Abstract
Objectives
To evaluate the influence of sharpening filters in the detection of root fractures using low-dose cone-beam computed tomography (CBCT).
Materials and methods
Eighty-four CBCT volumes acquired at three mA levels of 28 teeth inserted in the dental socket of dry human skull were selected from a previous study. The teeth were divided into four groups according to the presence and absence of root fracture and endodontic filling. Five radiologists evaluated all CBCT volumes for the presence of root fracture with and without the application of “Sharpen 1x” and “Sharpen 2x” filters in OnDemand3D software. Area under the ROC curve (AUC), sensitivity, specificity, and inter- and intra-observer concordance were calculated and compared (α = 0.05).
Results
Sharpening filters did not lead to significant differences in AUC, sensitivity, and specificity at the three mA levels tested (p > 0.05), regardless of the presence of endodontic filling (p > 0.05). However, the significant reduction of AUC observed in CBCT volumes at 4 mA without filter (p < 0.05) ceased to exist after the application of filters (p > 0.05). Sensitivity and specificity ranged from low and moderate.
Conclusions
The use of sharpening filters can be recommended in CBCT volumes at 4 mA for root fracture detection for leading to the same performance as those at 6.3 and 10 mA. The presence of endodontic filling material did not influence the action of filters in the diagnosis of root fracture.
Clinical relevance
Sharpening filters seem to contribute to the diagnosis of root fracture in CBCT volumes acquired with reduced radiation dose.
Similar content being viewed by others
References
Dias DR, Iwaki LCV, de Oliveira ACA, Martinhão FS, Rossi RM, Araújo MG, Hayacibara RM (2020) Accuracy of high-resolution small-volume cone-beam computed tomography in the diagnosis of vertical root fracture: an in vivo analysis. J Endod 46:1059–1066. https://doi.org/10.1016/j.joen.2020.04.015
Pinto MGO, Rabelo KA, Sousa Melo SL, Campos PSF, Oliveira LSAF, Bento PM, Melo DP (2017) Influence of exposure parameters on the detection of simulated root fractures in the presence of various intracanal materials. Int Endod J 50:586–594. https://doi.org/10.1111/iej.12655
Tsesis I, Kamburoǧlu K, Katz A, Tamse A, Kaffe I, Kfir A (2008) Comparison of digital with conventional radiography in detection of vertical root fractures in endodontically treated maxillary premolars: an ex vivo study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106:124–128. https://doi.org/10.1016/j.tripleo.2007.09.007
Avsever H, Gunduz K, Orhan K, Uzun I, Ozmen B, Egrioglu E, Millidi M (2014) Comparison of intraoral radiography and cone-beam computed tomography for the detection of horizontal root fractures: an in vitro study. Clin Oral Investig 18:285–292. https://doi.org/10.1007/s00784-013-0940-4
Chang E, Lam E, Shah P, Azarpazhooh A (2016) Cone-beam computed tomography for detecting vertical root fractures in endodontically treated teeth: a systematic review. J Endod 42:177–185. https://doi.org/10.1016/j.joen.2015.10.005
Brady E, Mannocci F, Brown J, Wilson R, Patel SA (2014) Comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth. Int Endod J 47:735–746. https://doi.org/10.1111/iej.12209
Yiit Özer S (2010) Detection of vertical root fractures of different thicknesses in endodontically enlarged teeth by cone beam computed tomography versus digital radiography. J Endod 36:1245–1249. https://doi.org/10.1016/j.joen.2010.03.021
Gaêta-Araujo H, Silva de Souza GQ, Freitas DQ, de Oliveira-Santos C (2017) Optimization of tube current in cone-beam computed tomography for the detection of vertical root fractures with different intracanal materials. J Endod 43:1668–16673. https://doi.org/10.1016/j.joen.2017.04.003
Talwar S, Utneja S, Nawal RR, Kaushik A, Srivastava D, Oberoy SS (2016) Role of cone- beam computed tomography in diagnosis of vertical root fractures: a systematic review and meta-analysis. J Endod 42:12–24. https://doi.org/10.1016/j.joen.2015.09.012
Patel S, Brown J, Pimentel T, Kelly RD, Abella F, Durack C (2019) Cone beam computed tomography in Endodontics – a review of the literature. Int Endod J 52:1138–1152. https://doi.org/10.1111/iej.13115
Nascimento HAR, Andrade MEA, Frazão MAG, Nascimento EHL, Ramos-Perez FMM, Freitas DQ (2017) Dosimetry in CBCT with different protocols: emphasis on Small FOVs including exams for TMJ. Braz Dent J 28:511–516. https://doi.org/10.1590/0103-6440201701525
Goulston R, Davies J, Horner K, Murphy F (2016) Dose optimization by altering the operating potential and tube current exposure time product in dental cone beam CT: A systematic review. Dentomaxillofac Radiol 45:2–16. https://doi.org/10.1590/0103-6440201701525
Pauwels R, Seynaeve L, Henriques JCG, De Oliveira-Santos C, Souza PC, Westphalen FH, Rubira-Bullen IRF et al (2015) Optimization of dental CBCT exposures through mAs reduction. Dentomaxillofac Radiol 44:20150108. https://doi.org/10.1259/dmfr.20150108
Tangari-Meira R, Vancetto JR, Dovigo LN, Tosoni GM (2017) Influence of tube current settings on diagnostic detection of root fractures using cone-beam computed tomography: an in vitro study. J Endod 43:1701–1705. https://doi.org/10.1016/j.joen.2017.05.008
Choi JW, Han WJ, Kim EK (2014) Image enhancement of digital periapical radiographs according to diagnostic tasks. Imaging Sci Dent 44:31–35. https://doi.org/10.5624/isd.2014.44.1.31
De Martin e Silva D, Campos CN, Pires Carvalho AC, Devito KL (2018) Diagnosis of mesiodistal vertical root fractures in teeth with metal posts: influence of applying filters in cone-beam computed tomography images at different resolutions. J Endod 44:470–474. https://doi.org/10.1016/j.joen.2017.08.030
De Azevedo Vaz SL, Vasconcelos TV, Neves FS, De Freitas DQ, Haiter-Neto F (2012) Influence of cone-beam computed tomography enhancement filters on diagnosis of simulated external root resorption (2012). J Endod 38:305–308. https://doi.org/10.1016/j.joen.2011.10.012
Nascimento MCC, Nejaim Y, De Almeida SM, Bóscolo FN, Haiter-Neto F, Sobrinho LC, Silva EJNL (2014) Influence of cone beam CT enhancement filters on diagnosis ability of longitudinal root fractures. Dentomaxillofac Radiol 43:20130374. https://doi.org/10.1259/dmfr.20130374
Wenzel A, Haiter-Neto F, Frydenberg M, Kirkevang LL (2009) Variable-resolution cone- beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 108:939–945. https://doi.org/10.1016/j.tripleo.2009.07.041
Ferreira LM, Visconti MAPG, Nascimento HA, Dallemolle RR, Ambrosano GM, Freitas DQ (2015) Influence of CBCT enhancement filters on diagnosis of vertical root fractures: A simulation study in endodontically treated teeth with and without intracanal posts. Dentomaxillofac Radiol 44:2–7. https://doi.org/10.1259/dmfr.20140352
Verner FS, D’Addazio PS, Campos CN, Devito KL, Almeida SM, Junqueira RB (2017) Influence of cone-beam computed tomography filters on diagnosis of simulated endodontic complications. Int Endod J 50:1089–1096. https://doi.org/10.1111/iej.12732
de Sousa ET, Pinheiro MA, Maciel PP, Sales MAO (2017) Influence of enhancement filters in apical bone loss measurement: a cone-beam computed tomography study. J Clin Exp Dent 9:e516-519. https://doi.org/10.4317/jced.53496
Landis JR, Koch GG (1997) An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers. Biometrics 33:363–374
Wanderley VA, Freitas DQ, Haiter-Neto F, Oliveira ML (2018) Influence of tooth orientation on the detection of vertical root fracture in cone-beam computed tomography. J Endod 44:1168–1172. https://doi.org/10.1016/j.joen.2018.04.006
Marinho Vieira LE, Diniz de Lima E, Peixoto LR, Oliveira Pinto MG, Sousa Melo SL, Oliveira ML, Silva KR (2020) Assessment of the influence of different intracanal materials on the detection of root fracture in birooted teeth by cone-beam computed tomography. J Endod 46:264–270. https://doi.org/10.1016/j.joen.2019.10.028
Sagawa M, Miyoseta Y, Hayakawa Y, Honda A (2009) Comparison of two - and three- dimensional filtering methods to improve image quality in multiplanar reconstruction of cone-beam computed tomography. Oral Radiol 25:154–168. https://doi.org/10.1007/s11282-009-0026-9
The, (2007) Recommendations of the international commission on radiological protection. ICRP publication 103 (2007). Ann ICRP 37:1–332
Neves FS, Freitas DQ, Campos PSF, Ekestubbe A, Lofthag-Hansen S (2014) Evaluation of cone-beam computed tomography in the diagnosis of vertical root fractures: the influence of imaging modes and root canal materials. J Endod 40:1530–1536. https://doi.org/10.1016/j.joen.2014.06.012
Elsaltani MH, Farid MM, Eldin Ashmawy MS (2016) Detection of simulated vertical root fractures: which cone-beam computed tomographic system is the most accurate? J Endod 42:972–977. https://doi.org/10.1016/j.joen.2016.03.013
Fayad MI, Ashkenaz PJ, Johnson BR (2012) Different representations of vertical root fractures detected by cone-beam volumetric tomography: a case series report. J Endod 38:1435–1442. https://doi.org/10.1016/j.joen.2012.05.015
Pauwels R, Silkosessak O, Bogaerts JR, Bosmans H, Panmekiate S (2014) A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose. Dentomaxillofac Radiol 43:20140059. https://doi.org/10.1259/dmfr.20140059
Panmekiate S, Rungwittayathon P, Suptaweeponboon W, Tangtraitham N, Pauwels R (2018) Optimization of exposure parameters in dental cone beam computed tomography using a 3-step approach. Oral Surg Oral Med Oral Pathol Oral Radiol 126:545–552. https://doi.org/10.1016/j.oooo.2018.08.004
Candemil AP, Salmon B, Vasconcelos KF, Oenning AC, Jacobs R, Freitas DQ, Haiter-Neto F, Mangione F et al (2021) Cone beam CT optimisation for detection of vertical root fracture with metal in the field of view or the exomass. Sci Rep 11:19155. https://doi.org/10.1038/s41598-021-98345-6
Funding
This study was financed in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior — Brasil (CAPES) — Finance Code 001.
Author information
Authors and Affiliations
Contributions
All authors contributed to the study’s conception and design. Material preparation and data collection were performed by Alexandra Robles González, Guilherme Monteiro Tosoni, and Matheus L. Oliveira and statistical analysis were performed by Deborah Queiroz Freitas. The first draft of the manuscript was written by Alexandra Robles González, and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethical approval
All procedures performed in this study were conducted in accordance with the ethical standards of the Human Research Ethics Committee of Piracicaba Dental School, University of Campinas, Brazil (protocol number #36695920.4.0000.5418) and with the Helsinki Declaration.
Informed consent
Not applicable.
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
González, A.R., Tosoni, G.M., Freitas, D.Q. et al. Influence of sharpening filters on the detection of root fractures using low-dose cone-beam computed tomography. Clin Oral Invest 26, 4797–4803 (2022). https://doi.org/10.1007/s00784-022-04444-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00784-022-04444-7