Abstract
This clinical study evaluated posterior three-unit fixed dental prostheses (FDPs) made of zirconia substructures veneered with pressable glass–ceramic. Nineteen patients received 21 FDPs replacing either the second premolar, first molar, or second molar. The FDPs were cemented with glass ionomer. Recall examinations were performed every 12 months. The mean service time of the FDP was 40 months. At 30 months, one maxillary FDP exhibited zirconia framework fracture at a thinned occlusal area of the abutment. Loss of retention led to the removal of one FDP after 38 months. The Kaplan–Meier survival probability was 90.5% after 40 months for all types of failures and 95.2% concerning framework fractures. The overpressing technique appears to be reliable in terms of the veneering material. However, one framework fracture was observed in this study.
Similar content being viewed by others
References
Aboushelib MN, de Jager N, Kleverlaan CJ, Feilzer AJ (2005) Microtensile bond strength of different components of core veneered all-ceramic restorations. Dent Mater 21:984–991
Aboushelib MN, Kleverlaan CJ, Feilzer AJ (2006) Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: zirconia veneering ceramics. Dent Mater 22:857–863
Barnfather KD, Brunton PA (2007) Restoration of the upper dental arch using Lava all-ceramic crown and bridgework. Br Dent J 202:731–735
Beuer F, Steff B, Naumann M, Sorensen J (2008) Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated materials. Eur J Oral Sci 116:381–386
Beuer F, Aggstaller H, Edelhoff D, Gernet W, Sorensen J (2009) Marginal and internal fits of fixed dental prostheses zirconia retainers. Dent Mater 25:94–102
Beuer F, Schweiger J, Eichberger M, Kappert HF, Gernet W, Edelhoff D (2009) High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings—a new fabrication mode for all-ceramic restorations. Dent Mater 25:121–128
Creugers NH, Kayser AF, van 't Hof MA (1994) A meta-analysis of durability data on conventional fixed bridges. Community Dent Oral Epidemiol 22:448–452
Esquivel-Upshaw JF, Anusavice KJ, Young H, Jones J, Gibbs C (2004) Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs. Int J Prosthodont 17:469–475
Esquivel-Upshaw JF, Young H, Jones J, Yang M, Anusavice KJ (2008) Four-year clinical performance of a lithia disilicate-based core ceramic for posterior fixed partial dentures. Int J Prosthodont 21:155–160
Herrero AA, Sierraalta M, Razzoog ME (2006) Flexural strength of several porcelain systems for zirconium ceramics. J Dent Res 85:abstract 1355
John MT, Zwijnenburg AJ (2001) Interobserver variability in assessment of signs of TMD. Int J Prosthodont 14:265–270
John MT, Hirsch C, Reiber T, Dworkin S (2006) Translating the research diagnostic criteria for temporomandibular disorders into German: evaluation of content and process. J Orofac Pain 20:43–52
Kohorst P, Herzog TJ, Borchers L, Stiesch-Scholz M (2007) Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks. Eur J Oral Sci 115:161–166
Loe H, Silness J (1963) Periodontal disease in pregnancy. I. Prevalence and severity. Acta Odontol Scand 21:533–551
Luthy H, Filser F, Loeffel O, Schumacher M, Gauckler L, Hammerle CH (2005) Strength and reliability of four unit all-ceramic posterior bridges. Dent Mater 21:930–937
Marquardt P, Strub JR (2006) Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study. Quintessence Int 37:253–259
Molin MK, Karlsson SL (2008) Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 21:223–227
Muehlemann HR, Schroeder HE (1964) Dynamics of supragingival calculus formation. Adv Oral Biol 1:175–203
O'Leary T (1974) Indices for measurement of tooth mobility in clinical studies. J Periodontal Res Suppl 14:94–105
Olsson KG, Furst B, Andersson B, Carlsson GE (2003) A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs. Int J Prosthodont 16:150–156
Raigrodski AJ, Chiche GJ (2002) All-ceramic fixed partial dentures, Part I: in vitro studies. J Esthet Restor Dent 14:188–191
Raigrodski AJ, Chiche GJ, Swift EJ Jr. (2002) All-ceramic fixed partial dentures, Part III: clinical studies. J Esthet Restor Dent 14:313–319
Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S et al (2006) The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent 96:237–244
Ries S, Wolz J, Richter EJ (2006) Effect of design of all-ceramic resin-bonded fixed partial dentures on clinical survival rate. Int J Periodontics Restorative Dent 26:143–149
Sailer I, Feher A, Filser F, Luthy H, Gauckler LJ, Scharer P et al (2006) Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up. Quintessence Int 37:685–693
Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388
Sailer I, Holderegger C, Jung RE, Suter A, Thievent B, Pietrobon N et al (2007) Clinical study of the color stability of veneering ceramics for zirconia frameworks. Int J Prosthodont 20:263–269
Sailer I, Pjetursson BE, Zwahlen M, Hammerle CH (2007) A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses. Clin Oral Implants Res 18(Suppl 3):86–96
Schmitter M, Ohlmann B, John MT, Hirsch C, Rammelsberg P (2005) Research diagnostic criteria for temporomandibular disorders: a calibration and reliability study. Cranio 23:212–218
Scurria MS, Bader JD, Shugars DA (1998) Meta-analysis of fixed partial denture survival: prostheses and abutments. J Prosthet Dent 79:459–464
Silness J, Loe H (1964) Periodontal disease in pregnancy. Ii. Correlation between oral hygiene and periodontal condition. Acta Odontol Scand 22:121–135
Sulaiman F, Chai J, Jameson LM, Wozniak WT (1997) A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns. Int J Prosthodont 10:478–484
Taskonak B, Mecholsky JJ Jr, Anusavice KJ (2006) Fracture surface analysis of clinically failed fixed partial dentures. J Dent Res 85:277–281
Taskonak B, Sertgoz A (2006) Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures. Dent Mater 22:1008–1013
Tinschert J, Zwez D, Marx R, Anusavice KJ (2000) Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics. J Dent 28:529–535
Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H (2001) Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont 14:231–238
Tinschert J, Natt G, Mohrbotter N, Spiekermann H, Schulze KA (2007) Lifetime of alumina- and zirconia ceramics used for crown and bridge restorations. J Biomed Mater Res B Appl Biomater 80:317–321
Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H (2008) Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 21:217–222
Tsalouchou E, Cattell MJ, Knowles JC, Pittayachawan P, McDonald A (2008) Fatigue and fracture properties of yttria partially stabilized zirconia crown systems. Dent Mater 24:308–318
Vult von Steyern P, Jonsson O, Nilner K (2001) Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs. Int J Prosthodont 14:379–384
Vult von Steyern P, Carlson P, Nilner K (2005) All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 32:180–187
Walter M, Reppel PD, Boning K, Freesmeyer WB (1999) Six-year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures. J Oral Rehabil 26:91–96
Witkowski S, Komine F, Gerds T (2006) Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques. J Prosthet Dent 96:47–52
Acknowledgments
This study was funded by DeguDent. The authors wish to sincerely thank Josef Schweiger, Marlis Eichberger, and John Meinen for fabricating the restorations at the laboratory of Munich Dental School.
Conflict of interest
The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Beuer, F., Edelhoff, D., Gernet, W. et al. Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs). Clin Oral Invest 13, 445–451 (2009). https://doi.org/10.1007/s00784-009-0249-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00784-009-0249-5