Validation of inflationary non-invasive blood pressure monitoring in adult surgical patients

  • Short Communication
  • Published:
Journal of Anesthesia Aims and scope Submit manuscript

Abstract

Oscillometric determination of blood pressure may be advantageous, as cuff inflation requires lower cuff pressure and shorter duration than deflation. In this observational study, we compared the blood pressure value, cuff pressure, and duration of cuff inflation between a prototype of inflationary non-invasive blood pressure (NIBP) and conventional deflationary NIBP in adult patients during anesthesia. Three hundred and twenty-three pairs of measurements were obtained from 64 subjects. The bias and precision of systolic pressure and diastolic pressure were 2.9 ± 8.3 and 5.6 ± 6.1 mmHg, respectively. Inflationary NIBP could better determine NIBP with lower cuff pressure than deflationary NIBP (124 ± 22 vs. 160 ± 33 mmHg, p < 0.05). Inflationary NIBP could also determine NIBP more quickly (13.0 ± 2.3 vs. 32.7 ± 13.6 s, p < 0.05). These data suggest that inflationary NIBP may reduce cuff-related discomfort and complications, and has reasonable accuracy compared to deflationary NIBP in adult surgical patients.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

References

  1. Weiss BM, Pasch T. Measurement of systemic arterial pressure. Curr Opin Anaesthesiol. 1997;10:459–66.

    Article  Google Scholar 

  2. van Montfrans GA. Oscillometric blood pressure measurement: progress and problems. Blood Press Monit. 2001;6:287–90.

    Article  PubMed  Google Scholar 

  3. Bickler PE, Schapera A, Bainton CR. Acute radial nerve injury from use of an automatic blood pressure monitor. Anesthesiology. 1990;73:186–8.

    Article  CAS  PubMed  Google Scholar 

  4. Sutin KM, Longaker MT, Wahlander S, Kasabian AK, Capan LM. Acute biceps compartment syndrome associated with the use of a noninvasive blood pressure monitor. Anesth Analg. 1996;83:1345–6.

    Article  CAS  PubMed  Google Scholar 

  5. Golara M, Jones C, Randhawa M, Shennan AH. Inflationary oscillometric blood pressure monitoring: validation of the OMRON-MIT. Blood Press Monit. 2002;7:325–8.

    Article  PubMed  Google Scholar 

  6. Golara M, Benedict A, Jones C, Randhawa M, Poston L, Shennan AH. Inflationary oscillometry provides accurate measurement of blood pressure in pre-eclampsia. BJOG. 2002;109:1143–7.

    Article  PubMed  Google Scholar 

  7. Munkhaugen J, Lydersen S, Wideroe TE, Hallan S. Blood pressure reference values in adolescents: methodological aspects and suggestions for Northern Europe tables based on the Nord-Trondelag Health Study II. J Hypertens. 2008;26:1912–8.

    Article  CAS  PubMed  Google Scholar 

  8. de Greeff A, Beg Z, Gangji Z, Dorney E, Shennan AH. Accuracy of inflationary versus deflationary oscillometry in pregnancy and preeclampsia: OMRON-MIT versus OMRON-M7. Blood Press Monit. 2009;14:37–40.

    Article  PubMed  Google Scholar 

  9. Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, Jones DW, Kurtz T, Sheps SG, Roccella EJ. Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension. 2005;45:142–61.

    CAS  PubMed  Google Scholar 

  10. Manual, electronic or automated sphygmomanometers. Arlington, VA: American National Standards Institutes, Inc./Association for the Advancement of Medical Instrumentation; 2002 (SP10).

  11. Pickering TG. What will replace the mercury sphygmomanometer? Blood Press Monit. 2003;8:23–5.

    Article  PubMed  Google Scholar 

Download references

Conflict of interest

The study was partly supported by an unrestricted research grant from Nihon Koden.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoshifumi Kotake.

About this article

Cite this article

Onodera, J., Kotake, Y., Fukuda, M. et al. Validation of inflationary non-invasive blood pressure monitoring in adult surgical patients. J Anesth 25, 127–130 (2011). https://doi.org/10.1007/s00540-010-1067-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00540-010-1067-2

Keywords

Navigation