Abstract
Object
This study was intended to objectively demonstrate the effect of interspinous implantation through preoperative and postoperative radiological analyses in degenerative lumbar spinal stenosis.
Methods
This study included 20 segments of 14 cases that had been diagnosed as spinal stenosis through physical and radiological findings and had interspinous implantation (X‐stop®). On simple radiography, height and width of the intervertebral foramen, height of the anterior and posterior intervertebral disks, and interbody angle were measured. On magnetic resonance imaging (MRI), the intervertebral foramen and intradural areas were also measured. Changes in preoperative and postoperative measurements were compared, and correlation between radiological indicators was identified. Clinical evaluation was done using visual analog scale (VAS) and Oswestry disability index (ODI) scores. The relationship between the clinical outcomes and radiological changes was also evaluated.
Results
The comparison of preoperative and postoperative radiological measurements showed significant changes in height and width of the intervertebral foramen, and interbody angle on simple radiography, and in height of the intervertebral foramen on MRI. Regarding correlation between radiological indicators, there was correlation between height of the intervertebral foramen on simple radiography and area of the intervertebral foramen on MRI, and between the intervertebral foramen and intradural areas on MRI. For correlation between the clinical improvement level and the changes in radiological parameters, VAS correlated with intervertebral foramen height on simple radiography and increased area of the intervertebral foramen on MRI. However, for ODI, there was no factor showing significant correlation.
Conclusions
In patients with degenerative spinal stenosis showing neurogenic claudication, interspinous implantation was more effective in increasing the height and area of the intervertebral foramen than in increasing intradural area, and the short‐term clinical results were promising.
Similar content being viewed by others
References
Verbiest H (1954) A radicular syndrome from developmental narrowing of the lumbar vertebral canal. J Bone Joint Surg Br 36:230–237
Chung SS, Lee CS, Kim SH (2000) Effect of low back posture on the morphology of the spinal canal. Skeletal Radiol 29:217–223
Lindsay DP, Swanson KE, Fuchs P, Hsu KY, Zucherman JF, Yerby S (2003) The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine. Spine 28:2192–2197
Zucherman JF, Hsu KY, Hartjen CA et al (2004) A prospective randomized multi-center study for the treatment of lumbar spinal stenosis with the X STOP interspinous implant: 1 year results. Eur Spine J 13:22–31
Zucherman JF, Hsu KY, Hartjen CA et al (2005) Multicenter, prospective randomized trial evaluating the XSTOP interspinous process decompression system for the treatment of neurogenic intermittent claudication. Spine 30:1351–1358
White AA, Panjabi MM (1990) Clinical biomechanics of the spine, 2nd edn. JB Lippincott Co, Philadelphia, pp 23–45
Sobottke R, Schlüter-Brust K, Kaulhausen T et al (2009) Interspinous implants (X Stop, Wallis, Diam) for the treatment of LSS: is there a correlation between radiological parameters and clinical outcome? Eur Spine J 18:1494–1503
Schonstrom N, Lindahl S, Willén J et al (1989) Dynamic changes in the dimensions of the lumbar spinal canal: an experimental study in vitro. J Orthop Res 7:115–121
Infusa A, An HS, Lim TH et al (1996) Anatomic changes of the spinal canal and intervertebral foramen associated with flexion-extension movement. Spine 21:2412–2420
Schmid MR, Stucki G, Duewell S et al (1999) Changes in the cross-sectional measurements of the spinal canal and intervertebral foramina as a function of body position: in vivo studies on an open-configuration MR system. AJR Am J Roentgenol 172:1095–1102
Kondrashov DG, Hannibal M, Hsu KY, Zucherman JF (2006) Interspinous process decompression with the X-STOP device for lumbar spinal stenosis: a 4-year follow-up study. J Spinal Disord Tech 19:323–327
Barbagallo GM, Olindo G, Corbino L, Albanese V (2009) Analysis of complications in patients treated with the X-Stop Interspinous Process Decompression System: proposal for a novel anatomic scoring system for patient selection and review of the literature. Neurosurgery 65:111–119
Siddiqui M, Karadimas E, Nicol M, Smith FW, Wardlaw D (2006) Influence of X Stop on neural foramina and spinal canal area in spinal stenosis. Spine 31:2958–2962 (Phila Pa 1976)
Conflict of interest
The authors state that there are no conflicts of interest. No benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of the article.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kim, HY., Choi, BW. Change of radiological parameters after interspinous implantation (X-stop®) in degenerative spinal stenosis. Eur J Orthop Surg Traumatol 23, 281–285 (2013). https://doi.org/10.1007/s00590-012-0986-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00590-012-0986-z