Abstract
Purpose
This study investigated whether pedicle screws medially misplaced into the spinal canal without neurological complications should be removed or not.
Methods
A total of 86 patients with scoliosis that underwent spinal fusion using 988 pedicle screws were retrospectively reviewed after a minimum follow-up of 2 years. The inclusion criteria were: (1) patients without outstanding problems during the insertion of pedicle screws, (2) patients without neurological deficits either intraoperatively or postoperatively, and (3) patients that had all implants removed after bone union upon the request of the patient. Medial perforations were evaluated using immediate postoperative helical CT images and classified into three grades: grade 1 (0–2 mm), grade 2 (2–4 mm), and grade 3 (over 4 mm). All unexpected events were recorded at the time of removal.
Results
CT images obtained 2 years postoperatively exhibited neither loosening of screws nor pseudoarthrosis in all patients. CSF leakage from screw holes were recognized in 3 of 87 medially misplaced screws (3.4 %). There was no CSF leakage in grade 1 (35 screws), one CSF leakage (2.5 %) in grade 2 (40 screws), and two (16.7 %) in grade 3 (12 screws). No neurological abnormalities occurred either intraoperatively or postoperatively.
Conclusion
This study indicated that screws medially misplaced at a distance greater than 2 mm, especially 4 mm, may be a cause of negative effects on the neural structure and should be removed during the early phase of the postoperative period, even among patients without postoperative neurological abnormalities.
Similar content being viewed by others
References
Papin P, Arlet V, Marchesi D, Rosenblatt B, Aebi M (1999) Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J 8:156–160
Suk SI, Kim WJ, Lee SM, Kim JH, Chung ER (2001) Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine 26:2049–2057
Albayram S, Ulu MO, Hanimoglu H, Kaynar MY, Hanci M (2008) Intracranial hypotension following scoliosis surgery: dural penetration of a thoracic pedicle screw. Eur Spine J 17(Suppl 2):S347–S350
Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew D (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29:333–342
Choi JB, Han JO, Jeong JW (2001) False aneurysm of the thoracic aorta associated with an aorto-chest wall fistula after spinal instrumentation. J Trauma 50:140–143
Wegener B, Birkenmaier C, Fottner A, Jansson V, Durr HR (2008) Delayed perforation of the aorta by a thoracic pedicle screw. Eur Spine J 17(Suppl 2):S351–S354
Mac-Thiong JM, Parent S, Poitras B, Joncas J, Hubert L (2013) Neurological outcome and management of pedicle screws misplaced totally within the spinal canal. Spine 38:229–237
Reidy DP, Houlden D, Nolan PC, Kim M, Finkelstein JA (2001) Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws. J Bone Joint Surg Am 83:1009–1014
Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA, Cotler JM (1995) Placement of pedicle screws in the thoracic spine. I: Morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 77:1193–1199
Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14
Liljenqvist U, Lepsien U, Hackenberg L, Niemeyer T, Halm H (2002) Comparative analysis of pedicle screw and hook instrumentation in posterior correction and fusion of idiopathic thoracic scoliosis. Eur Spine J 11:336–343
Liljenqvist UR, Allkemper T, Hackenberg L, Link TM, Steinbeck J, Harm HF (2002) Analysis of vertebral morphology in idiopathic scoliosis with use of magnetic resonance imaging and multiplanar reconstruction. J Bone Joint Surg Am 84:359–368
Di Silvestre M, Parisini P, Lolli F, Bakaloudis G (2007) Complications of thoracic pedicle screws in scoliosis treatment. Spine 32:1655–1661
Wang JC, Bohlman HH, Riew KD (1998) Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am 80:1728–1732
Acknowledgments
No funds were received in support of this work. No benefits in any form have been or will be received from commercial party related directly or indirectly to the subject of this manuscript.
Conflict of interest
The authors have no financial conflicts of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sugawara, R., Tsuji, T., Saito, T. et al. Medially misplaced pedicle screws in patients without neurological deficits following scoliosis surgery: to observe or to remove?. Eur Spine J 24, 1450–1456 (2015). https://doi.org/10.1007/s00586-015-3860-y
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00586-015-3860-y