Abstract
Purpose
A multi-detector computed tomography (CT) imaging system with a mobile scanner gantry in the operating room can provide intraoperative reconstructed images with a high resolution. We devised a technique for cervical pedicle screw (CPS) placement using the mobile CT system and evaluated the accuracy of this technique.
Methods
Forty-eight patients who underwent cervical fixation using CPSs were prospectively enrolled in this study. Initial pedicle probing was performed approximately to the depth of the posterior aspect of the vertebral body using fluoroscopic lateral view, and a marking pin was put in place. Intraoperative CT images were obtained to confirm whether the position of the marking pin was accurate. After adequate modification of the trajectory was performed, an appropriately sized CPS was inserted. The accuracy of the CPS was evaluated using postoperative reconstructed CT images, and compared with a historical control group of 22 patients (CPS insertion using only fluoroscopy).
Results
A total of 193 CPSs were inserted. Intraoperative CT images demonstrated that 12.4 % of the initial probings were not accurate, and modification of the trajectory was required. On postoperative CT, 92.7 % of the CPSs were found to be placed accurately: the accuracy was significantly higher than the control group (80.9 %). In the cases using intraoperative CT images, only 1.0 % of the screws were judged to show grade 2 screw misplacement; no neurovascular complications associated with screw placement were observed.
Conclusions
The technique of CPS placement using mobile CT was shown to be safe and effective in preventing catastrophic complications associated with CPS insertion.
Similar content being viewed by others
References
Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine 25:962–969
Kotil K, Akcetin MA, Savas Y (2012) Neurovascular complications of cervical pedicle screw fixation. J Clin Neurosci 19:546–551. doi:10.1016/j.jocn.2011.05.041
Karaikovic EE, Kunakornsawat S, Daubs MD, Madsen TW, Gaines RW Jr (2000) Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization. J Spinal Disord 13:63–72
Chazono M, Soshi S, Inoue T, Kida Y, Ushiku C (2006) Anatomical considerations for cervical pedicle screw insertion: the use of multiplanar computerized tomography reconstruction measurements. J Neurosurg Spine 4:472–477. doi:10.3171/spi.2006.4.6.472
Kanna PR, Shetty AP, Rajasekaran S (2011) Anatomical feasibility of pediatric cervical pedicle screw insertion by computed tomographic morphometric evaluation of 376 pediatric cervical pedicles. Spine (Phila Pa 1976) 36:1297–1304. doi:10.1097/BRS.0b013e3181fb3c17
Yukawa Y, Kato F, Yoshihara H, Yanase M, Ito K (2006) Cervical pedicle screw fixation in 100 cases of unstable cervical injuries: pedicle axis views obtained using fluoroscopy. J Neurosurg Spine 5:488–493. doi:10.3171/spi.2006.5.6.488
Yoshimoto H, Sato S, Hyakumachi T, Yanagibashi Y, Kanno T, Masuda T (2009) Clinical accuracy of cervical pedicle screw insertion using lateral fluoroscopy: a radiographic analysis of the learning curve. Eur Spine J 18:1326–1334. doi:10.1007/s00586-009-1109-3
Ishikawa Y, Kanemura T, Yoshida G, Ito Z, Muramoto A, Ohno S (2010) Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement. J Neurosurg Spine 13:606–611. doi:10.3171/2010.5.SPINE09993
Hojo Y, Ito M, Suda K, Oda I, Yoshimoto H, Abumi K (2014) A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws. Eur Spine J 23:2166–2174. doi:10.1007/s00586-014-3470-0
Lu S, Xu YQ, Lu WW, Ni GX, Li YB, Shi JH, Li DP, Chen GP, Chen YB, Zhang YZ (2009) A novel patient-specific navigational template for cervical pedicle screw placement. Spine (Phila Pa 1976) 34:E959–E966. doi:10.1097/BRS.0b013e3181c09985
Kaneyama S, Sugawara T, Sumi M (2015) Safe and accurate mid-cervical pedicle Screw insertion procedure with the patient-specific SCREW guide template system. Spine (Phila Pa 1976). doi:10.1097/BRS.0000000000000772
Richter M, Cakir B, Schmidt R (2005) Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine (Phila Pa 1976) 30:2280–2287. doi:10.1097/01.brs.0000182275.31425.cd
Ishikawa Y, Kanemura T, Yoshida G, Matsumoto A, Ito Z, Tauchi R, Muramoto A, Ohno S, Nishimura Y (2011) Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion. J Neurosurg Spine 15:472–478. doi:10.3171/2011.6.SPINE10809
Uehara M, Takahashi J, Ikegami S, Mukaiyama K, Kuraishi S, Shimizu M, Futatsugi T, Ogihara N, Hashidate H, Hirabayashi H, Kato H (2014) Screw perforation features in 129 consecutive patients performed computer-guided cervical pedicle screw insertion. Eur Spine J 23:2189–2195. doi:10.1007/s00586-014-3502-9
Abumi K, Shono Y, Taneichi H, Ito M, Kaneda K (1999) Correction of cervical kyphosis using pedicle screw fixation systems. Spine (Phila Pa 1976) 24:2389–2396
Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99:257–263
Ebraheim NA, Xu R, Knight T, Yeasting RA (1997) Morphometric evaluation of lower cervical pedicle and its projection. Spine (Phila Pa 1976) 22:1–6
Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws Anatomic feasibility and biomechanical comparison. Spine (Phila Pa 1976) 22:977–982
Neo M, Sakamoto T, Fujibayashi S, Nakamura T (2005) The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine (Phila Pa 1976) 30:2800–2805. doi:10.1097/01.brs.0000192297.07709.5d
Bydon M, Xu R, Amin AG, Macki M, Kaloostian P, Sciubba DM, Wolinsky JP, Bydon A, Gokaslan ZL, Witham TF (2014) Safety and efficacy of pedicle screw placement using intraoperative computed tomography: consecutive series of 1148 pedicle screws. J Neurosurg Spine 21:320–328. doi:10.3171/2014.5.SPINE13567
Scheufler KM, Franke J, Eckardt A, Dohmen H (2011) Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: thoracolumbar spine. Neurosurgery 69:1307–1316. doi:10.1227/NEU.0b013e31822ba190
Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247–255. doi:10.1007/s00586-011-2011-3
Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2000) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13:218–224
Holly LT (2006) Image-guided spinal surgery. Int J Med Robot 2:7–15. doi:10.1002/rcs.69
Lee SH, Kim KT, Abumi K, Suk KS, Lee JH, Park KJ (2012) Cervical pedicle screw placement using the “key slot technique”: the feasibility and learning curve. J Spinal Disord Tech 25:415–421. doi:10.1097/BSD.0b013e3182309657
Acknowledgments
This work was supported by Japanese Health Labour Sciences Research Grant. We thank Renpei Matsumoto MD, and Shuta Ushio MD for their imaging works.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
None.
Rights and permissions
About this article
Cite this article
Yoshii, T., Hirai, T., Sakai, K. et al. Cervical pedicle screw placement using intraoperative computed tomography imaging with a mobile scanner gantry. Eur Spine J 25, 1690–1697 (2016). https://doi.org/10.1007/s00586-016-4508-2
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00586-016-4508-2