technique]. Der Chirurg; Zeitschrift für alle Gebiete der operativen Medizen, 81:211–215

  21. Klink CD, Junge K, Binnebösel M, Alizai HP, Otto J, Neumann UP, Klinge U (2011) Comparison of long-term biocompability of PVDF and PP meshes. J Invest Surg 24:292–299

    Article  PubMed  CAS  Google Scholar 

  22. Jänes A, Cengiz Y, Israelsson LA (2009) Preventing parastomal hernia with a prosthetic mesh: a 5-year follow-up of a randomized study. World J Surg 33:118–121 discussion 122–113

    Article  PubMed  Google Scholar 

Download references

Conflict of interest

Declaration of conflict of interest: JO, DB, CK, AW, NK, AC, CK and UN declare no conflict of interest. UK declares conflict of interest not directly related to the submitted work (Expert testimony, consulting for FEG, presentations for Braun, Ethicon, Lifecell). JC declares conflict of interest not directly related to the submitted work (Consulting for Ethicon, presentation for Bard, Gore).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. Otto.

Additional information

J. Conze and N. Kraemer contributed equally for last authorship.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Otto, J., Busch, D., Klink, C. et al. In vivo MRI visualization of parastomal mesh in a porcine model. Hernia 18, 663–670 (2014). https://doi.org/10.1007/s10029-014-1270-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10029-014-1270-4

Keywords

Navigation