Laparoscopically assisted ventriculoperitoneal shunt placement using 2-mm instrumentationrid=""id=""Presented in poster format at the annual meeting of the Society of American Gastrointestinal Endoscopic Surgeons (SAGES), San Antonio, Texas, USA, 24–27 March 1999

  • Published:
Surgical Endoscopy Aims and scope Submit manuscript

Abstract

Background: Laparoscopy has potential benefit in the placement of ventriculoperitoneal shunts. In patients who have undergone multiple shunt revisions or other abdominal operations, laparoscopy may be particularly beneficial when finding of a suitable area in which to place the shunt is a concern. The purpose of this study was to evaluate the safety and effectiveness of laparoscopically assisted ventriculoperitoneal shunt placement, with an emphasis on using 2-mm instrumentation.

Methods: Laparoscopically assisted ventriculoperitoneal shunt placement using 2-mm instrumentation was performed in eight adult hydrocephalus patients from August 1996 to September 1998. All eight patients had undergone 1 to 18 prior shunt revisions. The procedures were performed with two 2-mm trocars. The instrumentation consisted of a 2-mm laparoscope, a 2-mm grasper, and 2-mm scissors. All shunts were placed in an area free of adhesions and checked for flow under direct vision. Four of the patients required a lysis of adhesions to create a space adequate for catheter placement.

Results: All of the procedures were successful, with no operative complications. The operative times ranged from 29 to 99 min, (mean, 63 min). The blood loss in all of the procedures was minimal. At this writing, none of the patients have required subsequent distal shunt revisions. No conversions to larger instruments or an open procedure were required.

Conclusions: Laparoscopically assisted ventriculoperitoneal shunt placement using 2-mm instrumentation is safe and effective, offering several advantages over the open procedure. This procedure is ideal for the use of 2-mm instruments.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 19 March 1999/Accepted: 23 June 1999/Online publication: 10 April 2000

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Reardon, P., Scarborough, T., Matthews, B. et al. Laparoscopically assisted ventriculoperitoneal shunt placement using 2-mm instrumentationrid=""id=""Presented in poster format at the annual meeting of the Society of American Gastrointestinal Endoscopic Surgeons (SAGES), San Antonio, Texas, USA, 24–27 March 1999. Surg Endosc 14, 585–586 (2000). https://doi.org/10.1007/s004640020078

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004640020078

Navigation