Abstract
Bioresorbable devices are commonly used in traumatology. The biomechanical stability of these materials has improved in the past decade, and they have proven to be biologically non-hazardous, while their main advantage is that their use avoids reintervention for removal of the device. A prospective monocentric study was conducted: 24 patients presenting with a fracture that was amenable to osteosynthesis by small-diameter screws were included. These comprised ten tibial spine fractures, four osteochondritis dissecans of the distal femur, eight fractures of the medial epicondyle of the distal humerus, and two distal tibial apophyseal fractures. One or more screws were used that were made of a copolymer of poly-l-lactide-poly-d-lactide acid and trimethylene carbonate with a diameter of 2.8 mm. All patients were immobilized with a cast. Clinical and radiographic monitoring was conducted every month. The entire follow-up protocol had a duration of 24 months. One patient with osteochondritis dissecans presented with joint effusion. Joint stiffness at the time of cast removal resolved completely after 4 months, except for with three children (one epicondyle fracture, two tibial spine fractures). No subjective or objective instability could be detected by clinical examination. Radiographic follow-up revealed no secondary displacement, and all of the fractures had healed. No osteolysis was seen around the screws. No growth disturbances were noticed. Bioresorbable materials thus appear to be a suitable alternative approach for certain pediatric fractures. Their use resulted in outcomes similar to traditional techniques in terms of functional properties and bone healing. Although initial costs are presumably slightly higher, by avoiding a removal operation the total financial burden is most likely reduced.
Level of evidence
III.
Similar content being viewed by others
References
Gogolewski S (2000) Bioresorbable polymers in trauma and bone surgery. Injury 31(Suppl 4):28–32
Ashammakhi N, Renier D, Arnaud E, Marchac D, Ninkovic M, Donaway D et al (2004) Successful use of biosorb osteofixation devices in 165 cranial and maxillofacial cases: a multicenter report. J Craniofac Surg 15:692–701
Cheung LK, Chow LK, Chiu WK (2004) A randomized controlled trial of resorbable versus titanium fixation for orthognathic surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 98:386–397
Eppley BL (2007) Bioabsorbable plate and screw fixation in orthognathic surgery. J Craniofac Surg 18:818–825
Eppley BL (2005) Use of resorbable plates and screws in pediatric facial fractures. J Oral Maxillofac Surg 63:385–391
Eppley BL, Morales L, Wood R, Pensler J, Goldstein J, Havlik RJ et al (2004) Resorbable PLLA-PGA plate and screw fixation in pediatric craniofacial surgery: clinical experience in 1883 patients. Plast Reconstr Surg 114:850–856
Bucholz RW, Henry S, Henley MB (1994) Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J Bone Joint Surg Am 76:319–324
Hovis WD, Kaiser BW, Watson JT, Bucholz RW (2002) Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation. J Bone Joint Surg Am 84-A:26–31
Kankare J, Partio EK, Hirvensalo E, Böstman O, Rokkanen P (1996) Biodegradable self-reinforced polyglycolide screws and rods in the fixation of displaced malleolar fractures in the elderly. A comparison with metallic implants. Ann Chir Gynaecol 85:263–270
Sinisaari IP, Lüthje PMJ, Mikkonen RHM (2002) Ruptured tibio-fibular syndesmosis: comparison study of metallic to bioabsorbable fixation. Foot Ankle Int 23:744–748
Thordarson DB, Samuelson M, Shepherd LE, Merkle PF, Lee J (2001) Bioabsorbable versus stainless steel screw fixation of the syndesmosis in pronation-lateral rotation ankle fractures: a prospective randomized trial. Foot Ankle Int 22:335–338
Nieminen T, Rantala I, Hiidenheimo I, Keränen J, Kainulainen H, Wuolijoki E et al (2008) Degradative and mechanical properties of a novel resorbable plating system during a 3-year follow-up in vivo and in vitro. J Mater Sci Mater Med 19:1155–1163
Meyers MH, McKeever FM (1970) Fracture of the intercondylar eminence of the tibia. J Bone Joint Surg Am 52:1677–1684
Meyers MH, McKeever FM (1959) Fracture of the intercondylar eminence of the tibia. J Bone Joint Surg Am 41-A:209–222
Mavrogenis AF, Kanellopoulos AD, Nomikos GN, Papagelopoulos PJ, Soucacos PN (2009) Early experience with biodegradable implants in pediatric patients. Clin Orthop Relat Res 467:1591–1598
Kukk A, Nurmi JT (2009) A retrospective follow-up of ankle fracture patients treated with a biodegradable plate and screws. Foot Ankle Surg 15:192–197
Casteleyn PP, Handelberg F, Haentjens P (1992) Biodegradable rods versus Kirschner wire fixation of wrist fractures. A randomised trial. J Bone Joint Surg Br 74:858–861
Fraser RK, Cole WG (1992) Osteolysis after biodegradable pin fixation of fractures in children. J Bone Joint Surg Br 74:929–930
Rokkanen P, Böstman O, Vainionpää S, Makela EA, Hirvensalo E, Partio EK et al (1996) Absorbable devices in the fixation of fractures. J Trauma 40:S123–S127
Eitenmüller J, David A, Pommer A, Muhr G (1996) Surgical treatment of ankle joint fractures with biodegradable screws and plates of poly-l-lactide. Chirurg 67:413–418
Böstman OM, Pihlajamäki HK (2000) Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop Relat Res 371:216–227
Raney EM, Freccero DM, Dolan LA, Lighter DE, Fillman RR, Chambers HG (2008) Evidence-based analysis of removal of orthopaedic implants in the pediatric population. J Pediatr Orthop 28:701–704
Böstman OM (1996) Metallic or absorbable fracture fixation devices. A cost minimization analysis. Clin Orthop Relat Res 329:233–239
Louahem DM, Bourelle S, Buscayret F, Mazeau P, Kelly P, Dimeglio A et al (2010) Displaced medial epicondyle fractures of the humerus: surgical treatment and results. A report of 139 cases. Arch Orthop Trauma Surg 130:649–655
Casalonga A, Bourelle S, Chalencon F, De Oliviera L, Gautheron V, Cottalorda J (2010) Tibial intercondylar eminence fractures in children: the long-term perspective. Orthop Traumatol Surg Res 96:525–530
Tuompo P, Arvela V, Partio EK, Rokkanen P (1997) Osteochondritis dissecans of the knee fixed with biodegradable self-reinforced polyglycolide and polylactide rods in 24 patients. Int Orthop 21:355–360
Larsen MW, Pietrzak WS, DeLee JC (2005) Fixation of osteochondritis dissecans lesions using poly(l-lactic acid)/poly(glycolic acid) copolymer bioabsorbable screws. Am J Sports Med 33:68–76
Barfod G, Svendsen RN (1992) Synovitis of the knee after intraarticular fracture fixation with Biofix. Report of two cases. Acta Orthop Scand 63:680–681
Fridén T, Rydholm U (1992) Severe aseptic synovitis of the knee after biodegradable internal fixation. A case report. Acta Orthop Scand 63:94–97
Lefort G, Moyen B, Beaufils P, de Billy B, Breda R, Cadilhac C et al (2006) Osteochondritis dissecans of the femoral condyles: report of 892 cases. Rev Chir Orthop Reparatrice Appar Mot 92:2S97–92S141
Conflict of interest
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Poircuitte, J.M., Popkov, P., Huber, D.H. et al. Resorbable osteosynthetic devices in pediatric traumatology: a prospective series of 24 cases. Eur J Orthop Surg Traumatol 25, 997–1004 (2015). https://doi.org/10.1007/s00590-015-1656-8
Received:
Accepted:
Published:
Issue Date: