Abstract
We have developed a lateral flow assay (LFA) for the detection of bisphenol A (BPA) in water samples. Antibody against BPA was labeled with gold nanoparticles, and these conjugates were used as the recognition probes for the construction of an LFA strip. The diameter of the gold nanoparticles, the amount of antibody, the pH of the buffer, and the categories of the conjugation pad were optimized. The resulting method has a (visual) detection limit of 5 ppb, and of 0.92 ppb if used in combination with professional software. This LFA displays excellent specificity and was applied to spiked water samples with satisfactory results.
Similar content being viewed by others
References
Bailin PD, Byrne M, Lewis S, Liroff R (2008) http://www.iehn.org/publications.reports.bpa.php
Alonso-Magdalena P, Ropero AB, Soriano S, Quesada I, Nadal A (2010) Bisphenol-A: a new diabetogenic factor. Hormones (Athens) 9:118–126
Liao CK, Kannan K (2011) Widespread occurrence of bisphenol a in paper and paper products: implications for human exposure. Environ Sci Technol 45:9372–9379
Lim DS, Kwack SJ, Kim KB, Kim HS, Lee BM (2009) Potential risk of bisphenol a migration from polycarbonate containers after heating, boiling, and microwaving. J Toxicol Environ Health A 72:1285–1291
Vandenberg LN, Maffini MV, Sonnenschein C, Rubin BS, Soto AM (2009) Bisphenol a and the great divide: a review of controversies in the field of endocrine disruption. Endocr Rev 30:75–95
Clarke BO, Smith SR (2011) Review of emerging organic contaminants in biosolids and assessment of international research priorities for the agricultural use of biosolids. Environ Int 37:226–247
Loganathan SN, Kannan K (2011) Occurrence of bisphenol A in indoor dust from two locations in the eastern United States and implications for human exposures. Arch Environ Contam Toxicol 61:68–73
Brody AL (2012) Making the healthy choice the easy choice. Food Technol 1:82–84
Hengstler JG, Foth H, Gebel T, Kramer PJ, Lilienblum W, Schweinfurth H, Völkel W, Wollin KM, Gundert-Remy U (2011) Critical evaluation of key evidence on the human health hazards of exposure to bisphenol A. Crit Rev Toxicol 41:263–291
Hardy ML, Banasik M, Stedeford T (2009) Toxicology and human health assessment of decabromodiphenyl. Crit Rev Toxicol 39:1–44
Vandenberg LN, Chahoud I, Heindel JJ, Padmanabhan V, Paumgartten FJR, Schoenfelder G (2010) Urinary, circulating, and tissue biomonitoring studies indicate widespread exposure to bisphenol A. Environ Health Perspect 118:1055–1070
Grumetto L, Montesano D, Seccia S, Albrizio S, Barbato F (2008) Determination of bisphenol A and bisphenol B residues in canned peeled tomatoes by reversed-phase liquid chromatography. J Agric Food Chem 56:10633–10637
Braunrath D, Podlipna S, Padlesak M, Cichna-Markl (2005) Determination of Bisphenol A in Canned Foods by Immunoaffinity Chromatography, HPLC, and Fluorescence Detection. J Agric Food Chem 53: 8911–8917
Brenn-Struckhofova Z, Cichna-Markl M (2006) Determination of bisphenol A in wine by sol–gel immunoaffinity chromatography. HPLC and fluorescence detection. Food Addit Contam 23:1227–1235
Nam SH, Seo YM, Kim MG (2010) Bisphenol A migration from polycarbonate baby bottle with repeated use. Chemosphere 79:949–952
del Olmo M, Zafra A, Navas NA, Vilchez JL (1999) Trace determination of phenol, bisphenol A and bisphenol A diglycidyl ether in mixtures by excitation fluorescence following micro liquid–liquid extraction using partial least squares regression. Analyst 124:385–390
Becerra V, Odermatt J (2012) Detection and quantification of traces of bisphenol A and bisphenol S in paper samples using analytical pyrolysis-GC/MS. Analyst 137:2250–2259
Calafat AM, Needham LL (2008) Factors affecting the evaluation of biomonitoring data for human exposure assessment. Int J Androl 31:139–143
Freymuth F, Quibriac M, Petitjean J, Amiel ML, Pothier P, Denis A, Duhamel JF (1986) Comparison of two new tests for rapid diagnosis of respiratory syncytial virus infections by enzyme-linked immunosorbent assay and immunofluorescence techniques. J Clin Microbiol 24:1013–1016
Zheng J, Zhang K, Zhao SQ (2008) Study on spectral and immune identification of artificial of Bishpenol A. Guang Pu Xue Yu Guang Pu Fen Xi 28:1583–1586
Mei ZL, Chu HQ, Chen W, Xue F, Liu J, Xu HN, Zhang R, Zheng L (2013) Ultrasensitive one-step rapid visual detection of bisphenol A in water samples by label-free aptasensor. Biosens Bioelectron 39:26–30
Wu JJ, Chu HQ, Mei ZL, Ye YK, Xue F, Liu J, Chen W, Zheng L (2012) Electrochemical aptasensor for the determination of bisphenol A in drinking water. Microchim Acta. doi:10.1007/s00604-012-0909-z
Martinez AW, Phillips ST, Whitesides GM (2010) Diagnostics for the developing world: microfluidic paper-based analytical devices. Anal Chem 82:3–10
Shim WB, Yang ZY, Kim JY, Choi JG, Je JH, Kang SJ, Kolosova AY, Eremin SA, Chung DH (2006) Immunochromatography using colloidal gold-antibody probe for the detection of atrazine in water samples. J Agric Food Chem 54:9728–9734
Ngom B, Guo YC, Wang XL, Bi DB (2010) Lateral-flow immunoassays for mycotoxins and phycotoxins: a review. Anal Bioanal Chem 397:1113–1135
Peng DP, Hu SS, Hua Y, Xiao YC, Li ZL, Wang X, Bi D (2007) Comparison of a new gold-immunochromatographic assay for the detection of antibodies against avian influenza virus with hemagglutination inhibition and agar gel immunodiffusion assays. J Veterinary Immunol Immunopathol 117:17–25
Mabey D, Peeling RW, Ustianowski A, Perkins MD (2004) Tropical infectious diseases: diagnostics for the developing world. Nature Reviews Microbiology 3:231–240
Leuvering JHW, Thal PJHM, Van der Waart M, Schuurs AHMW (1980) Sol particle immunoassay. J Immunoassay Immunochem 1:77–91
Lie PC, Liu J, Fang ZY, Dun BY, Zeng LW (2012) A lateral flow biosensor for detection of nucleic acids with high sensitivity and selectivity. Chem Commun 48:236–238
Fang ZY, Ge CC, Zhang WJ, Lie PC, Zeng LW (2011) A lateral flow biosensor for rapid detection of DNA-binding protein c-jun. Biosens Bioelectron 27:192–196
Liu GD, Mao X, Phillips JA, Xu H, Tan WH, Zeng LW (2009) Aptamer-nanoparticle strip biosensor for sensitive detection of cancer cells. Anal Chem 81:10013–10018
Liao JY, Li H (2010) Lateral flow immunodipstick for visual detection of aflatoxins B1 in flld using immune-nanoparticles composed of a silver core and a gold shell. Microchim Acta 171:289–295
Hartwell SK, Grudpan K (2010) Flow based immune/bioassay and trends in micro-immuno/biosensors. Microchim Acta 169:201–220
Xie HL, Ma M, Liu LQ, Chen W, Peng CF, Xu CL, Wang LB (2009) Development and validation of an immunochromatographic assay for rapid multi-residues detection of cephems in milk. Anal Chim Acta 634:129–133
Wang LB, Ma WW, Chen W, Liu LQ, Ma W, Zhu YY, Xu LG, Kuang H, Xu CL (2011) An aptamer-based chromatographic strip assay for sensitive toxin semi-quantitative detection. Biosens Bioelectron 26:3059–3062
Wang LB, Chen W, Ma WW, Liu LQ, Ma W, Zhao Y, Zhu YY, Xu LG, Kuang H, Xu CL (2011) Fluorescent strip sensor for rapid determination of toxins. Chem Commun 47:1574–1576
Acknowledgments
This work is financially supported by the Huangshan Young Scholar Fund of Hefei University of Technology (407–037025), the Science and Technology Research Project of General Administration of Quality Supervision, Inspection and Quarantine of P. R. China (201210127), the 12th Five Years Key Programs (2012BAK08B01, 2012BAK17B10, SS2012AA101001), and the Fundamental Research Funds for the Central Universities (2012HGCX0003).
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
ESM 1
(DOC 4128 kb)
Rights and permissions
About this article
Cite this article
Mei, Z., Deng, Y., Chu, H. et al. Immunochromatographic lateral flow strip for on-site detection of bisphenol A. Microchim Acta 180, 279–285 (2013). https://doi.org/10.1007/s00604-012-0930-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00604-012-0930-2