Abstract
Conductivity is an important issue of water quality detection. Although there are a number of microfluidic liquid conductivity sensors, most of them were difficult to fabricate and required cleanroom facilities, which significantly increased the cost of sensors. Here, we presented a novel liquid conductivity sensor that was built on interdigitated copper electrodes. Microscale sensor electrodes can be fabricated through the modified microfabrication process without any help of cleanroom facilities. In comparison with FEA simulation and commercial conductivity device, measured results showed that the fabricated liquid conductivity sensor was able to measure a wide range of liquids. Considering the ease of fabrication and its low cost, the cleanroom-free fabricated sensors have much potential for water quality monitoring.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00542-015-2544-1/MediaObjects/542_2015_2544_Fig1_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00542-015-2544-1/MediaObjects/542_2015_2544_Fig2_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00542-015-2544-1/MediaObjects/542_2015_2544_Fig3_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00542-015-2544-1/MediaObjects/542_2015_2544_Fig4_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00542-015-2544-1/MediaObjects/542_2015_2544_Fig5_HTML.gif)
Similar content being viewed by others
References
Ayers RS, Westcot DW (1976) Water quality for agriculture
Banna MH, Najjaran H, Sadiq R et al (2014) Miniaturized water quality monitoring pH and conductivity sensors. Sens Actu Chem 193:434–441. doi:10.1016/j.snb.2013.12.002
Bolstad PV, Swank WT (1997) Cumulative impacts of landuse on water quality in a southern appalachian watershed. JAWRA J Am Water Resour Assoc 33:519–533. doi:10.1111/j.1752-1688.1997.tb03529.x
Fougere AJ (2000) New non-external field inductive conductivity sensor (NXIC) for long term deployments in biologically active regions. Ocean 2000 MTS/IEEE Conf Exhib Conf Proc (Cat No00CH37158) 1:623–630. doi:10.1109/OCEANS.2000.881324
Glawdel T, Elbuken C, Lee LEJ, Ren CL (2009) Microfluidic system with integrated electroosmotic pumps, concentration gradient generator and fish cell line (RTgill-W1)—towards water toxicity testing. Lab Chip 9:3243–3250. doi:10.1039/b911412m
Hyldgård A, Mortensen D, Birkelund K et al (2008) Autonomous multi-sensor micro-system for measurement of ocean water salinity. Sens Actu Phys 147:474–484. doi:10.1016/j.sna.2008.06.004
King PH, Jones G, Morgan H et al (2014) Interdroplet bilayer arrays in millifluidic droplet traps from 3D-printed moulds. Lab Chip 14:722–729. doi:10.1039/c3lc51072g
Lefèvre F, Chalifour A, Yu L et al (2012) Algal fluorescence sensor integrated into a microfluidic chip for water pollutant detection. Lab Chip 13:787–793. doi:10.1039/c2lc20998e
Li W, Liu FY, Wang KY, Wen ZY (2011) The fabrication and experiment of a four-electrode conductivity sensor for fresh water. Key Eng Mater 483:341–344. doi:10.4028/www.scientific.net/KEM.483.341
Pye VI, Patrick R (1983) Ground water contamination in the United States. Science 80(221):713–718. doi:10.1126/science.6879171
Ramos PM, Pereira JMD, Member S et al (2008) A four-terminal water-quality-monitoring conductivity sensor. Instrum Meas IEEE Trans 57:577–583. doi:10.1109/TIM.2007.911703
Rozemeijer JC, Broers HP (2007) The groundwater contribution to surface water contamination in a region with intensive agricultural land use (Noord-Brabant, The Netherlands). Environ Pollut 148:695–706. doi:10.1016/j.envpol.2007.01.028
Shrestha S, Kazama F (2007) Assessment of surface water quality using multivariate statistical techniques: a case study of the Fuji river basin, Japan. Environ Model Softw 22:464–475. doi:10.1016/j.envsoft.2006.02.001
Van der Pauw LJ (1958) A method of measuring the resistivity and Hall coefficient on lamellae of arbitrary shape. Philips Tech Rev 20:220–224. doi:537.723.1:53.081.7+538.632:083.9
Author information
Authors and Affiliations
Corresponding author
Additional information
Z. Wang and R. Samanipour contributed equally to this work.
Rights and permissions
About this article
Cite this article
Wang, Z., Samanipour, R. & Kim, K. The cleanroom-free rapid fabrication of a liquid conductivity sensor for surface water quality monitoring. Microsyst Technol 22, 2273–2278 (2016). https://doi.org/10.1007/s00542-015-2544-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00542-015-2544-1