Background

Intramedullary reaming and nailing of long bones impairs the endosteal circulation, often causing necrosis of the inner region of the bone cortex. We hypothesized that compensatory hypertrophy of the periosteal microcirculation may develop in response to mechanical destruction of the endosteum, and that this may affect bone survival in these circumstances. In these studies, nailing was performed with materials that affect regeneration of the endosteum differently, and the effects on the tibial periosteal microvasculatory organization were examined.

Methods

In male Wistar rats, the right tibia was reamed and implanted with an inert titanium nail or a less osseointegrative polyethylene nail; the contralateral tibial endosteum was destroyed by reaming. Reaming without nailing or sham operation was performed on both extremities in two other groups of rats. Twelve weeks later, the anteromedial and anterolateral surfaces of the tibias were exposed by a microsurgical technique. The structural characteristics of the periosteal microcirculation (vessel density and distribution of vessel diameters) were determined by intravital videomicroscopy and computer-assisted analysis. The stability of the implants was assessed on the basis of grades 0–2 on a qualitative scale.

Results

Tibial reaming alone caused significant increases in overall blood vessel and capillary densities in the periosteum compared with those of the intact tibias. Implantation with a titanium nail resulted in firm embedding of the nail and caused changes in the periosteal vasculature similar to those after reaming alone. In contrast, implantation of a polyethylene nail was followed by the development of marked instability of the endomedullary implant and significant increases in the percentage of capillaries and the vessel density in the periosteum.

Conclusions

Destruction of the endosteal microcirculation per se brings about an increase in periosteal vascular density, which is further augmented if implantation is performed with a material which delays regeneration of the endosteal circulation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Macnab I, Dehoas WG. The role of periosteal blood supply in the healing of fractures of the tibia. Clin Orthop. 1974;105:27–33.

    PubMed  Google Scholar 

  2. Rhinelander FW, Phillips RS, Steel WM, Beer JC. Microangiography in bone healing. II. displaced closed fractures. J Bone Joint Surg (Am). 1968;50:643–62.

    CAS  Google Scholar 

  3. Trueta J, Cavadias AX. Vascular changes caused by the Küntscher type of nailing. J Bone Joint Surg (Br). 1955;37:492–505.

    Google Scholar 

  4. Rhinelander FW. The vascular response of bone to internal fixation. In: Browner BD, Edwards CC, editors. The science and practice of intramedullary nailing. Philadelphia: Lea & Febiger; 1987. p. 25.

    Google Scholar 

  5. Gustilo RB, Nelson GE, Hamel A, Moe JH. The effect of intramedullary nailing on the blood supply of the diaphysis of long bones in mature dogs. J Bone Joint Surg (Am). 1964;46:1362–4.

    Google Scholar 

  6. Danckwardt- Lillieström G, Lorenzi L, Olerud S. Intracortical circulation after intramedullary reaming with reduction of pressure in the medullary cavity: a microangiographic study on the rabbit tibia. J Bone Joint Surg (Am). 1970;52:1390–4.

    Google Scholar 

  7. Barron SE, Robb RA, Taylor WF, Kelly PJ. The effect of fixation with intramedullary rods and plates on fracture—site blood flow and bone remodeling in dogs. J Bone Joint Surg (Am). 1977;59:376–85.

    CAS  Google Scholar 

  8. White AA, Panjabi MM, Southwick WO. Effect of compression and cyclic loading on fracture healing—a quantitative biomechanical study. J Biomech. 1977;10:223–33.

    Article  Google Scholar 

  9. Pazzaglia UE. Periosteal and endosteal reaction to reaming and nailing: the possible role of revascularization on the endosteal anchorage of cementless stems. Biomaterials. 1996;17:1009–14.

    Article  PubMed  CAS  Google Scholar 

  10. Pazzaglia UE, Brossa F, Zatti G, Chiesa R, Andrini L. The relevance of hydroxyapatite and spongious titanium coatings in fixation of cementless stems. An experimental comparative study in rat femur employing histological and microangiographic techniques. Arch Orthop Trauma Surg. 1998;117:279–85.

    Article  PubMed  CAS  Google Scholar 

  11. Menger MD, Ruecker M, Wollmar B. Capillary dysfunction in striated muscle ischaemia/reperfusion: on the mechanisms of capillary “no-reflow”. Shock. 1997;8:2–7.

    Article  PubMed  CAS  Google Scholar 

  12. Wolfárd A, Császár J, Gera L, Perti A, Simonka JA, Balogh A, Boros M. Endothelin—a receptor antagonist treatment improves the periosteal microcirculation after hindlimb ischaemia and reperfusion in the rat. Microcirculation. 2002;9:471–6.

    PubMed  Google Scholar 

  13. Swiontkowsky MF, Tepic S, Perren SM, Moor R, Ganz R, Rahn BA. Laser Doppler flowmetry for bone blood flow measurement: correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow. J Orthop Res. 1986;4:362–71.

    Article  Google Scholar 

  14. ElMaraghy AW, Humeniuk B, Anderson GI, Schemitsch EH, Richards RR. Femoral bone blood flow after reaming and intramedullary canal preparation. A canine study using laser Doppler flowmetry. J Arthroplasty. 1999;14:220–6.

    Article  PubMed  CAS  Google Scholar 

  15. Ruecker M, Roesken F, Wollmar B, Menger MD. A novel approach for comparative study of periosteum, muscle, subcutis and skin microcirculation by intravital fluorescence microscopy. Microvasc Res. 1998;56(1):30–42.

    Article  Google Scholar 

  16. Reichert IL, McCarthy ID, Hughes SPF. The acute vascular response to intramedullary reaming. J Bone Joint Surg (Br). 1995;77:490–3.

    CAS  Google Scholar 

  17. Mueller CA, Schlegel V, Hoegel F, Eckhardt C, Schlegel U, Rahn BA, Pfister U, Suedkam NP. Cortical perfusion and local fat occlusion after intramedullary nailing of the ovine tibia—comparison of different surgical procedures. Injury. 2009;40:760–6.

    Article  PubMed  CAS  Google Scholar 

  18. Rhinelander FW, Nelson CL, Stewart RD, Stewart CL. Experimental reaming of the proximal femur and acrylic cement implantation. Clin Orthop. 1979;141:74–89.

    PubMed  Google Scholar 

  19. Linder L, Lindberg L, Carlsson A. Aseptic loosening of hip prostheses: a histological and enzyme histochemical study. Clin Orthop. 1983;175:93–104.

    PubMed  Google Scholar 

  20. Yamada H, Yoshihara Y, Henmi O, Morita M, Shiromoto Y, Kawano T, Kanaji A, Ando K, Nakagawa M, Kosaki N, Fukaya E. Cementless total hip replacement: past, present, and future. J Orthop Sci. 2009;14(2):228–41.

    Article  PubMed  Google Scholar 

  21. Koseki H, Matsumoto T, Ito S, Doukawa H, Enomoto H, Shindo H. Analysis of polyethylene particles isolated from periprosthetic tissue of loosened hip arthroplasty and comparison with radiographic appearance. J Orthop Sci. 2005;10(3):284–90.

    Article  PubMed  CAS  Google Scholar 

Download references

Acknowledgments

This work was supported by research grants TAMOP-4.2.1/B-09/1/KONV-2010-0005 and TAMOP-4.2.2-08/1-2008-0013.

Conflict of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Andrea Szabó.

About this article

Cite this article

Greksa, F., Tóth, K., Boros, M. et al. Periosteal microvascular reorganization after tibial reaming and intramedullary nailing in rats. J Orthop Sci 17, 477–483 (2012). https://doi.org/10.1007/s00776-012-0222-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00776-012-0222-z