Abstract.
Sensors able to provide ‘yes’/‘no’ answers have become of interest in recent years, especially in the fields of environmental research and healthcare. We describe a procedure based on surface plasmon resonance imaging (SPRI) to investigate the interaction between mucin and anti-mucin antibody, and we outline the development of an alarm sensor for the protein mucin, whose high concentration in saliva, blood or tissue is related to illnesses such as gingivitis, peridontitis or even cancer. Anti-mucin gastric antibodies are immobilised onto a gold surface. The immobilisation is evaluated for neat gold chips and for polymer-modified gold surfaces. We found that two different pHs are required, one for the immobilisation of the antibodies on gold (pH 5.5) and a different one for optimal interaction between the sample and the antibody layer (pH 7.0). Finally, we briefly demonstrate the application of the sensor to real saliva samples, both mucin-less and mucin-containing, evaluating the potential of the sensor to discriminate between healthy and ill.
Similar content being viewed by others
References
D R Thévenot K Toth R A Durst G S Wilson (1999) ArticleTitleElectrochemical biosensors: recommended definitions and classifications. IUPAC© Pure Appl Chem 71 IssueID12 2333
S Cárdenas M Valcárcel (2005) ArticleTitleAnalytical features in qualitative analysis Trends Anal Chem 24 477 Occurrence Handle10.1016/j.trac.2005.03.006 Occurrence Handle1:CAS:528:DC%2BD2MXltFCmurk%3D
I Carlstedt J K Sheehan A P Corfield J T Gallagher (1985) ArticleTitleMucus glycoproteins: a gel of a problem Essays Biochem 20 40 Occurrence Handle3896779 Occurrence Handle1:CAS:528:DyaL2MXks1Krsrc%3D
S J Gendler et al. (1987) ArticleTitleCloning of partial cDNA encoding differentiation and tumor-associated mucin glycoproteins expressed by human mammary epithelium Proc Natl Acad Sci USA 84 6060 Occurrence Handle2888110 Occurrence Handle10.1073/pnas.84.17.6060 Occurrence Handle1987PNAS...84.6060G Occurrence Handle1:CAS:528:DyaL2sXls12rsL8%3D
M A Hollingsworth B J Swanson (2004) ArticleTitleMucins in cancer: protection and control of the cell surface Nature Revi 4 45 Occurrence Handle1:CAS:528:DC%2BD3sXpvVGnu7w%3D
A Moore Z Medarova A Potthast G Dai (2004) ArticleTitleIn vivo targeting of underglycosylated MUC-1 tumor antigen using a multimodal imaging probe Cancer Res 64 1821 Occurrence Handle14996745 Occurrence Handle10.1158/0008-5472.CAN-03-3230 Occurrence Handle1:CAS:528:DC%2BD2cXhslersr8%3D
E Gorodkiewicz A Fernández-González A Akkoyun G Steiner R Salzer (2005) ArticleTitleSystematic evaluation of a surface plasmon resonance imaging biochip reader: study of golf surface modifications Chem Anal 50 103 Occurrence Handle1:CAS:528:DC%2BD2MXivFGgsbw%3D
C Boozer Q Yu S Chen C-Y Lee J Homola S S Yee S Jiang (2003) ArticleTitleSurface functionalization for self-referencing surface plasmon resonance (SPR) biosensors by multi-step self-assembly Sens Actuat B: Chem 90 22 Occurrence Handle10.1016/S0925-4005(03)00017-0 Occurrence Handle1:CAS:528:DC%2BD3sXis12jsrc%3D
E A Smith W D Thomas L L Kiessling R M Corn (2003) ArticleTitleSurface plasmon resonance imaging studies of protein-carbohydrate interactions J Am Chem Soc 125 IssueID20 6140 Occurrence Handle12785845 Occurrence Handle10.1021/ja034165u Occurrence Handle1:CAS:528:DC%2BD3sXjtlWhsLw%3D
G J Wegner H J Lee R M Corn (2002) ArticleTitleCharacterization and optimisation of peptide arrays for the study of epitope-antibody interactions using surface plasmon resonance imaging Anal Chem 74 5161 Occurrence Handle12403566 Occurrence Handle10.1021/ac025922u Occurrence Handle1:CAS:528:DC%2BD38XmvFKkt7g%3D
N K Chaki K Vijayamohanan (2002) ArticleTitleSelf-assembled monolayers as a tunable platform for biosensor applications Biosens Bioelec 17 1 Occurrence Handle10.1016/S0956-5663(01)00277-9 Occurrence Handle1:CAS:528:DC%2BD3MXptVSmtL8%3D
G J Wegner H J Lee G Marriott R M Corn (2003) ArticleTitleFabrication of histidine-tagged fusion protein arrays for surface plasmon resonance imaging studies of protein–protein and protein–DNA interactions Anal Chem 75 4740 Occurrence Handle14674449 Occurrence Handle10.1021/ac0344438 Occurrence Handle1:CAS:528:DC%2BD3sXlvVyks74%3D
V M Mirsky M Riepl O S Wolfbeis (1997) ArticleTitleCapacitive monitoring of protein immobilization and antigen-antibody reactions on monomolecular alkylthiol films on gold electrodes Biosens Bioelec 12 977 Occurrence Handle10.1016/S0956-5663(97)00053-5 Occurrence Handle1:CAS:528:DyaK1cXkvVensw%3D%3D
F Darain S-U Park Y-B Shim (2003) ArticleTitleDisposable amperometric immunosensor system for rabbit IgG using a conducting polymer modified screen-printed electrode Biosens Bioelec 18 IssueID5–6 773 Occurrence Handle10.1016/S0956-5663(03)00004-6 Occurrence Handle1:CAS:528:DC%2BD3sXivV2kt70%3D
N F Starodub L V Pirogova A Demchenko A V Nabok (2005) ArticleTitleAntibody immobilisation on the metal and silicon surfaces. The use of self-assembled layers and specific receptors Bioelectrochem 66 IssueID1–2 111 Occurrence Handle10.1016/j.bioelechem.2004.04.007 Occurrence Handle1:CAS:528:DC%2BD2MXjtF2hsLo%3D
Shen G-Y, Wang H, Deng T, Shen G-L, Yu R-Q (2005) A novel piezoelectric immunosensor for detection of carcinoembryonic antigen. Talanta (in press)
Y-M Bae B-K Oh W Lee W-H Lee J-W Choi (2004) ArticleTitleDetection of insulin-antibody binding on a solid surface using imaging ellipsometry Biosens Bioelec 20 IssueID4 895 Occurrence Handle1:CAS:528:DC%2BD2cXpt1WhtLs%3D Occurrence Handle10.1016/j.bios.2004.03.032
G Steiner (2004) ArticleTitleSurface plasmon resonance imaging Anal Bioanal Chem 379 IssueID3 328 Occurrence Handle15127177 Occurrence Handle10.1007/s00216-004-2636-8 Occurrence Handle1:CAS:528:DC%2BD2cXktlWqsb0%3D Occurrence Handle2086323
K L Brogan K N Wolfe P A Jones M H Schoenfisch (2003) ArticleTitleDirect oriented immobilization of F(ab’) antibody fragments on gold Anal Chim Acta 496 73 Occurrence Handle10.1016/S0003-2670(03)00991-7 Occurrence Handle1:CAS:528:DC%2BD3sXos12kt7o%3D
M Kim S O Jung K Park E J Jeong H A Joung T H Kim D W Seol B H Chung (2005) ArticleTitleDetection of bax protein conformational change using a surface plasmon resonance imaging-based antibody chip Biochem Biophys Res Commun 338 1834 Occurrence Handle16288712 Occurrence Handle10.1016/j.bbrc.2005.10.155 Occurrence Handle1:CAS:528:DC%2BD2MXht1Ggu77I
M Kyo K Usui-Aoki H Koga (2005) ArticleTitleLabel-free detection of proteins in crude cell lysate with antibody arrays by a surface plasmon resonance imaging technique Anal Chem 77 7115 Occurrence Handle16285656 Occurrence Handle10.1021/ac050884a Occurrence Handle1:CAS:528:DC%2BD2MXhtFWgtr3L
G J Wegner H J Lee R M Corn (2002) ArticleTitleCharacterization and optimization of peptide arrays for the study of epitope-antibody interactions using surface plasmon resonance imaging Anal Chem 74 5161 Occurrence Handle12403566 Occurrence Handle10.1021/ac025922u Occurrence Handle1:CAS:528:DC%2BD38XmvFKkt7g%3D
G J Wegner H J Lee G Marriott R M Corn (2003) ArticleTitleFabrication of histidine-tagged fusion protein arrays for surface plasmon resonance imaging studies of protein–protein and protein–DNA interactions Anal Chem 75 4740 Occurrence Handle14674449 Occurrence Handle10.1021/ac0344438 Occurrence Handle1:CAS:528:DC%2BD3sXlvVyks74%3D
T T Goodrich A W Wark R M Corn H J Lee (2006) ArticleTitleSurface plasmon resonance imaging measurements of protein interactions with biopolymer microarrays Meth Mol Biol 328 113 Occurrence Handle1:CAS:528:DC%2BD28Xjt12gt74%3D
Z Sun Y He J Guo (2006) ArticleTitleSurface plasmon resonance sensor based on polarization interferometry and angle modulation Appl Opt 45 3071 Occurrence Handle16639455 Occurrence Handle10.1364/AO.45.003071 Occurrence Handle2006ApOpt..45.3071S
I H El-Sayed X Huang M A El-Sayed (2005) ArticleTitleSurface plasmon resonance scattering and absorption of anti-EGFR antibody conjugated gold nanoparticles in cancer diagnostics: applications in oral cancer Nano Lett 5 829 Occurrence Handle15884879 Occurrence Handle10.1021/nl050074e Occurrence Handle1:CAS:528:DC%2BD2MXjt1SmtLg%3D
V Kanda J K Kariuki D J Harrison M T McDermott (2004) ArticleTitleLabel-free reading of microarray-based immunoassays with surface plasmon resonance imaging Anal Chem 76 7257 Occurrence Handle15595867 Occurrence Handle10.1021/ac049318q Occurrence Handle1:CAS:528:DC%2BD2cXpslentrg%3D
E Maillart K Brengel-Pesce D Capela A Roget T Livache M Canva Y Levy T Soussi (2004) ArticleTitleVersatile analysis of multiple macromolecular interactions by SPR imaging: application to p53 and DNA interaction Oncogene 23 5543 Occurrence Handle15184889 Occurrence Handle10.1038/sj.onc.1207639 Occurrence Handle1:CAS:528:DC%2BD2cXls1Cjsbg%3D
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Fernández-González, A., Rychłowska, J., Badía, R. et al. SPR imaging as a tool for detecting mucin – anti-mucin interaction. Outline of the development of a sensor for near-patient testing for mucin. Microchim Acta 158, 219–225 (2007). https://doi.org/10.1007/s00604-006-0698-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00604-006-0698-3