Abstract
Purpose
Arterial cannulation is a common intervention in anesthesia practice. However, the success rates and complications of radial arterial cannulation with 20-G or smaller catheters in patients with atherosclerosis have been underevaluated. The aim of this prospective randomized study was to compare the efficacy of and complications with 20- and 22-G catheters for radial arterial cannulation in atherosclerotic patients.
Methods
Thirty patients with atherosclerosis, American Society of Anesthesiologists (ASA) III–IV, undergoing general anesthesia were enrolled in the study. Radial artery cannulation was performed in group 20G (n = 15) with a 20-gauge (20 × 1.1 × 33 mm; flow, 61 ml·min−1) catheter and in group 22G (n = 15) with a 22-gauge (22 × 0.9 × 25 mm; flow, 36 ml·min−1) catheter. Radial artery systolic blood flow (SBF) and radial artery diameter (RAD) were assessed by a Doppler ultrasound probe before cannulation and 24 h after decannulation for vascular complications. The number of puncture attempts, arterial blood gas samples, and manual flushes; total heparinized solution consumption; duration of cannulation; decannulated radial arterial systolic blood flow; postcannulation RAD; and vascular complications such as occlusion, hematoma, pseudoaneurysm, bleeding, and thrombosis were noted. The Mann Whitney U-test, χ2 test, and one-sample t-test were used. Values are expressed as medians and quartiles and P < 0.05 was considered as significant.
Results
The number of puncture attempts was greater in group 20G (range, 1 to 4) than in group 22G (range, 1 to 2; P = 0.02). In group 20G patients, postoperative RAD was larger than preoperative RAD (P = 0.02) and postoperative SBF was lower than preoperative SBF (P = 0.03). In group 22G patients postoperative SBF was higher than preoperative SBF (P = 0.03), while there was no significant difference between preoperative and postoperative RAD. The occlusion rate of atherosclerotic radial arteries was 6% with the 22-gauge catheter and 26% with the 20-gauge catheter (P = 0.02).
Conclusion
A 22-gauge catheter for radial arterial cannulation in patients with atherosclerosis provides unchanged postcannulated radial artery diameter, decreases postcannulation complications, and improves the first-attempt success rate.
Similar content being viewed by others
References
Wilkins RG. Radial artery cannulation and ischemic damage: a review. Anaesthesia. 1985;40:896–899.
Martin C, Saux P, Papazian L, Gouin F. Long-term arterial cannulation in ICU patients using the radial artery or dorsalis pedis artery. Chest. 2001;119:901–906.
Rigatelli G, Magro B, Maronati L, Tranquillo M, Oliva L, Panin S, Bedendo E. An improved technique for gaining radial artery access in endovascular interventions. Cardiovasc Revasc Med. 2006;7:46–47.
MacKay AJ, Hamilton CA, McArthur K, Berg G, Tropeano A. Radial artery hypertrophy occurs in coronary atherosclerosis and is independent of blood pressure. Clin Sci. 2001;100:509–516.
Bedford RF. Radial arterial function following percutaneous cannulation with 18- and 20- gauge catheters. Anesthesiology. 1977;47:37–39.
Bazemore E, Mann JT. Problems and complications of the transradial approach for coronary interventions: a review. J Invasive Cardiol. 1999;83:180–186.
Scheer BV, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care. 2002;6:198–209.
Giannattasio C, Mangoni AA, Failla M, Carugo S, Stella ML, Stefanoni P, Grassi G, Vergani C, Mancia G. Impared radial artery compliance in normotensive subjects with familial hypercholesterolemia. Atherosclerosis. 1996;124:249–260.
Mangar D, Thrush DN, Connell R, Downes JB. Direct or modified Seldinger guide wire-directed technique for arterial catheter insertion. Anesth Analg. 1993;76:714–717.
Milnor WR. Properties of the vascular wall. In: Collins N, editor. Hemodynamics, 2nd ed. Baltimore: Williams & Wilkins; 1982. p. 95–101.
Karacalar S, Ture H, Baris S, Karakaya D, Sarihasan B. Ulnar artery versus radial artery approach for arterial cannulation: a prospective, comparative study. J Clin Anesth. 2007;19:209–213.
Allen EV, Baker NW, Hines EA. Peripheral vascular disease. 3rd ed. Philadelphia: WB Saunders; 1962. chapter XI.
Saito S, Ikei H, Hosokawa G, Tanaka S. Influence of the ratio between radial artery inner diameter and sheath outer diameter on radial artery flow after transradial coronary intervention. Cathet Cardiovasc Intervent. 1999;46:173–178.
Author information
Authors and Affiliations
About this article
Cite this article
Evren Eker, H., Tuzuner, A., Yilmaz, A.A. et al. The impact of two arterial catheters, different in diameter and length, on postcannulation radial artery diameter, blood flow, and occlusion in atherosclerotic patients. J Anesth 23, 347–352 (2009). https://doi.org/10.1007/s00540-009-0753-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00540-009-0753-4