Abstract
A new modified carbon paste electrode based on a recently synthesized mercury (II) complex of a pyridine containing proton transfer compound as a suitable carrier for Br− ion is described. The electrode has a linear dynamic range between 3.00×10−2 and 1.0×10−5 M with a near-Nernastian slope of 61.0±0.9 mV per decade and a detection limit of 4.0×10−6 M (0.32 ppm). The potentiometric response is independent of the pH of the solution in the pH range 4.0–8.3. The electrode possesses the advantages of low resistance, fast response and good over a variety of other anions. It was applied as an indicator electrode in potentiometric titration of bromide ions and for the recovery of Br− from tap water.
Similar content being viewed by others
References
Kalcher K, Kauffmann JM, Wang J, Svancara I, Vytras K, Neuhold C, Yang Z (1995) Electroanalysis 7: 5
Kissinger PT, Heineman WR (1996) Laboratory techniques in electroanalytical chemistry. 2nd edition. Dekker, New York
Wang J (2000) Electroanalytical chemistry. 2nd edition. Wiley, New York
Modgley D, Mulcahy DE (1983) Ion-Sel Electrode Rev 5:165
Wang J, Kirgoz UA, Mo J-W, Lu J, Kawde AN, Muck A (2001) Electrochem Commun 3:203
Abbas MN (2003) Anal Sci 19:229
Amini MK, Khorasani JH, Khaloo SS, Tangestaninejad S (2003) Anal Biochem 320:32
Mesaric S, Dahmen EAMF (1973) Anal Chim Acta 64: 431
Gismera MJ, Mendiola MA, Procopio JR, Sevilla MT (1999) Anal Chim Acta 385:143
Jezkova J, Musibva J, Vytras K (1997) Electroanalysis 9:1433
Shamsipur M, Soleymanpour A, Akhond M, Sharghi H, Naseri MA (2001) Anal Chim Acta 450:37
Abbas MN, Mostafa GAE (2003) J Pharmaceut Biomed Anal 31:819
Ozoemena KI, Stefan R-I, Van Staden JF, Aboul-enein HY (224) Talanta 62:681
Umezawa Y (1990) CRC handbook of ion-selective electrodes. CRC Press, Boca Raton
Pranitis DM, Telting-Diaz M, Meyerhoff ME (1992) Crit Rev Anal Chem 23:163
Xiao KP, Bühlmann P, Nishizawa S, Amemiya S, Umezawa Y (1997) Anal Chem 69:1038
Kim W, Sung DD, Cha GS, Park SB (1998) Analyst 123:379
Kimura K, Takase H, Yajima S, Yokoyama M (1999) Analyst 124:517
Huber C, Werner T, Krause C, Wolfbeis OS (1999) Analyst, 124:1617
Oh KC, Kim KA, Paeng IR, Baek DJ, Paeng KJ (1999) J Electroanal Chem 468:98
El Aamrani FZ, Gareiá-Raurich J, Sastre A, Beyer L, Florido A (1999) Anal Chim Acta 409:129
Shamsipur M, Sadeghi S, Naeimi H (2000) Polish J Chem 74:231
Ganjali MR, Poursaberi T, Hosseini M, Salavati-Niasary M, Yousefi M, Shamsipur M (2002) Anal Sci 18:289
Poursaberi T, Hosseini M, Taghizadeh M, Pirelahi H, Shamsipur M, Ganjali MR (2002) Microchem J 72:77
Farhadi K, Maleki R, Hosseinzadeh Yamchi R, Sharghi H, Shamsipur M (2004) Anal Sci 20:805
James H, Carmack G, Freiser H (1972) Anal Chem 44:856
Tseng PKC (1976) Anal Lett 9:795
Viaso YG, Moskin LN, Bychkov EA, Glikov DV (1989) Analyst 114:185
Shamsipur M, Rouhani S, Mohajeri A, Ganjali MR, Rashidi-Ranjbar P (2000) Anal Chim Acta 418:177
Ganjali MR, Tahami M, Poursaberi T, Pazoukian AR, Javanbakht M, Shamsipur M, Baezat MR (2003) Anal Lett 36:347
Rouhollahi A, Shamsipur M (1999) Anal Chem 71:1350
Shamsipur M, Poursaberi T, Rezapour M, Ganjali MR, Mousavi MF, Lippolis V, Montesu DR (2002) Electroanalysis 28:141
Shamsipur M, Soleymanour A, Akhond M, Sharghi H, Hasaninejad AR (2003) Sens Actuators B 89:9
Shamsipur M, Javanbakht M, Hasaninejad AR, Sharghi H, Ganjali MR, Mousavi MF (2003) Electroanalysis 15:1251
Ganjali MR, Mizani F, Emami M, Salavati Niasari M, Shamsipur M, Yousefi M, Javanbakht M (2003) Electroanalysis 15:139
Shamsipur M, Yousefi M, Hosseini M, Ganjali MR, Sharghi H, Naeimi H (2001) Anal Chem 73:2869
Moghimi A, Shokrollahi A, Shamsipur M, Aghabozorg H, Ranjbar M (2004) J Mol Struct 701:49
Hofmeister P (1888) Arch Exp Pathol Pharmacol 60:185
IUPAC Analytical Chemistry Division, Commission on analytical nomenclature, recommendations for nomenclature of ion selective electrodes (1976) Pure Appl Chem 48:127
Bailey PL (1996) Analysis with ion-selective electrodes. Heyden, London
Gadzepco VP, Christian GD (1984) Anal Chim Acta 164:279
Umezawa Y, Umezawa K, Sato H (1995) Pure Appl Chem 67:507
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Shamsipur, M., Ershad, S., Samadi, N. et al. A novel chemically modified carbon paste electrode based on a new mercury(II) complex for selective potentiometric determination of bromide ion. J Solid State Electrochem 9, 788–793 (2005). https://doi.org/10.1007/s10008-005-0692-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10008-005-0692-4