Abstract
Touch mode capacitive pressure sensor offer better performance in many applications than other devices. In touch mode operation of a capacitive pressure sensor the diaphragm touches the bottom of the substrate. Due to this several advantages such as near-linear output characteristics, large over range pressure and robust nature of the device was observed, which made it possible to withstand harsh industrial environment. To obtain better performance on the existing single sided touch mode capacitive pressure sensor (STMCPS) a double sided one has been proposed. In double sided touch mode capacitive pressure sensor (DTMCPS) an additional notch was etched at bottom of the substrate. So far in literature the advantage of DTMCPS over single sided has been discussed i.e. linear output characteristics, large over range protection and robust structure but no work is present which elaborates step by step calculation of performance parameters such as capacitance and sensitivity. Here we have completely derived the underlying expressions for performance parameters. The next step has been to validate our claims of higher sensitivity of this structure over single sided one. So MATLAB has been introduced and interpretations have been made. It has been proved that for the same size and touch point pressure as used in STMCPS the linear range of operation can be extended and the sensitivity can be enhanced for DTMCPS. Furthermore by addition of a notch the reliability of the sensor is also improved.
Similar content being viewed by others
References
Daigle M et al (2007) An analytical solution to circular touch mode capacitor. IEEE Sens J 7(4):502–505
Eswaran P, Malarvizhi S (2013) MEMS capacitive pressure sensors: a review on recent development and prospective. Int J Eng Technol 5:2734–2746
Gaopan Xu et al (2001) A surface micro machined double sided touch mode capacitive pressure sensor. SPIE 4601:25–30
Gupta A et al (2003) A capacitive pressure sensor for MEMS. SPIE 5062:450–454
Jindal SK et al (2015) A complete analytical model for clamped edge circular diaphragm non-touch and touch mode capacitive pressure sensor. In: Microsystem Technologies. Springer, Berlin. doi:10.1007/s00542-015-2475-x
Jindal SK, Raghuwanshi SK (2015) A complete analytical model for circular diaphragm pressure sensor for freely supported edge. Microsyst Technol Springer 21(5):1073–1079
Ko WH, Wang Q (1999) Touch mode capacitive pressure sensors. Sens Actuators A Phys 75:242–251
Lee YH, Choi B (2015) Theoretical and experimental investigation of the trapped air effect on air sealed capacitive pressure sensor. Sens Actuators, A 221:104–114
Lee MK et al (2013) Numerical analysis of touch mode capacitive pressure sensor using graphical user interface. DEIT springer 1:371–377
Lv H et al (2008) A touch mode capacitive pressure sensor with long linear range and high sensitivity In: Proceedings of the 3rd IEEE Int. Conf. on Nano/Micro Engineered and Molecular Systems, pp 796–800
Meng G, Ko WH (1999) Modelling of circular diaphragm and spread sheet solution programming for touch mode capacitive sensors. Sens Actuators A Phys 75:45–52
Saleh S et al (2006) Modelling of sensitivity of fabricated capacitive pressure sensor. In: IEEE Proc, pp. 3166–3169
Timoshenko SP (1959) Nonlinear problems in bending of circular plates, theory of plates and shells. Maple press, New York
Timoshenko SP, Kreiger S (1959) Theory of plates and shells, 2nd edn. McGraw Hill, New York
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jindal, S.K., Raghuwanshi, S.K. Capacitance and sensitivity calculation of double touch mode capacitive pressure sensor: theoretical modelling and simulation. Microsyst Technol 23, 135–142 (2017). https://doi.org/10.1007/s00542-015-2696-z
Received:
Accepted:
Published:
Issue Date: