Skip to main content
Log in

Effects of carbon dioxide vs helium pneumoperitoneum on hepatic blood flow

  • Published:
Surgical Endoscopy Aims and scope Submit manuscript

Abstract

Background: Elevated intraabdominal pressure due to gas insufflation for laparoscopic surgery may result in regional blood flow changes. Impairments of hepatic, splanchnic, and renal blood flow during peritoneal insufflation have been reported. Therefore we set out to investigate the effects of peritoneal insufflation with helium (He) and carbon dioxide (CO2) on hepatic blood flow in a porcine model.

Methods: Twelve pigs were anesthetized and mechanically ventilated with a fixed tidal volume after the stabilization period. Peritoneal cavity was insufflated with CO2 (n= 6) or He (n= 6) to a maximum intraabdominal pressure of 15 mmHg. Hemodynamic parameters, gas exchange, and oxygen content were studied at baseline, 90 mm and 150 min after pneumoperitoneum, and 30 min after desufflation. Determination of hepatic blood flow with indocyanine green was made at all measured points by a one-compartment method using hepatic vein catheterization.

Results: A similar decrease in cardiac output was observed during insufflation with both gases. Hepatic vein oxygen content decreased with respect to the baseline during He pneumoperitoneum (p < 0.05), but it did not change during CO2 insufflation. Hepatic blood flow was significantly reduced in both the He and CO2 pneumoperitoneums at 90 min following insufflation (63% and 24% decrease with respect to the baseline; p < 0.001 and p < 0.05, respectively) being this decrease marker in the He group (p= 0.02).

Conclusions: These findings suggest that helium intraperitoneal insufflation results in a greater impairment on hepatic blood flow than CO2 insufflation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 27 March 1996/Accepted: 19 January 1997

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sala-Blanch, X., Fontanals, J., Martínez-Palli, G. et al. Effects of carbon dioxide vs helium pneumoperitoneum on hepatic blood flow. Surg Endosc 12, 1121–1125 (1998). https://doi.org/10.1007/s004649900797

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004649900797

Navigation