Skip to main content
Log in

Diagnostic sensitivity of serum cystatin for impaired glomerular filtration rate

  • ORIGINAL ARTICLE
  • Published:
Pediatric Nephrology Aims and scope Submit manuscript

Abstract 

Recently, the reciprocal of cystatin C (Cys-C), a non-glycosylated 13-kilodalton protein that is produced by all investigated nucleated cells, was found to correlate closely with glomerular filtration rate (GFR). In order to determine the diagnostic validity in children for the detection of impaired GFR, venous blood samples from 381 children (aged 1.7–18 years) with various renal pathology referred for 51Cr-EDTA clearance investigations were obtained for measurement of Cys-C as well as β2-microglobulin (β2-MG) and serum creatinine. Two hundred and sixteen children with clearance values >90 ml/min per 1.73 m2 constituted a control group, with a normal GFR. In the control group, Cys-C values were normally distributed with a mean of 0.94±0.27 mg/l and an upper reference limit (97.5th percentile) of 1.47 mg/l. In all children, there was a positive correlation between 51Cr-EDTA clearance and the reciprocal of Cys-C (r=0.64, P<0.0001), β2-MG (r=0.59, P<0.0001), creatinine (r=0.55, P<0.0001), and the height/creatinine ratio (r=0.73, P<0.0001). Receiver-operating characteristics analysis showed that there were no significant differences between these three parameters for discriminating between patients with normal and reduced GFR, although there was a tendency towards the best diagnostic sensitivity of the GFR estimate according to the Schwartz formula. We conclude that for the detection of mildly impaired GFR, a full clearance study cannot be replaced by measurement of serum Cys-C or β2-MG concentrations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 15 June 1998 / Revised: 22 September 1998 / Accepted: 23 September 1998

Rights and permissions

Reprints and permissions

About this article

Cite this article

Filler, G., Priem, F., Vollmer, I. et al. Diagnostic sensitivity of serum cystatin for impaired glomerular filtration rate. Pediatr Nephrol 13, 501–505 (1999). https://doi.org/10.1007/s004670050646

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004670050646

Navigation